Puls Dimension Q-Series Manuals
4 pdf manual(s) Puls Dimension Q-Series for free download (Document Types: Manual )
Puls Dimension Q-Series Manual [PDF] (24 pages)
- Identifier: id-1372057
- Brand: Puls
- Device: Puls Dimension Q-Series Power Supply
- Type: Manual , PDF
- Key Aspects: Device Specifications Overview, Recommended Spare Parts List, Pre-Installation Safety Requirements
- UPD Date: 25.05.2026
- Source File: 1355698.pdf
- Pages: 24
- Description: User operation guide for the Puls Dimension Q-Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
QS20.481 Q-Series 48V, 10A, SINGLE PHASE INPUT May 2007 / Rev. 1.2 DS-QS20.481-EN All parameters are specified at 48V, 10A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. 1/24 POWER SUPPLY ■ AC 100-240V Wide-range Input ■ Efficiency up to 94.3% ■ Width only 82mm ■ 150% Peak Load Capability ■ Active Power Factor Correction, PFC ■ DC Input from 88 to 375Vdc ■ Short-term Operation from 60Vac to 300Vac ■ Full Power Between -25°C and +60°C ■ Negligibly Low Inrush Current ■ DC-OK Relay Contact ■ Quick-connect Spring-clamp Terminals 1. GENERAL DESCRIPTION 2. SHORT-FORM DATA Output voltage DC 48V Adjustment range 48-55V Output current 10A continuous, 48V 15A for typ. 4s, 48V Output power 480W continuous, 48V 720W for typ. 4s, 48V Output ripple < 100mVpp 20Hz to 20MHz Input voltage AC 100-240V ±15% Mains frequency 50-60Hz ±6% AC Input current 4.56 / 2.48A at 120 / 230Vac Power factor 0.95 / 0.90 at 120 / 230Vac AC Inrush current typ. 9 / 7A peak at 120 / 230Vac DC Input voltage DC 110-300V - -20%/+25% DC Input current 4.7 / 1.7A at 110 / 300Vdc Efficiency 92.8 / 94.3% at 120 / 230Vac Losses 37.2 / 29.0W at 120 / 230Vac Temperature range -25°C to +70°C operational Derating 12W/°C +60 to +70°C Hold-up time typ. 32 / 51ms at 120 / 230Vac The most outstanding features of this Dimension Q- Series power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. With short-term power capability of 150% and built- in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy. A wide range input voltage design and a negligible low input inrush current make installation and usage simple. Diagnostics are easy due to the DC-ok relay, a green DC-ok and a red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation. Many global approvals make this unit suitable for nearly every situation. QS20.241 QS20.481 QS20.244 QS10.241 QS20.361 Less Power QS20-Series Related products only 200-240V Input, no PFC 36V Output 48V Output Dimensions 82x124x127mm WxHxD 3. ORDER NUMBERS 4. MARKINGS QS20.481 48-55V unit Power Supply Accessory ZM1.WALL Wall mount bracket IND. CONT. EQ. 18WM LISTED UL 508 UL 60950-1 GL Marine, pending ZM15.SIDE Side mount bracket YR2.DIODE Decoupling module EMC, LVD Snaptec Australia [email protected]
Puls Dimension Q-Series Manual [PDF] (27 pages)
- Identifier: id-1372058
- Brand: Puls
- Device: Puls Dimension Q-Series Media Converter
- Type: Manual , PDF
- Key Aspects: Hardware Setup Instructions, Regulatory Compliance and Standards, End-of-Life Handling and Disposal
- UPD Date: 05.07.2026
- Source File: 1355697.pdf
- Pages: 27
- Description: Advanced user manual for the Puls Dimension Q-Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
QS10.241-60 Q-Series 24V, 200W, DC/DC CONVERTER DC/DC CONVERTER EN 50155 Railway Compliant Conformal Coated PC-boards Quick-connect Spring-clamp Terminals 77-154Vdc Wide-range Input Width only 60mm Efficiency up to 93.0% Excellent Partial Load Efficiency Minimal Inrush Current Surge Full Power Between -40°C and +70°C DC-OK Relay Contact Reverse Input Polarity Protected 3 Year Warranty 1/27 GENERAL DESCRIPTION The QS10.241-60 DC/DC converter is designed specifically for railway & transportation applications. It is approved according to the EN 50155 standard, which is an international standard covering electronic equipment used on rolling stock for railway applications. The standard covers aspects such as temperature, humidity, shock, vibration, EMI