Pentair MiniMax Plus, PowerMax MiniMax Manuals

3 pdf manual(s) Pentair MiniMax Plus, PowerMax MiniMax for free download (Document Types: Operation & installation manual, Service manual)

Document Preview & Text Transcription

Rev. G 1-22-04 P/N 471048 11 FOR YOUR SAFETY - READ BEFORE OPERATING Warning: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. For additional free copies of this manual; call (800) 831-7133. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances. For Your Safety Warning: Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or death. Installation and service must be performed by a qualified installer, service agency or the gas supplier. MiniMax® Plus and PowerMax™ POOL & SPA HEATERS OPERATION & INSTALLATION MANUAL WARNING WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. WARNING U.S. Patent Numbers 6,295,980 5,318,007 - 5,228,618 5,201,307 - 4,595,825 Pentair Pool Products, Inc. 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 W. Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 1 To Consumer Retain For Future Reference P/N 471048 Rev. G 1-22-04 2 Table of Contents Introduction ............................................................................................................... 3 Important Notices ...................................................................................................................................................................... 3 Warranty Information ................................................................................................................................................................. 4 Operation .................................................................................................................... 4 Safety Rules .............................................................................................................................................................................. 4 Electronic Ignition Lighting/Operation - Natural ......................................................................................................................... 5 Electronic Ignition Lighting/Operation - Propane ....................................................................................................................... 6 Millivolt Lighting/Operation - Natural & Propane ........................................................................................................................ 7 Operating (Controls) .................................................................................................................................................................. 8 Indicator Light Description - Electronic Ignition Model ............................................................................................................... 8 Maintenance ............................................................................................................... 11 Maintenance Instructions........................................................................................................................................................... 11 Relief Valve................................................................................................................................................................................ 11 Energy Saving Tips.................................................................................................................................................................... 11 Spring and Fall Operation.......................................................................................................................................................... 11 Winter Operation ....................................................................................................................................................................... 11 Chemical Balance...................................................................................................................................................................... 12 Installation Instructions ............................................................................................ 13 Specifications .......................................................................................................................... 13 Water Connections.................................................................................................................. 14 Reverse Water Connections ...................................................................................................................................................... 14 Plumbing/Plumbing Connections ............................................................................................................................................... 14 Manual Bypass .......................................................................................................................................................................... 14 Below Pool Installation .............................................................................................................................................................. 14 Quick Flange Installation ........................................................................................................................................................... 15 Gas Connections..................................................................................................................... 