Operating instructions manual [PDF] (16 pages)
- Updated: 13.04.2026
Document Preview & Text Transcription
- 1 -
Safety Regulations
• The unit may only be installed and
operated by personnel who are familiar
with both these instructions and the
current regulations for safety at work
and accident prevention. Follow VDE
and local regulations especially as
regards preventative measures.
• Transport, storage and operating
conditions should all conform to EN
60068-2-6.
• Any guarantee is void following opening
of the housing or unauthorised
modifications.
• The unit should be panel mounted,
otherwise dampness or dust could lead
to function impairment.
• Adequate protection must be provided
on all output contacts especially with
capacitive and inductive loads.
Sicherheitsbestimmungen
• Das Gerät darf nur von Personen
installiert und in Betrieb genommen
werden, die mit dieser Betriebsanleitung
und den geltenden Vorschriften über
Arbeitssicherheit und Unfallverhütung
vertraut sind. Beachten Sie die VDE-
sowie die örtlichen Vorschriften,
insbesondere hinsichtlich Schutz-
maßnahmen.
• Beim Transport, der Lagerung und im
Betrieb die Bedingungen nach EN 60068-
2-6 einhalten (s. technische Daten).
• Durch Öffnen des Gehäuses oder eigen-
mächtige Umbauten erlischt jegliche Ge-
währleistung.
• Montieren Sie das Gerät in einen
Schaltschrank; Staub und Feuchtigkeit
können sonst zu Beeinträchtigungen der
Funktionen führen.
• Sorgen Sie an allen Ausgangskontakten
bei kapazitiven und induktiven Lasten für
eine ausreichende Schutzbeschaltung.
Conseils préliminaires
• La mise en oeuvre de l’appareil doit être
effectuée par une personne spécialisée
en installations électriques, en tenant
compte des prescriptions des différentes
normes applicables (NF, EN, VDE...)
notamment au niveau des risques
encourus en cas de défaillance de
l’équipement électrique.
• Respecter les exigences de la norme
EN 60068-2-6 lors du transport, du
stockage et de l'utilisation de l'appareil.
• L’ouverture de l’appareil ou sa modifi-
cation annule automatiquement la
garantie.
• L’appareil doit être monté dans une ar-
moire; l’humidité et la poussière pouvant
entraîner des aléas de fonctionnement.
• Vérifiez que le pouvoir de coupure des
contacts de sortie est suffisant en cas
de circuits capacitifs ou inductifs.
Bestimmungsgemäße Verwendung
Das Sicherheitsschaltgerät dient dem
sicherheitsgerichteten Unterbrechen eines
Sicherheitsstromkreises.
Das Sicherheitsschaltgerät erfüllt Forderun-
gen der EN 60947-5-1, EN 60204-1 und
VDE 0113-1 und darf eingesetzt werden in
Anwendungen mit
• Not-Halt-Tastern
• Schutztüren
Domaines d’utilisation
Le bloc logique de sécurité sert à
interrompre en toute sécurité un circuit de
sécurité.
Le bloc logique de sécurité satisfait aux
exigences des normes EN 60947-5-1,
EN 60204-1 et VDE 0113-1 et peut être
utilisé dans des applications avec des
• poussoirs d’arrêt d’urgence
• protecteurs mobiles
Authorised Applications
The safety relay provides a safety-related
interruption of a safety circuit.
The safety relay meets the requirements of
EN 60947-5-1, EN 60204-1 and VDE 0113-
1 and may be used in applications with
• E-STOP pushbuttons
• Safety gates
Description
The Safety Relay PNOZ X2C/X2.1C is
enclosed in a PL-99 housing. The version
available is for 24 V AC or DC operation
only.
Features:
• Relay outputs: 2 safety contacts (N/O),
positive-guided.
• Connections for Emergency Stop Button,
Safety Gate Limit Switch and Reset
button.
• PNOZ X2C: monitored manual reset
• PNOZ X2.1C: automatic reset possible
• Status Indicators.
• Feedback Control Loop for monitoring of
external contactors/relays possible.