and other parameters. Because of these requirements, the unit is equipped with conformal coated pc-boards. The unit features a DC-OK signal contact for remote monitoring, and quick-connect spring-clamp terminals for a reliable connection even when mechanical vibration and shock are involved. The unit also covers an extreme wide temperature range from -40°C up to +70°C with full output current. This DC/DC converter comes in a very compact housing and requires only 60mm space on the DIN-rail due to the high efficiency and low power losses. The high efficiency is achieved by utilizing cutting edge technology and other unique design techniques. SHORT-FORM DATA Output voltage DC 24V Adjustment range 24 - 28V Output current 8.3 – 7.1A continuous 12.5 – 10.7A for typ. 4s Output power 200W continuous 300W for typ. 4s Output ripple max. 50mVpp 20Hz to 20MHz AC Input voltage - - DC Input voltage DC 110V - 30%/ +40% DC Input current 1.96A at 110Vdc Inrush current typ. 4A peak at 110Vdc Efficiency 93.0% at 110Vdc Losses 15.0W at 110Vdc Temperature range -40°C to +70°C operational Derating - not required Hold-up time typ. 23ms at 110Vdc Dimensions 60x124x117mm WxHxD Weight 920g / 2.03lb ORDER NUMBERS DC/DC converter QS10.241-60 Accessory ZM13.SIDE Side mount bracket YR2.DIODE Redundancy module UF20.241 Buffer module MARKINGS EMC, LVD Aug. 2016 / Rev. 1.0 DS-QS10.241-60-EN All parameters are specified at 24V, 8.3A, 110Vdc, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany
Puls Dimension Q-Series Manual [PDF] (26 pages)
- Identifier: id-1669038
- Brand: Puls
- Device: Puls Dimension Q-Series Power Supply
- Type: Manual , PDF
- Key Aspects: Package Contents and Accessories List, Step-by-Step Assembly Procedures, System Limitations and Considerations
- UPD Date: 13.06.2026
- Source File: 1649688.pdf
- Pages: 26
- Description: Complete installation manual for the Puls Dimension Q-Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
QS3.241 Q-Series 24V, 3.4A, SINGLE PHASE INPUT Jul. 2020 / Rev. 2.3 DS-QS3.241-EN All parameters are specified at 24V, 3.4A, 230Vac, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany 1/26 POWER SUPPLY AC 100-240V Wide-range Input Width only 32mm Efficiency up to 90% 150% (120W) Peak Load Capability Easy Fuse Tripping due to High Overload Current Negligible low Inrush Current Surge Short-term Operation down to 60Vac and up to 300Vac Full Power Between -25°C and +60°C Quick-connect Spring-clamp Terminals 3 Year Warranty GENERAL DESCRIPTION The most outstanding features of this Dimension Q- Series DIN-rail power supply are the high efficiency and the small size, which are achieved by a synchronous rectification and further novel design details. The Q- Series is part of the Dimension family, existing alongside the lower featured C-Series. With short-term peak power capability of 150% and built-in large sized output capacitors, these features help start motors, charge capacitors and absorb reverse energy and often allow a unit of a lower wattage class to be used. High immunity to transients and power surges as well as low electromagnetic emission makes usage in nearly every environment possible. The integrated output power manager, a wide range input voltage design and virtually no input inrush current make installation and usage simple. Diagnostics are easy due to a green DC-ok LED and red overload LED. Unique quick-connect spring-clamp terminals allow a safe and fast installation and a large international approval package for a variety of applications makes this unit suitable for nearly every situation. SHORT-FORM DATA Output voltage DC 24V Adjustment range 24 - 28V Output current 3.4 – 3.0A continuous 5 – 4.5A for typ. 4s Output power 80W continuous 120W for typ. 4s Output ripple < 50mVpp 20Hz to 20MHz Input voltage AC 100-240V ±15% Mains frequency 50-60Hz ±6% AC Input current 1.42 / 0.82A at 120 / 230Vac Power factor 0.53 / 0.47 at 120 / 230Vac AC Inrush current typ. 5 / 10A peak at 120 / 230Vac Efficiency 88.7 / 90.0% at 120 / 230Vac Losses 10.4 / 9.1W at 120 / 230Vac Temperature range -25°C to +70°C operational Derating 2W/°C +60 to +70°C Hold-up time typ. 41 / 174ms at 120 / 230Vac Dimensions 32x124x102mm WxHxD ORDER NUMBERS Power Supply QS3.241 Mechanical Accessory ZM1.WALL Wall mount bracket ZM11.SIDE Side mount bracket MARKINGS UL508 UL 60950-1 Class I Div 2 Marine