16 Gas Line Installation .................................................................................................................................................................. 16 Pipe Sizing Chart/Gas Pressure Requirements ......................................................................................................................... 16 Regulated Manifold Pressure Test ............................................................................................................................................. 16 Ventilation ................................................................................................................................ 17 Outdoor Installation Requirements ............................................................................................................................................ 17 Outdoor Cap Installation ............................................................................................................................................................ 17 Indoor Installation Requirements ............................................................................................................................................... 18 Installation on Floors Constructed of Combustible Materials ..................................................................................................... 19 Indoor Draft Hood Installation .................................................................................................................................................... 20 Electrical .................................................................................................................................. 20 Transformer Wiring Instruction .................................................................................................................................................. 20 Electrical Wiring Diagram .......................................................................................................................................................... 21 Remote Control Wiring .............................................................................................................................................................. 22 Trouble Shooting (General)....................................................................................... 23 MiniMax Plus Parts List & Exploded View ............................................................... 24-26 PowerMax Appendix .................................................................................................. A1-A9 PowerMax Parts List & Exploded View .................................................................... A10-A13 Warranty Information ................................................................................................. Back Cover Rev. G 1-22-04 P/N 471048 3 MiniMax® Plus and PowerMax™* Pool and Spa Heaters Congratulations on your purchase of a MiniMax Plus high performance heating system. Proper installation and service of your new heating system and correct chemical maintenance of the water will ensure years of enjoyment. The MiniMax Plus is a compact, lightweight and efficient gas fired high performance pool and spa heater that can be directly connected to schedule 40 PVC pipe and has a built-in top. The MiniMax Plus, also comes equipped with PurexTriton’s nine function indicator lights (electronic ignition only) which show, at a glance, the proper functioning of the heater. All electronic ignition MiniMax Plus heaters are designed with an intermittent ignition device (IID) which eliminates the need for a standing pilot. The electronic ignition MiniMax Plus requires is an external power source (120 VAC or 240 VAC) 50/60 Hz to operate. The millivolt MiniMax Plus has a self sustaining pilot and requires NO external power source. All MiniMax and PowerMax pool and spa heaters are year 2000 compliant. *Unless noted otherwise, any references to the MiniMax Plus include the PowerMax (Induced Draft) models. The wiring and venting of the PowerMax is covered in an appendix to this manual. IMPORTANT NOTICES ...For the installer and operator of the MiniMax Plus pool and spa heater. The manufacturer’s warranty may be void if, for any reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual. If you need any more information, or if you have any questions regarding to this pool heater, please contact Pentair Pool Products, Inc. at (800) 831-7133. These heaters are designed for the heating of swimming pools and spas, and should never be employed for use as space heating boilers, general purpose water heaters, in non-stationary installations, or for the heating of salt water. CAUTION OPERATING THIS HEATER CONTINUOUSLY AT WATER TEMPERATURE BELOW 68° F. WILL CAUSE HARMFUL CONDENSATION AND WILL DAMAGE THE HEATER AND WILL VOID THE WARRANTY. Do not use the heater to protect pools or spas from freezing if the final maintenance temperature desired is below 68° F. as this will cause condensation related problems. CODE REQUIREMENTS The installation must conform with local codes or in the absence of local codes with the latest National Fuel Gas Code, ANSI Z223.1, and the latest edition of the National Electrical Code, NFPA 70. Installation in Canada to be made in accordance with the latest CAN/CGA-B149.1 or .2 and CSA C22.1 Canadian Electric Code, part 1. Introduction
Pentair MiniMax Plus, PowerMax MiniMax Service manual Main Page Preview