• no galvanic seperation
The relay complies with the following safety
requirements:
• The circuit is redundant with built-in self-
monitoring
• The safety function remains effective in
the case of a component failure.
• The correct opening and closing of the
safety function relays is tested
automatically in each on-off cycle.
Description de l’appareil
Inséré dans un boîtier PL 99, le bloc
logique de sécurité PNOZ X2C/X2.1C est
alimenté en 24 V AC ou DC.
Particularités :
• Sorties disponibles : 2 contacts à
fermeture de sécurité
• Bornes de raccordement pour poussoirs
AU, détecteurs de position et poussoir de
validation
• PNOZ X2C: surveillance du circuit de
validation
• PNOZ X2.1C: réarmement automatique
possible
• LEDs de visualisation
• Auto-contrôle des contacteurs externes
possible
• pas d'isolation galvanique
Le relais PNOZ X2C/X2.1C répond aux
exigences suivantes :
• conception redondante avec auto-
surveillance
• sécurité garantie même en cas de
défaillance d’un composant
• test cyclique (ouverture/fermeture des
relais internes) à chaque cycle Marche/
Arrêt de la machine
19918-6NL-03
PNOZ X2C, PNOZ X2.1C
� �
�����������������
� ��
����������������������
� �
��������������������
Gerätebeschreibung
Das Sicherheitsschaltgerät PNOZ X2C/
X2.1C ist in einem PL-99-Gehäuse unterge-
bracht. Die Versorgungsspannung beträgt
24 V AC oder DC.
Merkmale:
• Relaisausgänge: 2 Sicherheitskontakte
(Schließer), zwangsgeführt
• Anschlussmöglichkeit für Not-Halt-
Taster, Schutztürgrenztaster und
Starttaster
• PNOZ X2C: überwachter Starttaster
• PNOZ X2.1C: automatischer Start
möglich
• Statusanzeige
• Überwachung externer Schütze möglich
• keine galvanische Trennung
Das Schaltgerät erfüllt folgende Sicherheits-
anforderungen:
• Schaltung ist redundant mit Selbst-
überwachung aufgebaut
• Sicherheitseinrichtung bleibt auch bei
Ausfall eines Bauteils wirksam.
• Bei jedem Ein-Aus-Zyklus der Maschine
wird automatisch überprüft, ob die Relais
der Sicherheitseinrichtung richtig öffnen
und schließen.
� �
��������������������
� �
��������������������
� ��
������������������
- 2 -
Funktionsbeschreibung
Das Schaltgerät PNOZ X2C/X2.1C dient
dem sicherheitsgerichteten Unterbrechen
eines Sicherheitsstromkreises. Nach
Anlegen der Versorgungsspannung leuchtet
die LED "POWER". Das Gerät ist betriebs-
bereit, wenn der Startkreis S33-S34
geschlossen ist.
• Eingangskreis geschlossen (z. B. Not-
Halt-Taster nicht betätigt):
Relais K1 und K2 gehen in Wirkstellung
und halten sich selbst. Die Statusan-
zeigen für "CH.1" und "CH.2" leuchten.
Die Sicherheitskontakte 13-14/23-24 sind
geschlossen.
• Eingangskreis wird geöffnet (z. B. Not-
Halt-Taster betätigt):
Relais K1 und K2 fallen in die Ruhe-
stellung zurück. Die Statusanzeige für
"CH.1" und "CH.2" erlischt. Die Sicher-
heitskontakte 13-14/23-24 werden
redundant geöffnet.
Description du fonctionnement
Le relais PNOZ X2C/X2.1C assure de façon
sure, l’ouverture d’un circuit de sécurité. A
la mise sous tension du relais (A1-A2), la
LED "POWER" s'allume. Le relais est activé
si le circuit de réarmement S33-S34 est
fermé.
• Circuits d'entrée fermés (poussoir AU non
actionné) :
Les relais K1 et K2 passent en position
travail et s'auto-maintiennent. Les LEDs
"CH.1" et CH.2" s'allument. Les contacts
de sécurité (13-14/23-24) sont fermés.
• Circuits d'entrée ouverts (poussoir AU
actionné) :
Les relais K1 et K2 retombent. Les LEDs
"CH.1" et "CH.2" s'éteingnent. Les
contacts de sécurité (13-14/23) s'ouvrent.
