Pittway SYSTEM SENSOR 2251 Manuals
1 pdf manual(s) Pittway SYSTEM SENSOR 2251 for free download (Document Types: Installation and maintenance instructions)
Pittway SYSTEM SENSOR 2251 Installation and maintenance instructions [PDF] (4 pages)
- Identifier: id-2296147
- Brand: Pittway
- Device: Pittway SYSTEM SENSOR 2251 Kitchen Appliances
- Type: Installation and maintenance instructions, PDF
- Key Aspects: Step-by-Step Setup Guides, Periodic Maintenance Tasks, Device Safety Standards
- UPD Date: 01.06.2026
- Source File: 1991477.pdf
- Pages: 4
- Description: Detailed user guide for the Pittway SYSTEM SENSOR 2251.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
D200-80-00 1 I56-1236-03R 2251 and 2251T Intelligent Photoelectronic Smoke Sensors INSTALLATION AND MAINTENANCE INSTRUCTIONS A Division of Pittway 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 Before Installing This sensor must be installed in compliance with the con- trol panel system installation manual. The installation must meet the requirements of the Authority Having Jurisdiction (AHJ). Sensors offer maximum performance when installed in compliance with the National Fire Protection Association (NFPA); see NFPA 72. General Description Model 2251 is a plug-in type smoke sensor that combines a photoelectronic sensing chamber with addressable-analog communications. The sensor transmits an analog represen- tation of smoke density over a communication line to a control panel. Rotary-decade switches are provided for set- ting the sensor’s address. Two LEDs on the sensor are con- trolled by the panel to indicate sensor status. An output is provided for connection to an optional remote LED annun- ciator (P/N RA400Z). Model 2251T features a fixed tem- perature (135°F) heat detector. The 2251 and 2251T require compatible addressable communications to function properly. Connect these sensors to listed-compatible control panels only. Spacing System Sensor recommends spacing sensors in compliance with NFPA 72. In low air flow applications with smooth ceilings, space sensors 30 feet apart. For specific informa- tion regarding sensor spacing, placement, and special applications, refer to NFPA 72 or the System Sensor Guide For Proper Use of System Smoke Detectors, available at no charge from System Sensor (P/N I56-407-XX). Specifications Operating Voltage Range: 15 to 32 VDC Standby Current: 300µA @ 24 VDC (one communication every 5 sec. with LED blink enabled) Max. Alarm Current (LED on:) 6.5 mA @ 24 VDC Operating Humidity Range: 10% to 93% Relative Humidity, noncondensing Operating Temperature Range: 0° to 49°C (32° to 120°F); 2251 Operating Temperature Range: 0° to 38°C (32° to 100°F); 2251T Heat Sensor: 135°F Fixed Temperature Electronic Thermistor Height: 1.7 inches (43 mm) installed in B210LP Base Diameter: 6.1 inches (155 mm) installed in B210LP Base 4.1 inches (104 mm) installed in B501 Base Weight: 3.6 oz. (102 g) Additional Bases Available: All 200/500 Series bases are compatible. Duct Applications: 2251 and 2251T are listed for use in ducts. See Duct Applications Guide A05-1004-XX for details on pendant mount applications. Note: These products are not listed for use inside duct smoke detectors. Wiring Instructions All wiring must be installed in compliance with the National Electrical Code, applicable local codes, and any special requirements of the Authority Having Jurisdiction. Proper wire gauges should be used. The installation wires should be color-coded to limit wiring mistakes and ease system troubleshooting. Improper connections will prevent a system from responding properly in the event of a fire. Remove power from the communication line before installing sensors. All wiring must conform to applicable local codes, ordi- nances, and regulations. 1. Wire the sensor base (supplied separately) per the wiring diagram, see Figure 1. 2. Set the desired address on the sensor address switches, see Figure 2. 3. Install the sensor into the sensor base. Push the sensor into the base while turning it clockwise to secure it in place. 4. After all sensors have been installed, apply power to the control unit and activate the communication line. 5. Test the sensor(s) as described in the TESTING section of this manual.
Similar Manuals in the Kitchen Appliances Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
JAC Pico Series |
#16B4ZG: Pico Series Kitchen Appliances User instructions |
108 | 1456 | 321 | 12-08-2026 | view all manuals | |
Audiovox APS95BT2 - Car - Code Learning Transmitter |
APS95BT2 - Car - Code Learning Transmitter Programming manual - 66CWFT |
6 | 0.08 Mb | 310 | 72 | 27-07-2026 | view all manuals |
Soehnle Emotion Limited Edition Bi-Colour |
Emotion Limited Edition Bi-Colour (Kitchen Appliances ePDF Guide, #33F1V2) |
96 | 679 | 116 | 16-07-2026 | view all manuals | |
Temperature alert TM-ZP200 |
Temperature alert Kitchen Appliances Operation & user’s manual (File: PDF, 03-05-2026) |
22 | 826 | 166 | 03-05-2026 | view all manuals | |
WAERATOR WA-A01 |
WAERATOR WA-A01 User Guide (Operation & user’s manual), @2438GB |
16 | 696 | 140 | 09-04-2026 | view all manuals | |
Beko BKK 2110 IM |
BKK 2110 IM Operation & user’s manual - ZI64P5 |
16 | 1475 | 281 | 10-08-2026 | view all manuals |