Philips Wisp Manuals
3 pdf manual(s) Philips Wisp for free download (Document Types: Caregiver manual, Instructions for use, Manual )
Philips Wisp Caregiver manual [PDF] (12 pages)
- Identifier: id-1170090
- Brand: Philips
- Device: Wisp Personal Care Products
- Type: PDF
- Key Aspects: Error Code Explanations, End-of-Life Handling and Disposal, Control Panel and Interface Navigation
- UPD Date: 19.07.2026
- Source File: 988269.pdf
- Pages: 12
- Description: Professional user manual for the Philips Wisp.
Click to expand and read text
Pediatric nasal mask Wisp Caregiver guide
Philips Wisp Instructions for use [PDF] (2 pages)
- Identifier: id-2308343
- Brand: Philips
- Device: Wisp Medical Equipment
- Type: PDF
- Key Aspects: Additional Modules and Accessories Guide, Pre-Deployment Preparation Steps, Information on Regular Maintenance
- UPD Date: 10.06.2026
- Source File: 1979281.pdf
- Pages: 2
- Description: Technical instruction manual for the Philips Wisp.
Click to expand and read text
Instructions for Use Wisp Nasal Mask 1098148 R04 JAW 07/25/2013 Respironics Inc. 1001 Murry Ridge Lane Murrysville, PA 15668 USA Intended Use The Wisp Nasal Mask is intended to provide an interface for application of CPAP or bi-level therapy to patients. The mask is for single patient use in the home or multi-patient use in the hospital/ institutional environment. The mask is to be used on patients (>66lbs/30kg) for whom CPAP or bi-level therapy has been prescribed. Notes: • An exhalation port is built into this mask so a separate exhalation port is not required. • This mask does not contain natural rubber latex or DEHP. Caution: U.S. Federal law restricts this device to sale by or on the order of a physician. Symbols Warning or Caution Note Tip Does Not Contain Natural Rubber Latex X1 System One Resistance Control Warnings • This mask is not suitable for providing life support ventilation. • Hand wash prior to use. Inspect the mask for damage or wear (cracking, crazing, tears, etc). Discard and replace any components as necessary. • Some users may experience skin redness, irritation, or discomfort. If this happens, discontinue use and contact your healthcare professional. • Consult a physician or dentist if you encounter tooth, gum, or jaw soreness. Use of a mask may aggravate an existing dental condition. • Consult a physician if you experience the following symptoms while using the mask or after removing it: Drying of the eyes, eye pain, eye infections, or blurred vision. Consult an ophthalmologist if symptoms persist. • The mask material should be away from your eyes. • Do not block or seal off the exhalation ports. • Do not overtighten the headgear straps. Watch for signs of overtightening, such as excessive redness, sores, or bulging skin around the edges of the mask. Loosen the headgear straps to alleviate symptoms. • This mask is designed for use with CPAP or bi-level systems recommended by your health care professional or respiratory therapist. Do not wear this mask unless the CPAP or bi-level system is turned on and operating properly. Do not block or try to seal the exhalation port. Explanation of the Warning: CPAP systems are intended to be used with special masks with connectors which have vent holes to allow continuous flow of air out of the mask. When the CPAP machine is turned on and functioning properly, new air from the CPAP machine flushes the exhaled air out through the attached mask exhalation port. However, when the CPAP machine is not operating, enough fresh air will not be provided through the mask, and exhaled air may be rebreathed. Rebreathing of exhaled air for longer than several minutes can in some circumstances lead to suffocation. This warning applies to most models of CPAP systems. • If oxygen is used with the device, the oxygen flow must be turned off when the device is not operating. Explanation of the Warning: When the device is not in operation, and the oxygen flow is left on, oxygen delivered into the ventilator tubing may accumulate within the device enclosure. Oxygen accumulated in the device enclosure will create a risk of fire. • At a fixed flow rate of supplemental oxygen flow, the inhaled oxygen concentration will vary, depending on the pressure settings, patient breathing pattern, mask selection, and the leak rate. This warning applies to most types of CPAP and bi-level machines. • At low CPAP or EPAP pressures the flow through the exhalation port may be inadequate to clear all exhaled gas from the tubing. Some rebreathing may occur. • Attaching an exhalation device requires therapy pressure level adjustment to compensate for increased leak. Specifications Warning: The technical specifications of the mask are provided for your healthcare professional to determine if it is compatible with your CPAP or bi-level therapy device. If used outside these specifications, or if used with incompatible devices, the mask may be uncomfortable, the seal of the mask may not be effective, optimum therapy may not be achieved, and leak, or variation in the rate of leak, may affect device function. Pressure Flow Curve 0 10 20 30 40 50 60 0 5 10 15 20 25 30 Flow Rate (SLPM) Pressure cm H2O Resistance Drop in Pressure at 50 SLPM 100 SLPM All sizes 0.8 cm H2O 3.2 cm H2O Deadspace Volume P 37 mL S/M 49 mL L 73 mL XL 85 mL Sound Levels A-weighted Sound Power Level 27 dBA A-weighted Sound Pressure Level at 1 m 19 dBA Disposal Dispose of in accordance with local