Pepperl+Fuchs FieldConnex Segment Coupler 3 Manuals

1 pdf manual(s) Pepperl+Fuchs FieldConnex Segment Coupler 3 for free download (Document Types: Manual )

Pepperl+Fuchs FieldConnex Segment Coupler 3 Manual  Main Page Preview

Manual  [PDF] (65 pages)

  • Updated: 12.08.2026

Document Preview & Text Transcription

® PROFIBUS Power Hub Segment Coupler 3 (SK3) With HD2-GTR-4PA Gateway PROCESS AUTOMATION MANUAL With regard to the supply of products, the current issue of the following document is ap- plicable: The General Terms of Delivery for Products and Services of the Electrical Indus- try, published by the Central Association of the Electrical Industry (Zentralverband Elektrotechnik und Elektroindustrie (ZVEI) e.V.) in its most recent version as well as the supplementary clause: "Expanded reservation of proprietorship" PROFIBUS Power Hub Segment Coupler 3 (SK3) PROFIBUS Power Hub Segment Coupler 3 (SK3) 3 1 Introduction................................................................................. 5 1.1 Contents................................................................................................ 5 1.2 Target Group, Personnel...................................................................... 5 1.3 Symbols Used ...................................................................................... 5 2 Product Specifications............................................................... 7 2.1 Overview and Application ................................................................... 7 2.2 Coupling................................................................................................ 8 2.3 Segment Supply................................................................................... 9 2.4 System Components ........................................................................... 9 2.5 Recommended System Combinations............................................. 11 2.6 Component Overview ........................................................................ 14 2.7 Technical Data .................................................................................... 15 2.8 Dimensions......................................................................................... 18 3 Installation and Commissioning ............................................. 19 3.1 Mounting and Dismounting............................................................... 19 3.2 Shielding/Grounding ......................................................................... 21 3.2.1 Connection to Equipotential Bonding System .................................. 21 3.3 Connections ....................................................................................... 23 4 Hazardous Area Installation and Use ..................................... 25 4.1 Installation in Zone 2, Category 3G.................................................. 25 5 PROFIBUS Commissioning ..................................................... 26 5.1 Device Address Assignment............................................................. 26 5.2 Cyclic Data Exchange........................................................................ 26 5.2.1 Information on GSD File Conversion................................................ 27 5.2.2 GSD Converter ................................................................................ 28 5.2.3 Information on Watchdog Time (TWD)............................................. 29 5.2.4 Retry Limits...................................................................................... 31 5.2.5 Device Type Manager (DTM): Installation and Commissioning ........ 31 4 PROFIBUS Power Hub Segment Coupler 3 (SK3) 6 Operation................................................................................... 35 6.1 Built-In Slave (BIS) Description ........................................................35 6.2 Coupled Slaves...................................................................................37 6.3 Acyclic Data Exchange with Built-In Slave via Device Type Manager 37 6.3.1 Brief Introduction to DTM with PACTwareTM (Example)...................38 6.3.2 Overview of the Device Type Manager User Interface......................39 6.3.3 HD2-GTR-4PA Structure Diagrams ..................................................39 6.3.4 Watchdog Time in the Device Type Manager ...................................40 6.3.5 PROFIBUS PA Retry Limit in the Device Type Manager...................41 6.3.6 Restart Functions, Redundancy Switchover, and Firmware Update .41 6.4 Redundant Operation.........................................................................44 7 Advanced Diagnostics with the PROFIBUS Power Hub ....... 46 7.1 Advanced Diagnostics Infrastructure ..............................................46 7.2 PROFIBUS Advanced Diagnostics Integration................................49 8 Basic Redundancy Concepts .................................................. 51 9 Glossary .................................................................................... 54 10 Parameter Reference List ........................................................ 56 10.1 General Parameters ............................................................................56 10.2 Diagnostic Parameters.......................................................................56 11 Troubleshooting........................................................................ 59 11.1 Faults Indicated via LEDs ..................................................................59 11.2 Fault Indicated via DTM......................................................................60 11.3 Fault Indicated via DCS......................................................................61 11.4 Problems with Gateway Operation....................................................62