pass & seymour TradeMaster Manuals

1 pdf manual(s) pass & seymour TradeMaster for free download (Document Types: Installation instructions)

pass & seymour TradeMaster Installation instructions Thumbnail

pass & seymour TradeMaster Installation instructions [PDF] (2 pages)

  • Identifier: id-1047045
  • Brand: pass & seymour
  • Device: pass & seymour TradeMaster Dimmer
  • Type: Installation instructions, PDF
  • Key Aspects: Performance Optimization Tips, Efficiency and Calibration Tips, Routine Functionality Testing
  • UPD Date: 30.06.2026
  • Source File: 1111405.pdf
  • Pages: 2
  • Description: Setup instructions for the pass & seymour TradeMaster.
Pages Preview:
  • pass & seymour TradeMaster Installation instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
R E A D A N D S A V E T H E S E I N S T R U C T I O N S To be installed by a certified electrician or other qualified person. WARNING – To prevent severe shock or electrocution, always turn power off at the service panel before installing this unit, working on the circuit, or changing a lamp. CAUTION – To reduce the risk of overheating and possible damage to other equipment, do not install incandescent dimmer to control a receptacle, a fluorescent light or bulb, a motor-operated appliance, or a transformer-supplied appliance. Do not use dimmer with incandescent lamps whose power requirements exceeds maxi- mum power (stated in Watts) of the dimmer. Do not connect dimmer to power source other than 120VAC, 60 Hz only. A 50W minimum load is required. Use copper wire only. DIRECTIONS 1. Disconnect power to circuit by removing fuse or turning circuit breakers to OFF before installing. 2. Remove existing wall plate and switch mounting screws. 3. Disconnect existing switch from circuit. 3-way installation: Identify the “Common” wire (wire connected to the terminal marked common or odd colored terminal). For “new” installation identify wire connected to power source or to the load. 4. Strip existing wires using gauge on back of device. 5. Connect dimmer as shown in the wiring and installation diagrams. INSTALLATION DIAGRAMS FOR DIMMERS 6. Install dimmer in wall box, with word ‘TOP’ on metal strap right side up, using mounting screws provided. 7. Attach wall plate. 8. Restore power and follow operating instructions. Note: Protect from dirt and dust. The dimmer can be damaged from contaminates encountered during the construction process. If lighting is required prior to the construction process completion, then a switch should be temporarily installed in place of the dimmer. The dimmer should not be installed until the construction process is complete. OPERATING INSTRUCTIONS: 1. Toggle the switch provided to turn the dimmer ON and OFF. 2. To change lighting level rotate the knob clockwise or counterclockwise until desired level is reached. NOTE: Only a three way switch can be used to operate the light from a second location. Control may feel warm to the touch in normal operation. This control is intended for installation in a U.L. Listed metal or (polymeric) plastic outlet box. MULTIPLE GANGING OF DIMMERS & OTHER DEVICES Any combination of dimmer models and other devices may be ganged together. Break off tabs are provided on the 1100W dimmer straps for multi-gang applications. Pry off the tabs using pliers before installation, as shown in the multi-gang illustration. De-rate the maximum load according to the following table: Light Module: (sold separately, Catalog # TM8LMCC) Transform in minutes a standard dimmer into an illuminated dimmer (ON when light is OFF) – allows the dimmer to be found in the dark. Average 20-year life expectancy. No wiring – quick snap-in installation. Any dimmer damage due to improper installation is not covered under warranty. LIFETIME WARRANTY The device you have purchased is warranted under normal use against defects in workmanship and materials for as long as you own the device. If the device fails due to manufacturing defect during normal use, return the device for replacement to the store where