Pittway Fire-Lite Alarms MMF-300 Manuals

1 pdf manual(s) Pittway Fire-Lite Alarms MMF-300 for free download (Document Types: Installation instructions manual)

Document Preview & Text Transcription

@©)Fire ure A,arms MMF-300 Monitor Module Installation Instructions Specifications Normal Operating Voltage: EOL Resistance: Maximum IDC Resistance: Temperature Range: Humidity: Dimensions: Accessories: 15 to 32 voe 47K Ohms 1,500 Ohms 32'F to 120'F (O'C to 49'C) 10% to 93% Noncondensing 4'/," Hx 4" Wx 1/," D (Mounts to a 4" square by 2/%" deep box.) SMB500 Electrical Box Before Installing This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. General Description The MMF-300 Monitor Module is intended for use in addressable, two-wire systems, where the individual address of each module is se- lected using the built-in rotary switches. It provides either a 2-wire or 4-wire fault tolerant Initiating Device Circuit (IDC) for normally open contact fire alarm or supervisory devices. The module has a panel controlled LED indicator. The MMF-300 can be used to replace an M300 module in existing systems. Compatibility Requirements To ensure proper operation, these modules shall be connected to listed compatible system control panels only. Mounting The MMF-300 mounts directly to 4" square electrical boxes (see Figure 2). The box must have a minimum depth of 2'/,". Surface mounted electrical boxes (SMB500) are available. Wiring NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. This module is intended for power limited wiring only. 1. Install module wiring in accordance with the job drawings and appropriate wiring diagrams. 2. Set the address on the module per job drawings. NOTE: Some panels support extended addressing. In order to set the module above address 99 on Fire•Lite compatible systems, carefully remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1. 3. Secure module to electrical box (supplied by installer), as shown in Figure 2. Figure 1. Controls and indicators: 3 0 ~ ~ 0 so ~ 8 3 12 2 13 ] 7 % TENS, 7 g al {® ( 8 ONES LOOP ~ 0 {) ~ 0 A78-2318-07 F300-02-00 Figure 2. Module mounting: I A/8-2610-10 156-1191-01 Fire•Lite Alarms, Inc., One Fire-Lite Place., North ford, CT 064 72, 203-484-7161 Figure 3. Typical 2-wire Initiating Device Circuit {IDC) configuration, NFPA Style B (Class B): TONEXT ~ + ovoovoov DEVICE MONITOR ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME MODULE. Q o p, 47 K EOL RESISTOR ELR-47K MODULE 0 CONNECT MODULES TO LISTED COMPATIBLE NOTIFIER CONTROL PANELS ONLY o ''z FROMPANEL OR r=-----a.. eernous '"'" ~ 0 0 ' couuUNiCATON uNE 32 voe MAX. SHIELDED-TWISTED PAIR IS RECOMMENDED INITIATING DEVICE CIRCUIT (IDC)- NFPA STYLE B POWER LIMITED: 230A MAX @ 12 VDC MAX INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED A78-2280-15 Figure 4. Typical 4-wire fault tolerant Initiating Device Circuit (IDC) configuration, NFPA Style D (Class A): TO NEXT '' DEVICE e J©?< > DX>OD>OX> ANY NUMBER OF UL LISTED CONTACT CLOSURE DEVICES MAY BE USED. DO NOT MIX FIRE ALARM INITIATING, SUPERVISORY, OR SECURITY DEVICES ON THE SAME MODULE. EOL RESISTOR IS INTERNAL AT TERMINALS 8 & 9. (·) <-of ' {ROM PANEL OR Do>oKC7C?'7 /lz PREVIOUS DEVICE CONNECT MODULES TO LISTED COMPATIBLE CONTROL PANELS ONLY COMMUNICATION LINE 32VDC MAX SHIELDED-TWISTED PAIR IS RECOMMENDED INSTALL CONTACT CLOSURE DEVICES PER MANUFACTURER'S INSTALLATION INSTRUCTIONS. ALL WIRING SHOWN IS SUPERVISED AND POWER LIMITED A78-228 1-62 F300-02-00 2 I56-1191-01 ©1999 Fire•Lite Alarms, Inc. (-,\ere-ure At.arms ~ 1ncorporaTeo INSTALLATION INSTRUCTIONS FOR M301 AND M301A MONITOR MODULES GENERAL M301 and M301 A Monitor Modules provide two-wire, Styles A and B initiating circuits for normally open contact fire alarm and supervisory devices. The M301 and M301A are small enough to fit inside a single gang junction box behind the monitored device. The small size and light weight allow them to be installed without rigid mounting (see Figure 1 ). COMPATIBILITY REQUIREMENTS To insure proper operation, these modules must be connected to compatible addressable Fire-Lite control panels only. INSTALLATION CAUTION Do not connect circuit wiring to control unit or modules, or apply power to any portion of the system until after the circuit test has been performed. Note: All wiring must conform to applicable local codes, ordinances and regulations. 