PIE 520 Manuals

1 pdf manual(s) PIE 520 for free download (Document Types: Operating instructions)

Available Documents for 520:

PIE 520 Operating instructions Main Page Preview

Operating instructions [PDF] (3 pages)

  • Brand: PIE
  • Model: 520
  • Format: PDF
  • Key Aspects: Critical Operational Precautions, Cleaning and Sanitization Methods, System Limitations and Considerations
  • Updated: 29.03.2026
  • Source File: 1986872.pdf
  • Pages: 3
  • Description: Service and user manual for the PIE 520.

Document Preview & Text Transcription

Practical Instrument Electronics Model 520/521 TC Simulator(s) Operating Instructions Basic Keypad Operations 1 EZ-Check™ Switch Slide the switch to select from three user stored values for the desired calibration points. The User can select HI, DIAL and LO positions. These values can easily be changed to suit the calibration requirements. . 2 ON/OFF Switch Slide the ON/OFF Switch to turn the Model 520/521 on or off. 3 EZ-Dial™ Knob The EZ-Dial™ Knob has two adjustment speeds. Simply turning the EZ-Dial™ Knob will select fine adjustments. While pressing down and turning the EZ-Dial™ Knob will make course adjustments. Note: When the EZ-Check™ Switch is in the HI or LO position, pressing and holding the EZ- Dial™ Knob without turning will store new HI or LO values. Model 520/521 Configuration Instructions for Enabling and Disabling the Configuration Options 1. Turn the Model 520/521 on with the ON/OFF Switch2. 2. Press the EZ-Dial Knob3 while the “PRESS EZ-DIAL KNOB FOR CONFIGURATION” message is displayed. 3. Select options by turning the EZ-Dial Knob until the arrow points to the desired option. 4. The option can be enabled or disabled by tapping the EZ-Dial Knob. The Model 520/521 configuration menu will exit automatically after 5 seconds of inactivity and go to normal operation with the options selected. These options are recalled at turn on until they are changed again. 841 Holt Road #1 • Webster, NY 14580 Tel: 585-872-9350 • Fax: 585-872-2638 [email protected] • http://www.piecal.com/ Practical Instrument Electronics, Inc. Copyright  2003. All rights reserved. 520/521-9002 2/27/03 1-3 Model 520/521 Operating Instructions Model 520/521 Configuration Model 520/521 Configuration Menu Auto Off ON (default)/OFF If Auto Off is ON, the unit will turn off after 30 minutes to save battery life, if there is no user activity. If Auto Off is OFF the unit will stay on until it is turned off from the keypad. This is typically useful for manual loading or continuous use. Display Units °C (default)/°F Pressing the EZ-Dial Knob to toggles between °C or °F TC {tc type} Model 520: The T/C type is fixed as ordered from the factory and cannot be changed. {tc type} is one of: B, E, J, K, N, R, S, T, or mV Model 521: To change T/C type, press the EZ-Dial Knob. Turn the EZ-Dial Knob to scroll through the list of available types. Press again to save and return to the configuration menu. {tc type} is any of: B, E, J, K, N, R, S, T, or mV EZ-Dial™ Knob Turning the EZ-Dial Knob to adjust the output up or down. Fine adjustments can be made by turning the EZ-Dial Knob. Coarse adjustments can be made by pressing and turning the EZ-Dial™. New values can be stored into the HI and LO EZ-Check™ positions by pressing down on the EZ-Dial Knob until “STORED” is indicated on the display. EZ-Check™ Switch The EZ-Check™ Switch has three positions: HI, DIAL, and LO. Its position is shown at the left edge of the display with “HI” and “LO” indicators. The output is adjustable in all three positions. The EZ-Check™ Switch allows user-selected values to be stored in the HI and LO positions when used in combination with the EZ-Dial Knob. To store new EZ-Check™ value(s): 1. Dial the display to match the desired stored outputs for the HI or LO positions. 2. Press down on the EZ-Dial Knob until the confirmation message “STORED” appears. 3. Recall the values by moving the switch between HI, DIAL, and LO. Operational description: When returning to previously set EZ-Check™ positions, the DIAL position always recalls the last output value it was dialed to. The HI and LO positions will recall the last STORED value, NOT the last output value it was last dialed to. Hint: For faster calibrations, the product has been designed so the position of the switch can be felt. This tactile feature allows continuous monitoring of the device being calibrated without looking back at the Model 520/521 display. This is also useful in poor lighting or under difficult operating conditions. 841 Holt Road #1 • Webster, NY 14580 Tel: 585-872-9350 • Fax: 585-872-2638 [email protected] • http://www.piecal.com/ Practical Instrument Electronics, Inc. Copyright  2003. All rights reserved. 520/521-9002 2/27/03 2-3 Model 520/521 Operating Instructions 841 Holt Road #1 • Webster, NY 14580 Tel: 585-872-9350 • Fax: 585-872-2638 [email protected] • http://www.piecal.com/ Practical Instrument Electronics, Inc. Copyright  2003. All rights reserved. 520/521-9002 2/27/03 3-3 Connection Diagram Two Wire Connection to Transmitter WARRANTY Our equipment comes with a NIST traceable Certificate and is guaranteed against defective material and workmanship (excluding batteries) for a period of three years from the date of shipment. Claims under guarantee can be made by returning the equipment prepaid to our factory. The equipment will be repaired, replaced or adjusted at our option. The liability of Practical Instrument Electronics (PIE) is restricted to that given under our guarantee. No responsibility is accepted for damage, loss or other expense incurred through sale or use of our equipment. Under no condition shall Practical Instrument Electronics, Inc. be liable for any special, incidental or consequential damage.

520: Related Instructions

Manuals from Other Manufacturers