regulations. Storage Conditions Temperature: -4º to 140º F (-20º to +60º C) Relative Humidity: 15% to 95% non-condensing Limited Warranty Respironics, Inc. warrants that its mask systems (including mask frame and cushion) (the “Product”) shall be free from defects of workmanship and materials for a period of ninety (90) days from the date of purchase (the “Warranty Period”). If the Product fails under normal conditions of use during the Warranty Period and the Product is returned to Respironics within the Warranty Period, Respironics will replace the Product. This warranty is non-transferable and only applies to the original owner of the Product. The foregoing replacement remedy will be the sole remedy for breach of the foregoing warranty. This warranty does not cover damage caused by accident, misuse, abuse, negligence, alteration, failure to use or maintain the Product under conditions of normal use and in accordance with the terms of the product literature, and other defects not related to materials or workmanship. This warranty does not apply to any Product that may have been repaired or altered by anyone other than Respironics. Respironics disclaims all liability for economic loss, loss of profits, overhead, or indirect, consequential, special or incidental damages which may be claimed to arise from any sale or use of the Product. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. THIS WARRANTY IS GIVEN IN LIEU OF ALL OTHER EXPRESS WARRANTIES. IN ADDITION, ANY IMPLIED WARRANTY, INCLUDING ANY WARRANTY OF MERCHANTABILITY OR FITNESS FOR A PARTICULAR PURPOSE, IS SPECIFICALLY DISCLAIMED. SOME STATES DO NOT ALLOW DISCLAIMERS OF IMPLIED WARRANTIES, SO THE ABOVE LIMITATION MAY NOT APPLY TO YOU. THIS WARRANTY GIVES YOU SPECIFIC LEGAL RIGHTS, AND YOU MAY ALSO HAVE OTHER RIGHTS, WHICH VARY FROM STATE TO STATE. To exercise your rights under this limited warranty, contact your local authorized Respironics, Inc. dealer or Respironics, Inc. at 1001 Murry Ridge Lane, Murrysville, Pennsylvania 15668, 1-800-345-6443 (USA and Canada only) or 1-724-387-4000.
Philips Wisp Manual [PDF] (24 pages)
- Identifier: id-2062003
- Brand: Philips
- Device: Wisp Medical Equipment
- Type: PDF
- Key Aspects: Step-by-Step Assembly Procedures, Environmental Factors and Restrictions, Regulatory Compliance and Standards
- UPD Date: 04.07.2026
- Source File: 2225854.pdf
- Pages: 24
- Description: Practical operating guide for the Philips Wisp.
Click to expand and read text
Wisp Nasal Mask Wisp Youth Nasal Mask |
Wisp: Related Instructions
Quick start guide for the Philips HQ9190CC Electric Shaver. This documentation provides step-by-step guidance on performance optimization, firmware updates, usage examples.
Need help? Call us! Philips representatives are ready to help you with any questions about your new product. CALL US BEFORE YOU CONSIDER RETURNING THE PRODUCT! Official operating instructions for the Philips AZ2538 CD Player. It contains information on compatibility information, support details, troubleshooting tips, connectivity setup.
HTL4110B Register your product and get support at www.philips.com/welcome Always there to help you Question? Contact Philips Quick start guide HTL4110B_93_QSG_V User and installation guide for the Philips HTL4110B Speaker System. This manual outlines installation support, operational procedures, service instructions, startup procedures.
Technical operation manual for the Philips FWD792/98 Stereo System. This manual provides guidance on software configuration, operating instructions, device instructions.
Chicago Accessories WIRE GUARDS, MOUNTING SHELVES, AND REMOTE LAMPS Page 1 of 2 Job Information Type: Job Name: Cat. No.: Notes: 15.0" (38.1 cm) W MJPG1 MJPG2 M User guide for the Philips Chicago Accessories MJ Series Light Fixture. This manual provides guidance on technical troubleshooting, troubleshooting guides, reset instructions.
FlexCare Rechargeable Sonic Toothbrush FlexCare 充電式音波震動牙刷 FlexCare 充电式 声波震动 牙刷 請登錄以下網址可得到相對應協助 Practical user guide for the Philips HX6962/70 Electric Toothbrush. The manual details component overview, firmware installation, firmware updates, system configuration.
Similar Manuals in the Medical Equipment, Personal Care Products Category
Dash Responder Version V 1.0 Servicing Instructions 2004768-001 ENG Revision F Full technical guide for the GE Dash Responder Medical Equipment. This reference includes maintenance guidelines, operating conditions, component overview, diagnostic information.
FA-2020-064 Baxter is a registered trademark of Baxter International, Inc. Page 1 of 2 Urgent Field Safety Notice PrisMax, V2, ROW FA-2020-064 Safety Alert Janu User documentation for the baxter PrisMax V2 Medical Equipment. The manual outlines technical specifications and hardware instructions, operating modes, safety protocols.
- 1 - IMPORTANT! Remove this guide before giving the device to the patient. Only medical professionals should adjust pressure settings. This guide provides you Operating and setup manual for the Philips BiPAP Pro Bi-Flex Medical Equipment. This manual covers reset instructions, setup guidelines, error codes.
COOL CURE 365/365HP/390/395/405 UV LED SYSTEM TECHNICAL REFERENCE MANUAL AUV/LESCO A Division of American Ultraviolet Company WWW.LESCOUV.COM 23555 Telo Ave Product documentation for the Lesco Cool Cure 365 Medical Equipment. The document explains firmware installation, operating conditions, technical guidelines.