Service manual [PDF] (40 pages)

  • Updated: 31.08.2026

Document Preview & Text Transcription

1 Rev. C 12-1-00 P/N 38033 FOR YOUR SAFETY - READ BEFORE OPERATING Warning: If you do not follow these instructions exactly, a fire or explosion may result, causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or other appliances. For Your Safety Improper installation, adjustment, alteration, service or maintenance can cause property damage, personal injury or death. Installation and service must be performed by a qualified installer, service agency or the gas supplier. MiniMax Plus POOL & SPA HEATERS SERVICE MANUAL WARNING WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a neighbor's phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. WARNING Pentair Pool Products 1620 Hawkins Ave., Sanford, NC 27330 • (919) 774-4151 10951 West Los Angeles Ave., Moorpark, CA 93021 • (805) 523-2400 2 P/N 38033 Rev. C 12-1-00 Table of Contents Introduction ............................................................................................................... 3 Important Notices .......................................................................................................................................................................... 3 Safety Rules .................................................................................................................................................................................. 3 Installation Tips .......................................................................................................... 4 Dimensions .............................................................................................................................. 5 Outdoor Installation Requirements ................................................................................................................................................ 6 Water Connections ................................................................................................................. 7 Reversing Header Connections .................................................................................................................................................... 8 Air Requirements .......................................................................................................................................................................... 9 Vent Requirements ........................................................................................................................................................................ 9 Gas Connections .................................................................................................................... 10 Gas Line/Installation ...................................................................................................................................................................... 10 Pipe Sizing Chart/Gas Pressure Requirements ............................................................................................................................. 10 Electrical .................................................................................................................................. 11 Transformer Wiring Instruction ...................................................................................................................................................... 11 Remote Control Wiring .................................................................................................................................................................. 11 Electrical Wiring Schematic ............................................................................................................................................................ 12 Electrical Wiring Pictorial ................................................................................................................................................................ 13 Operation .................................................................................................................... 14 Millivolt Lighting/Operation - Natural & Propane ............................................................................................................................ 14 Chemical Balance .......................................................................................................................................................................... 15 Maintenance ............................................................................................................... 16 Spring and Autumn Operation ....................................................................................................................................................... 16 Winter Operation ........................................................................................................................................................................... 16 Burner Tray Removal .................................................................................................................................................................... 17 Desooting ...................................................................................................................................................................................... 18 Reinstalling Heat Exchanger ......................................................................................................................................................... 19 Glossary...................................................................................................................... 20 Troubleshooting......................................................................................................... 21-32 Electrical Wiring Diagram .............................................................................................................................................................. 33 Millivolt Wiring Diagram ................................................................................................................................................................. 34 Test and Adjustments ................................................................................................ 35 MiniMax Plus Exploded View & Parts List............................................................... 36-38 Warranty Information ................................................................................................. Back Cover 3 Rev. C 12-1-00 P/N 38033 MiniMax Plus Pools and Spa Heater ...For the installer and operator of the MiniMax Plus pool and spa heater. The manufacturer’s warranty may be void if, for any reason, the heater is improperly installed and/or operated. Be sure to follow the instructions set forth in this manual. These heaters are designed for the heating of swimming pools and spas, and should never be employed for use as space heating boilers, general purpose water heaters, in non-stationary installations, or for the heating of salt water. CODES The installation must conform with local codes or in the absence of local codes with the latest National Fuel Gas Code, ANSI Z223.1, and the latest edition of the National Electrical Code, NFPA 70. Installation in Canada to be made in accordance with the latest CAN/CGA-B149.1 or .2 and CSA C22.1 Canadian Electric Code, part 1. Important Notice Safety Rules 1. Spa or hot tub water temperatures should never exceed 104° F (40° C). A temperature of 100° F (38° C) is considered safe for a healthy adult. Special caution is suggested for young children. 2. Drinking of alcoholic beverages before or during spa or hot tub use can cause drowsiness which could lead to unconsciousness and subsequently result in drowning. 3. Pregnant women beware! Soaking in water above 102° F (39° C) can cause fetal damage during the first three months of pregnancy (resulting in the birth of a brain-damaged or deformed child). Pregnant women should stick to the 100° F (38° C) maximum rule. Should overheating occur or the gas supply fail to shut off, turn off the manual gas control valve to the appliance. Do not use this heater if any part has been under water. Immediately call a qualified service technician to inspect the heater and to replace any part of control system and gas control which has been under water. WARNING 4. Before entering the spa or hot tub, the user should check the water temperature with an accurate thermometer. Spa or hot tub thermostats may err in regulating water temperatures by as much as 4° F (2.2° C). 5. Persons with a medical history of heart disease, circulatory problems, diabetes or blood pressure problems should obtain their physician's advice before using spas or hot tubs. 6. Persons taking medication which induce drowsiness, such as tranquilizers, antihistamines or anticoagulants should not use spas or hot tubs. 4 P/N 38033 Rev. C 12-1-00 Installation Tips �� �� �� �� ������� ����� ����� ����� ����� DO NOT INSTALL HEATER UNDER ANY ROOF OVERHANG NOT HAVING A PROPER RAIN GUTTER. CA CA CA CA CAUTION UTION UTION UTION UTION DO NOT PLACE GAS SUPPLY LINE UNION COUPLING INSIDE OF HEATER JACKET. (Follow Recommendations of National Fuel Gas Code NFPA 54.) CA CA CA CA CAUTION UTION UTION UTION UTION DO NOT RESTRICT ACCESS TO HEATER WITH PIPING.