Function Description
The relay PNOZ X2C/X2.1C provides a
safety-oriented interruption of a safety
circuit. When the operating voltage is
supplied the LED "POWER" is illuminated.
The unit is ready for operation, when the
reset circuit S33-S34 is closed.
• Input Circuit closed (e.g. the Emergency
Stop button is not pressed):
Relays K1and K2 energise and retain
themselves. The status indicators for
"CH.1" and "CH.2" illuminate. The safety
contacts (13-14/23-24) are closed.
• Input Circuit is opened (e.g. Emergency
Stop is pressed):
Relays K1 and K2 de-energise. The
status indicators for "CH.1" and "CH.2" go
out. The safety contacts (13-14/23-24)
will be opened (redundant).
A1 (L+)
A2 (L-)
S22
S12
S21
S33 S11
13
14
K1
K2
23
24
S34
Start
Unit
Start
Unit
Fig. 1: Innenschaltbild/Internal Wiring
Diagram/Schéma de principe
Betriebsarten:
• Einkanaliger Betrieb:
Eingangsbeschaltung nach VDE 0113
Teil 1 und EN 60204-1; keine Redundanz
im Eingangskreis; Erdschlüsse im
Startkreis werden erkannt. Bei
Erdschlüssen im Not-Halt-Kreis löst die
Sicherung der Versorgungsspannung aus.
• Zweikanaliger Betrieb: Redundanter Ein-
gangskreis, Erdschlüsse im Tasterkreis
und Querschlüsse zwischen den Taster-
kontakten werden erkannt.
• Nur PNOZ X2.1C: automatischer Start:
Gerät ist aktiv, sobald Eingangskreis
geschlossen ist.
• Manueller Start: Gerät ist erst dann aktiv,
wenn ein Starttaster betätigt oder ein
Startkontakt geschlossen wird.
• Nur PNOZ X2C: Überwachter Start:
Gerät ist nur aktiv, wenn vor dem
Schließen des Eingangskreises der
Startkreis geöffnet wird und der Start-
kreis nach dem Schließen des Eingangs-
kreises und nach Ablauf der Wartezeit
(s. techn. Daten) geschlossen wird.
Dadurch ist eine automatische Aktivie-
rung durch Überbrückung des Start-
tasters ausgeschlosssen.
• Kontaktvervielfachung und -verstärkung
durch Anschluss von externen Schützen
Operating Modes
• Single-channel operation: Input wiring
according to VDE 0113 part 1 and
EN 60204-1, no redundancy in the input
circuit. Earth faults are detected in the
reset circuit. Earth faults in the
Emergency Stop circuit trigger the internal
electronic fuse.
• Two-channel operation: Redundancy in
the input circuit. Earth faults in the
Emergency Stop circuit and shorts across
the emergency stop push button are also
detected.
• Only PNOZ X2.1C: Automatic reset: Unit
is active as soon as the input circuit is
closed.
• Manual reset: Unit is only active when a
reset button has been pressed or reset
contact is closed.
• Only PNOZ X2C: Monitored manual
reset: Unit will only be active if the reset
circuit is opened before the input circuit
closes, and the reset circuit is closed
after the input circuit has closed and the
waiting time has elapsed (see technical
data). This eliminates the possibility of
the reset button being overridden,
triggering automatic activation.
• Increase in the number of available
contacts by connection of external
contactors/relays.
Modes de fonctionnement
• Commande par 1 canal : conforme aux
prescriptions de la EN 60204/1, pas de
redondance dans le circuit d’entrée. La
mise à la terre du circuit de réarmement
est détectée. En cas de mise à la terre
des circuits d'entrée, le fusible
électronique déclenche.
• Commande par 2 canaux : circuit d’entrée
redondant. La mise à la terre et les
courts-circuits entre les contacts sont
détectées.
• PNOZ X2.1C uniquement : réarmement
automatique : le relais est activé dès la
fermeture des canaux d’entrée.
• Réarmement manuel : le relais n’est
activé qu’après une impulsion sur un
poussoir de validation.
