Philio PAT14 Quick start manual [PDF] (7 pages)
- Brand: Philio
- Model: PAT14
- Format: PDF
- Updated: 07.09.2026
-
Z-Wave Ultra low temperature sensor
1
-
Cause of Failure
2
-
Group 2, End Point 1 will report ( channel 1)
4
-
Bit3: Set temperature unit.
5
-
CH2 underheat notification
6
-
FCC Interference Statement
7
Document Preview & Text Transcription
Z-Wave Ultra low temperature sensor
PAT14
The Z-Wave Ultra low temperature sensor PAT14 has 2 channel
thermocouple , based on Z-WaveTM technology.
This device is a security enabled Z-Wave Plus™ product. The
encrypted Z-Wave Plus™ messages support PAT14 to communicate
with other Z-Wave Plus™ products.
PAT14 can be used with Z-Wave™ devices (with Z-Wave™ logo) from
different manufacturers, it can also be included in the Z-Wave™
networks from different manufacturers.
All mains operated nodes (even from different manufacturers) in the
network act as repeaters to increase the stability and reliability of the Z-
Wave™ network.
The product is supported with Over-the-Air (OTA) feature for firmware
upgrade.
Specification
Rated
DC5-24V 6mA
RF distance
Min. 40M indoor,
100M outdoor line of sight,
RF Frequency
868.40 MHz, 869.85 MHz(EU)
908.40 MHz, 916.00 MHz(US)
920.9MHz, 921.7MHz,
923.1MHz(TW/SG/Thai/KR)
RF Maximum Power
+10dBm (Peak), -10dBm
(Average)
Dimension
47.5 x 39 x16 mm
Location
Indoor use only
Operation temperature
-10°C - 40°C
Storage Temperature
-20°C - 60°C
Humidity
Up to 85% max
Temperature Detect Range
-250 to 300°C
Sensor type
External K/J/T type
thermocouple
(depend on the user choice)
FCC ID
RHHPAT14
�
Specifications are subject to change and improvement without
notice.
1
Pages Preview: