Pentair MT Sizes 500 Manuals

1 pdf manual(s) Pentair MT Sizes 500 for free download (Document Types: Installation and operation instructions manual)

Document Preview & Text Transcription

Model MT Sizes 500 - 1825 IMPORTANT: Store these instructions in the pocket provided on the heater Installation and Operation Instructions for MegaTherm Pool Heating Boiler WARNING If the information in this manual is not followed exactly, a fire or explosion may result causing property damage, personal injury or loss of life. Do not store or use gasoline or other flammable vapors and liquids in the vicinity of this or any other appliance. WHAT TO DO IF YOU SMELL GAS • Do not try to light any appliance. • Do not touch any electrical switch; do not use any phone in your building. • Immediately call your gas supplier from a nearby phone. Follow the gas supplier's instructions. • If you cannot reach your gas supplier, call the fire department. Installation and service must be performed by a qualified installer, service agency, or gas supplier. FOR YOUR SAFETY: This product must be installed and serviced by a professional service technician, qualified in hot water boiler installation and maintenance. Improper installation and/or operation could create carbon monoxide gas in flue gases which could cause serious injury, property damage, or death. Improper installation and/or operation will void the warranty. AVERTISSEMENT Assurez-vous de bien suivres les instructions données dans cette notice pour réduire au minimum le risque d’incendie ou d’explosion ou pour éviter tout dommage matériel, toute blessure ou la mort. Ne pas entreposer ni utiliser d’essence ni d’autres vapeurs ou liquides inflammables dans le voisinage de cet appareil ou de tout autre appareil. QUE FAIRE SI VOUS SENTEZ UNE ODEUR DE GAZ: • Ne pas tenter d’allumer d’appareils. • Ne touchez à aucun interrupteur. Ne pas vous servir des téléphones dansle bâtiment où vous vous trouvez. • Appelez immédiatement votre fournisseur de gaz depuis un voisin. Suivez les instructions du fournisseur. • Si vous ne pouvez rejoindre le fournisseur de gaz, appelez le sservice des incendies. L’installation et l’entretien doivent être assurés par un installateur ou un service d’entretien qualifié ou par le fournisseur de gaz. P/N 472643 Rev A - 05/22/06 IMPORTANT SAFETY INSTRUCTIONS READ AND FOLLOW ALL INSTRUCTIONS SAVE THESE INSTRUCTIONS ® TM Pentair Water Commercial Pool and Spa Page 2 TABLE OF CONTENTS SECTION 1. General Information 1.1 Introduction................................................... 3 1.2 Heater Identification ..................................... 3 1.3 Primary/Secondary Pump and Piping........... 3 1.4 Certifications................................................. 3 1.5 Engineering Assistance ................................ 3 SECTION 2. Installation 2.1 Boiler Placement .......................................... 4 2.2 Installation of Indoor Boilers ......................... 4 2.2.1 Combustion Air Supply ................................. 4 2.2.2 Venting ......................................................... 5 2.2.3 Common Venting System Test Procedure ............................................. 6 2.2.3 Instructions Relatives au Test des Systèmes à Évent Commun ......................... 6 2.3 Installation of Outdoor Boilers ...................... 7 2.4 Gas Supply and Piping ................................. 7 2.5 Electrical Wiring............................................ 8 2.6 General Piping Instructions .......................... 9 2.7 Boiler By-Pass Piping ................................... 9 2.8 Temperature Sensor Placement and Installation ............................................ 10 2.9 Automatic Chlorinators ............................... 10 SECTION 3. Operation 3.1 Controls - General ...................................... 11 3.2 Initial Start-Up............................................. 11 3.3 Safety Shutoff Component Checkout ......... 12 3.4 Inlet Temperature and Temperature Rise Adjustment .................... 12 3.5 Heater Shut Down ...................................... 13 3.6 Spring and Fall Operation Stand-by Service ........................................ 13 3.7 Winter Operation Complete Shutdown ....... 14 3.8 Time Clock Operation................................. 14 3.9 Therapeutic Pools (Spas) ........................... 14 SECTION 4. Maintenance..............................................15 SECTION 5. Troubleshooting .......................................16 SECTION 6. Parts Description and Order Numbers ................ 17 Pentair Technical Support Sanford, North Carolina (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: (919) 566-8920 Moorpark, California (8 A.M. to 5 P.M.) Phone: (800) 831-7133 Fax: (800) 284-4151 Web sites: visit www.pentairpool.com and www.staritepool.com MegaTherm Commercial Pool Heating Boiler Page 3 SECTION 1. General Information 1.1 Introduction This manual provides information for the installation and operation of MegaTherm model MT pool heating boilers. It is strongly recommended that all application and installation procedures be reviewed completely before proceeding with the installation. Consult Pentair Commercial Pool and Spa, or your local sales representative, with any problems or questions regarding this equipment. Experience has shown that most problems are caused by improper installation, not system design. Some accessory items are shipped in separate packages. Verify receipt of all packages listed on the packing slip. Inspect everything for possible damage upon delivery, and inform the carrier of any shortages or impairments. Any such claims should be filed with the carrier. The carrier, not the shipper, is responsible for shortages and damage to the shipment whether visible or concealed. The warranty does not apply to heaters not installed or operated in accordance with these procedures. Consult local building and safety codes before proceeding with work. The installation must conform to the requirements of the authority