purchased or send to: Pass & Seymour Legrand, 50 Boyd Avenue, Syracuse, NY 13209. All requests for replacement must include a dated sales receipt (legible copies acceptable). ALL OTHER WARRANTIES, INCLUDING BUT NOT LIMITED TO ANY WARRANTIES OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, ARE LIMITED TO A PERIOD OF TWO YEARS FROM THE DATE OF PURCHASE. YOUR SOLE AND EXCLUSIVE REMEDY AGAINST PASS & SEYMOUR LEGRAND UNDER ANY WARRANTY SHALL BE THE EQUIVALENT REPLACEMENT OF THE DEVICE. IN NO EVENT SHALL ANY WARRANTY APPLY TO ANY DEFECT ARISING OUT OF ANY ALTERATION OF THE DEVICE, IMPROPER WIRING, IMPROPER INSTALLATION, MISUSE, ABNORMAL USE OR NEGLIGENCE. IN NO EVENT SHALL PASS & SEYMOUR LEGRAND BE LIABLE FOR LOST PROFITS, INDIRECT, SPECIAL, EXEMPLARY, INCIDENTAL OR CONSEQUENTIAL DAMAGES. Some states do not allow limitations on how long implied warranties last and do not allow exclusion or limitation of incidental or consequential damages. Some of the above limitations or exclusions may not apply to every purchaser. INSTRUCCIONES EN ESPAÑOL L E A Y G U A R D E E S T A S I N S T R U C C I O N E S Para ser instalado por electricista certificado u otra persona capacitada. ADVERTENCIA: Para prevenir una sacudida eléctrica severa o electrocución, siempre CORTE la electricidad en el panel de servicio antes de instalar esta unidad, trabajar en el circuito, o cambiar una lámpara. AVISO: Para evitar el recalentamiento y los posibles daños a otro equipo, no instale este dispositivo para controlar un tomacorriente, una lámpara o tubo fluorescente, un elec- trodoméstico a motor o un electrodoméstico alimentado por un transformador. No use el reductor de luz con lámparas incandescentes cuyas requisitos de potencia exija la potencia máxima (indicada en Wats) del reductor de luz. No conecte al reductor de luz a otra fuente de potencia que no sea solo 120VAC, 60Hz. Una carga mínima de 50W es requerida. Solo utilice cables de cobre. INSTRUCCIONES: 1. Desconecte la corriente del circuito quitando el fusible o APAGANDO los disyuntores antes de instalar. 2. Quite la placa existente y los tornillos de la pared y quite el interruptor. 3. Desconecte del circuito el interruptor existente. Instalación de 3 vías: Identifique el alambre “Común” (alambre conectado a la terminal marcado ‘common/común’ o al terminal de color distinto). Para instalación “nueva”, identifique el alambre conectado al suministro eléctrico o a la carga. 4. Pele el alambre utilizando la guía en la parte trasera del aparato. 5. Conecte el reductor de luz como mostrado en el diagrama de instalación y alambrado. DIAGRAMA DE INSTALACION NEW INSTALLATION INSTRUCTIONS TradeMaster® DECORATOR ROTARY DIMMER P/N 34087500 INSTRUCCIONES DE INSTALACÓN TradeMaster® ATENUADOR GIRATORIO DECORATIVO Screw Pressure Plate Back Wire Securely tighten screw beneath wire hole to retain inserted wire. Insert wire to bottom of hole. Termination takes #12 or #14 AWG stranded or solid, copper conductors. MULTI-GANG DE-RATING DIMMER MAXIMUM 2 GANG 3 GANG CATALOG # LOAD INSTALLATION INSTALLATION DR1103-P_V 1100W 900W 800W DR703-P_V 700W 700W 700W Atornille el Alambre Trasero de la Tapa Presora Apriete el tornillo debajo del hueco del alambre para aguantar el alambre insertado. Introduzca el alambre al hueco del fondo. La terminación acepta conductores trenzados o sólidos #12 o #14 AWG de cobre.

Similar Manuals in the Dimmer Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
AMX RDM-INC

#C5R96J: RDM-INC Dimmer Installation sheet

2 0.51 Mb 45 9 21-07-2026 view all manuals
City Theatrical 5620

City Theatrical 5620 Guide (Operation & user’s manual), @I44Y81

8 750 173 21-08-2026 view all manuals
Lutron Electronics Hi-lume Premier 0.1

Dimmer #QCJ171

14 1149 184 03-08-2026 view all manuals
EVERSPRING AD126

#K6MDL7: AD126 Dimmer Quick start manual

3 401 77 18-06-2026 view all manuals
City Theatrical QolorFLEX

QolorFLEX Quick start manual - 3IY975

4 867 148 09-06-2026 view all manuals
LG AJ-LAH2

AJ-LAH2 Owner's manual - P24VJS

4 611 141 24-03-2026 view all manuals