1. Install module wiring in accordance with the job drawings and wiring diagram as appropriate (Figure 2). 2. Set the desired address on the module per job drawings. 3. Record the address and loop on the front of the module if desired. COMPATIBLE ONT ROL PANEL (+) }( ]( D (-) f----------1 --}---!----, NOTES: (f) THE INITIATING CIRCUIT IS CURRENT LIMITED TO 230 µ AMP 10VDC NOM. (Q) DETECTION LOOP PROVIDES THE FOLLOWING SERVICES: -FIRE, AUTOMATIC/MANUAL WATERFLOW ALARM SERVICE WITH N.O. CONTACT DEVICES -SPRINKLER SUPERVISION WITH N.O. CONTACT DEVICES ©vo NOT MIX SERVICES @) INITIATING CIRCUIT LINE REQUIREMENTS MAX. LENGTH- 2500° MAX. RESISTANCE - 40 OHMS "' O co - Figure 1 47K EOL INCLUDED A78-2427-572 Figure 2 Typical 2-wire Styles A and B Initiating Circuit Configuration of a M301 or M301A Monitor Module F300-05-00 156-572-02 Firelite 1993 ©)re ure A,arms CRF-300 Relay Control Module Installation Instructions Specifications Normal Operating Voltage: EOL Resistance: Temperature Range: Humidity: Dimensions: Accessories: 15 to 32 VDC Not used 32F to 120'F (O'C to 49'C) 10% to 93% Noncondensing 44," H x 4" W x 1/," D (Mounts to a 4" square by 2%" deep box.) SMB500 Electrical Box; CB500 Barrier Before Installing This information is included as a quick reference installation guide. Refer to the control panel installation manual for detailed system information. If the modules will be installed in an existing operational system, inform the operator and local authority that the system will be temporarily out of service. Disconnect power to the control panel before installing the modules. NOTICE: This manual should be left with the owner/user of this equipment. General Description The CRF-300 Relay Control Module is intended for use in addressable, two-wire systems, where the individual address of each module is selected using the built-in rotary switches. It allows a compatible control panel to switch discrete contacts by code command. The relay contains two isolated sets of Form-C contacts, which operate as a DPDT switch and are rated in accordance with the table in the manual. Circuit connections to the relay contacts are not supervised by the module. The module also has a panel controlled LED indicator. This module can be used to replace an C304 module that has been configured for Form-C operation. Compatibility Requirements To ensure proper operation, these modules shall be connected to listed compatible system control panels only. Mounting The CRF-300 mounts directly to 4" square electrical boxes (see Figure 2A). The box must have a minimum depth of 2'/,". Sur- face mounted electrical boxes (SMBS00) are available. NOTE: All wiring must conform to applicable local codes, ordinances, and regulations. When using control modules in nonpower limited applications, the CB500 Module Barrier must be used to meet UL requirements for the separation of power-limited and nonpower-limited terminals and wiring. The barrier must be inserted into a 4"x4"x2'/a" junction box, and the control module must be placed into the barrier and attached to the junction box (Figure 2A). The power-limited wiring must be placed into the isolated quadrant of the module barrier (Figure 2B). 1. Install module wiring in accordance with the job drawings and appropriate wiring diagrams. 2. Set the address on the module per job drawings. NOTE: Some panels support extended addressing. In order to set the module above address 99 on compatible systems, carefully remove the stop on the upper rotary switch with thumb in the direction shown in Figure 1. 3. Secure module to electrical box (supplied by installer), as shown in Figure 2A. Figure 1. Controls and indicators: O o 0 0 o A78-2318-08 S I Figure 2A. Module mounting with barrier: Figure 2B: ISOLATED QUADRANT A78-2611-11 F 300-04-00 156-1190-01 Fire·Lite Alarms, Inc., One Fire-Lite Place, Northford, CT 06472, 203-484-7161