having jurisdiction or, in the absence of such requirements, to the latest edition of the National Fuel Gas Code; ANSI Z223.1, National Electrical Code ANSI/NFPA 70. In Canada, the installation must conform with the latest edition of CSA-B149.1 requirements. When required by the authority having jurisdiction, the installation must conform to Figure 1. Heater Identification (model nomenclature). WARNING The MegaTherm model MT commercial pool heating boiler must be used on potable water only. For heating pools containing salt water, a specially equipped heater must be used; consult your distributor or factory representative. The pool heating boiler must be installed in accordance with the procedures MODEL MT-POOL REVISION P-PUMP (U.S.) Q-PUMP (CAN) HEAT EXCHANGER C-GLASS LINED/COPPER N-GLASS LINES/CU-NI K-BRONZE/COPPER S-BRONZE/CU-NI VERSION 1 - 8 TUBE B-10 TUBE I-INDOOR E-OUTDOOR FUEL N-NATURAL P-PROPANE IGNITION 04-SPARK 110V 09-SPARK 24V 11-SPARK 24V 16-STND. PILOT SIZE BTU/HR X 1000 0500 0600 0715 0850 0999 1010 1200 1430 1670 1825 C FIRING MODE ON/OFF 1 2 3 4 5 6 7 8 9 10 11 12 13 14 American Society of Mechanical Engineers safety codes for controls and safety devices for automatically fired heaters No. CSD-1, and in Canada CGA 3.3. Any modification of the heater, its gas controls, gas orifices, wiring or drafter diverter may void the warranty. If field conditions require such modifications, consult factory. 1.2 Heater Identification Consult rating plate on the heating boiler. Shown below is a breakdown of the model nomenclature. Commercial pool heating boilers are available in two configurations: an indoor version and an outdoor version. Outdoor models are not available in Canada. 1.3 Primary/Secondary Pump and Piping All models are supplied with integrally mounted pumps. The 1825 models use a 3/4 HP pump and all other models are supplied with 1/2 HP pumps. These pumps are sized for the pressure drop through the heat exchanger and through the bypass piping as shown in Figure 10. Any deviations from the arrangement shown may increase the head on the pump, reduce flow and hinder performance (see Section 2.7). For spas see Section 3.9. This piping arrangement and the integral pump allow hot water to be recirculated to the heater inlet, thus raising the inlet temperature and greatly reducing condensation. 1.4 Certifications All models are design-certified by CSA for natural or propane gas and conform to ASME Code requirement for 160 PSI water pressure. 1.5 Engineering Assistance Consult the factory or distributor regarding any questions or problems which arise in the specification, installation or operation of this equipment. An experienced engineering staff is ready to assist in assuring the proper performance and application of this products. Pentair Water Commercial Pool and Spa Page 4 SECTION 2. Installation 2.1 Boiler Placement The pool heating boiler must be placed to provide specific clearances on all sides for maintenance and inspections. There must also be minimum distances maintained from combustible surfaces. These clearances also apply to noncombustible materials because the pool heating boiler requires air circulation for proper operation. The pool heating boiler should be mounted on a level surface. An integral base for an installation on combustible flooring is provided as standard equipment on outdoor models. For indoor models, special base rails part number 10539000 must be used for combustible flooring. Do not install a pool heating boiler on carpeting. Under the national Fuel Gas Code, ANSI Z223.1, it is permissible to place the boiler on floors other than noncombustible when the installation complies with the American Insurance Code. Figures 2, 3, 4 and 5 show common installation on combustible flooring. 2.2 Installation of Indoor Boilers Locate the pool heating boiler to provide adequate clearance for inspection and service on all sides. See Table 1. For alcove installation, see Figure 6. Install indoor heaters on a waterproof floor with an adequate floor drain and a 6" (152mm) minimum curb on all four sides to protect the building if heater repairs are required. The manufacturer will not be held liable for any water damage in connection with this boiler. 2.2.1 Combustion Air Supply The heater location must provide sufficient air supply for proper combustion and ventilation of the surrounding area as outlined in the latest edition of ANSI standard Z223.1, and any local codes that may be applicable. Inadequate combustion air supply may result in incomplete combustion, sooting of the heat exchanger, and unsafe operation of the boiler. a. Conventional Ventilation In the United States, the most common of these requirements specify that boiler rooms should be provided with two permanent air supply openings communicating directly through the wall to outside air one within 12 inches (305mm) of the ceiling, and the other within 12 inches (305mm) of the floor. Each opening should have a minimum free area of one square inch (6.5 sq. cm) per 4,000 BTU/hr input of the total input rating of all appliances in the enclosed area. See Table 2 for recommended air supply for each model. An Clearance Indoor Outdoor from in. mm in. mm Top 30 762 unobstructed Water Conn. side 12* 305 24 610 Pump side 6* 152 24 610 Front Alcove* unobstructed Rear 8 203 24 610 Vent pipe** 6 152 - - - Hot water pipes per code per code * Water connection and pump side clearances of 24" (610mm) and front clearances of 48" (1219mm) will allow easier service access. ** Using type B vent (refer to Manufacturer's Instructions). Table 1. Minimum boiler clearances from adjacent surfaces. Figure 2. Typical Boiler Installation on Concrete Slab. Figure 3. Typical Boiler Installation on Roof Using Raised Platform (wood). improperly ventilated equipment room can get excessively hot and cause accelerated deterioration of controls and electrical components. In Canada, Table 2 does not apply. Consult local building codes or, in the absence of such requirements, follow CSA-B149.1 standard.