• PNOZ X2C uniquement : Réarmement
manuel auto-contrôlé : L'appareil est
uniquement actif lorsque le circuit de
réarmement est ouvert avant fermeture
des circuits d'entrées et que le circuit de
réarmement est fermé après fermeture
des circuits d'entrées et écoulement du
temps d'attente (voir les caractéristiques
techniques). Cette mesure permet
d'éviter toute activation automatique et
toute inhibition du poussoir de
réarmement.
• Augmentation du nombre de contacts ou
du pouvoir de coupure par l’utilisation de
contacteurs externes.
- 3 -
Montage
Das Sicherheitsschaltgerät muss in einen
Schaltschrank mit einer Schutzart von
mind. IP54 eingebaut werden. Zur Be-
festigung auf einer Normschiene dient ein
Rastelement auf der Rückseite des
Geräts. Sichern Sie das Gerät bei Montage
auf einer senkrechten Tragschiene
(35 mm) durch ein Halteelement wie z. B.
Endhalter oder Endwinkel.
Inbetriebnahme
Beachten Sie bei der Inbetriebnahme:
• Vor die Ausgangskontakte eine
Sicherung (10 A flink oder 6 A träge)
schalten, um das Verschweißen der
Kontakte zu verhindern.
• Berechnung der max. Leitungslänge Imax
im Eingangskreis:
�����
�������
������
Rlmax = max. Gesamtleitungs-
widerstand (s. technische Daten)
Rl /km = Leitungswiderstand/km
• Da die Funktion Querschlusserkennung
nicht einfehlersicher ist, wird sie von Pilz
während der Endkontrolle geprüft. Eine
Überprüfung nach der Installation des
Geräts ist wie folgt möglich:
1. Gerät betriebsbereit (Ausgangs-
kontakte geschlossen)
2. Die Testklemmen S12/S22 zur
Querschlussprüfung kurzschließen.
3. Die Sicherung im Gerät muss auslösen
und die Ausgangskontakte öffnen.
Leitungslängen in der Größenordnung
der Maximallänge können das Auslö-
sen der Sicherung um bis zu 2 Minuten
verzögern.
4. Sicherung wieder zurücksetzen: den
Kurzschluss entfernen und die Versor-
gungsspannung für ca. 1 Minute
abschalten.
• Leitungsmaterial aus Kupferdraht mit
einer Temperaturbeständigkeit von
60/75 °C verwenden.
• Sorgen Sie beim Anschluss von magne-
tisch wirkenden, auf Reedkontakten
basierenden Näherungsschaltern dafür,
dass der max. Einschaltspitzenstrom
(am Eingangskreis) den Näherungs-
schalter nicht überlastet.
• Angaben im Kapitel „Technische Daten“
unbedingt einhalten.
Ablauf:
• Versorgungsspannung:
Versorgungsspannung an Klemmen A1
und A2 anlegen.
• Startkreis:
- nur PNOZ X2.1C: Automatischer Start:
S33-S34 brücken.
- Manueller Start (mit Überwachung bei
PNOZ X2C):
Taster an S33-S34 anschließen.
• Eingangskreis:
- Einkanalig:
Öffnerkontakt von Auslöseelement
zwischen Plusklemme (L+) der
Versorgungsspannung und Klemme A1
anschließen, S11-S12 und S21-S22
brücken.
- Zweikanalig: Öffnerkontakt von Auslöse-
element an S11-S12 und S21-S22
anschließen.
• Rückführkreis:
Externe Schütze in Reihe zu Startkreis
S33-S34 anschließen.
Montage
Le relais doit être monté en armoire ayant
un indice de protection mini IP54. Sa face
arrière permet un montage sur rail DIN.
Immobilisez l'appareil monté sur un rail DIN
vertical (35 mm) à l'aide d'un élément de
maintien comme par ex. un support ou une
équerre terminale.
Installation
The safety relay must be panel mounted
(min. IP54). There is a notch on the rear of
the unit for DIN-Rail attachment. If the unit
is installed on a vertical mounting rail (35
mm), ensure it is secured using a fixing
bracket such as end bracket.