Puls Dimension Q-Series Manual [PDF] (27 pages)
- Identifier: id-1669027
- Brand: Puls
- Device: Puls Dimension Q-Series Media Converter
- Type: Manual , PDF
- Key Aspects: Initial Startup Checklist, Pre-Installation Safety Requirements, FAQ Section for Common Queries
- UPD Date: 19.05.2026
- Source File: 1649699.pdf
- Pages: 27
- Description: Device instruction manual for the Puls Dimension Q-Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
QTD20.241 Q-Series 24V, 20A, DC INPUT DC/DC CONVERTER DC 600V Input Optimized for Intermediate DC-bus of Drive Systems Two Input Fuses for DC 600V included 95% Full Load and Excellent Partial Load Efficiencies Width only 65mm, Weight only 890g 25% BonusPower®, 600W for up to 4s Active Filtering of Input Transients Full Power Between -25°C and +60°C Extremely Low Input Inrush Current Surge Reverse Input Polarity Protection DC-OK Relay Contact Quick-connect Spring-clamp Terminals 3 Year Warranty 1/27 GENERAL DESCRIPTION Modern machines typically use maintenance-free AC- motors which are controlled by frequency converters or servo amplifiers. Such devices have an intermediate DC- bus where all individual drives are connected. The QTD20 DC/DC converter can be connected directly to the intermediate DC-bus. In case of a mains failure, the QTD20 utilizes the power from the DC-bus capacitors which are charged from the kinetic energy of the motor until the motor has come to a complete stop. The intermediate DC-bus is usually unfiltered and have high EMI noise so the QTD20 has a very robust input stage and an appropriate input filter included. Additionally, the QTD20 is UL 508 approved and is equipped with input fuses which are rated and tested for 600Vdc applications. SHORT-FORM DATA Output voltage DC 24V nominal Adjustment range 24 - 28V Output current 20 – 17.5A continuous 25 – 21.4A short term (4s) Output power 480W continuous 600W short term (4s) Output ripple < 100mVpp 20Hz to 20MHz Input voltage DC 600V -20%/+40% Input current 0.85A at 600Vdc Inrush current typ. 1.5A peak Efficiency 95.0% at 600Vdc Losses 25.5W at 600Vdc Temperature range -25°C to +70°C operational Derating 12W/°C +60 to +70°C Hold-up time typ. 22ms at 600Vdc Dimensions 65x124x127mm WxHxD Weight 890g / 1.96lb L1 L2 L3 PE f Motor PE + DC Load, Controller QTD+ - + - PE f Motor ORDER NUMBERS DC/DC converter QTD20.241 Accessory ZM1.WALL Wall mount bracket ZM14.SIDE Side mount bracket UF20.241 Buffer unit YR40.241 Redundancy module MARKINGS IND. CONT. EQ. UL 508 EMC, LVD Oct. 2016 / Rev. 2.0 DS-QTD20.241-EN All parameters are specified at 24V, 20A, 600Vdc input, 25°C ambient and after a 5 minutes run-in time unless otherwise noted. www.pulspower.com Phone +49 89 9278 0 Germany
Similar Manuals in the Media Converter, Power Supply Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Vogel FALKE |
FALKE Operation & user’s manual - Q77525 |
31 | 1245 | 287 | 30-03-2026 | view all manuals | |
CYP CLUX-SDI2CSS |
CYP CLUX-SDI2CSS User Guide (Operation manual), @8G4KA9 |
20 | 762 | 183 | 08-03-2026 | view all manuals | |
ALFAtron ALF-SUK4T |
Manual: ALFAtron ALF-SUK4T (NRIO91, Upd.31-07-2026) |
19 | 1113 | 256 | 31-07-2026 | view all manuals | |
Planet GTP-805A |
Media Converter #4F2282 |
24 | 987 | 149 | 01-04-2026 | view all manuals | |
Altronix eBridge100STR |
PDF Manual (@668B26), Altronix eBridge100STR Adapter (30-05-2026) |
4 | 609 | 128 | 30-05-2026 | view all manuals | |
ELGO Electronic FMax Series |
PDF Guide (@963LV8), ELGO Electronic FMax Series Media Converter (09-03-2026) |
20 | 157 | 38 | 09-03-2026 | view all manuals |