Operation
Please note for operation:
• To prevent a welding together of the
contacts, a fuse (10 A quick/6 A slow
acting) must be connected before
the output contacts.
• Calculate the max. Cable runs Imax in the
input circuit:
�����
�������
������
Rlmax = Max. Total cable resistance
(see technical details)
Rl /km = Cable resistance/km
• As the function for detecting shorts across
the inputs is not failsafe, it is tested by
Pilz during the final control check.
However, a test is possible after installing
the unit and it can be carried out as
follows:
1. Unit ready for operation (output
contacts closed)
2. Short circuit the test (connection)
terminals S12/S22 for detecting shorts
across the inputs
3. The unit‘s fuse must be triggered and
the output contacts must open. Cable
lengths in the scale of the maximum
length can delay the fuse triggering for
up to 2 minutes.
4. Reset the fuse: remove the short circuit
and switch off the operating voltage for
approx. 1 minute.
• Use copper wiring that will withstand
60/75 °C
• When connecting magnetically operated,
reed proximity switches, ensure that the
max. peak inrush current (on the input
circuit) does not overload the proximity
switch.
• Important details in the section
"Technical Data“ should be noted and
adhered to.
To operate:
• Supply operating voltage:
Connect the operating voltage to
terminals A1 and A2.
• Reset circuit:
- only PNOZ X2.1C: Automatic reset:
Bridge S33-S34
- Manual reset (PNOZ X2C with
monitoring): Connect button to
S33-S34.
• Input circuit:
- Single-channel: Connect N/C contact
from safety switch between the positive
terminal (L+) of the operating voltage
and terminal A1, link S11-S12 and S21-
S22.
- Two-channel: Connect N/C contact
from safety switch (e.g. Emergency-
Stop) to S11-S12 and S21-S22.
• Feedback control loop:
Connect external contactors/relays in
series with reset circuit S33-S34.
Mise en oeuvre
Remarques préliminaires :
• Protection de contacts de sortie par
des fusibles 10 A rapides ou 6 A
normaux pour éviter leur soudage
• Calcular les longueurs de câblage max
Imax dans le circuit d’entrée:
�����
�������
������
Rlmax = résistivité de câblage totale max.
(voir les caractéristiques techniques)
Rl /km = résistivité de câblage/km
• La fonction de détection de court-circuit
est testé par Pilz lors du contrôle final. Un
test sur site est possible de la façon
suivante :
1. Appareil en fonction (contacts de sortie
fermés)
2. Court-circuiter les bornes de raccorde-
ment nécessaires au test S12/S22
3. Le fusible interne du relais doit
déclencher et les contacts de sortie
doivent s‘ouvrir. Le temps de réponse
du fuisible peut aller jusqu‘à 2 min, si
les longueurs de câblage sont proches
des valeurs maximales.
4. Réarmement du fusible : enlever le
court-circuit et couper l‘alimentation du
relais pendant au moins 1 min.
• Utiliser uniquement des fils de cablâge en
cuivre 60/75 °C.
• Lors du raccordement de détecteurs de
proximité magnétiques, basés sur des
contacts Reed, veuillez vous assurer
que le courant de crête max. à la mise
sous tension (sur le circuit d'entrée) ne
surcharge pas les détecteurs de
proximité.
• Respecter les données indiquées dans
le chap. „Caractéristiques techniques“.
Mise en oeuvre :
• Tension d’alimentation :
amener la tension d’alimentation sur A1
et A2
• Circuit de réarmement :
- PNOZ X2.1C uniquement :
réarmement automatique : pontage des
bornes S33-S34
- Réarmement manuel (auto-contrôlé sur
PNOZ X2C) : câblage d'un poussoir sur
S33-S34
• Circuits d’entrée:
- Commande par 1 canal : câblage du
contact à ouverture entre le potentiel
(L+) de la tension d'alimentation et la
borne A1 (+), pontage entre S11-S12 et
S21-S22
- Commande par 2 canaux : câblage des
contacts à ouverture entre S11-S12 et
S21-S22
• Boucle de retour :
Câblage en série des contacts externes
dans le circuit de rèarmement S33-S34
Pages Preview: