red lion LD Manuals

2 pdf manual(s) red lion LD for free download (Document Types: Manual , Operation & user’s manual)

red lion LD Manual  Thumbnail

red lion LD Manual  [PDF] (16 pages)

  • Identifier: id-861303
  • Brand: red lion
  • Device: red lion LD Monitor
  • Type: Manual , PDF
  • Key Aspects: Best Practices for Everyday Use, Technical Support and Resource Links, Product Performance Metrics
  • UPD Date: 05.07.2026
  • Source File: 883270.pdf
  • Pages: 16
  • Description: User reference manual for the red lion LD.
Pages Preview:
  • red lion LD Manual  preview - page 2
  • red lion LD Manual  preview - page 3
  • red lion LD Manual  preview - page 4
  • red lion LD Manual  preview - page 5
  • red lion LD Manual  preview - page 6
  • red lion LD Manual  preview - page 7
  • red lion LD Manual  preview - page 8
  • red lion LD Manual  preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 AIR PRESSURE STABILIZATION VENT (57.15) 2.25 X Z Y GENERAL DESCRIPTION The Large Display is a versatile display that can be configured as a single or dual counter with rate indication, scaling, serial communications and a dual relay output. There are also basic models that have a single counter with direction control only (no scaling or relay output). The 4 & 6 digit displays are available in either 2.25" or 4" high red LED digits with adjustable display intensities. The 2.25" high models are readable up to 130 feet. The 4" high models are readable up to 180 feet. All versions are constructed of a NEMA 4X/IP65 enclosure in light weight aluminum. The 6-digit programmable models have two signal inputs and a choice of eight different count modes. These include bi-directional, quadrature and anti- coincidence counting, as well as a dual counter mode. When programmed as a dual counter, each counter has separate scaling and decimal point selection. Rate indication is available on the programmable models only. The rate indicator has separate scaling and decimal point selection, along with programmable display update times. The meter display can be toggled either manually or automatically between the count and rate values. The programmable models also come with a dual Form C relay output and RS232 or RS485 serial communications. The outputs can activate based on either counter or rate setpoint values. An internal batch counter can be used to count setpoint output activations. SAFETY SUMMARY All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. Do not use this unit to directly command motors, valves, or other actuators not equipped with safeguards. To do so can be potentially harmful to persons or equipment in the event of a fault to the unit. The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system. SPECIFICATIONS 1. DISPLAY: 2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED 2. POWER REQUIREMENTS: AC POWER: 50 to 250 VAC 50/60 Hz, 26 VA DC POWER: 21.6 to 250 VDC, 11 W DC OUT: +24 VDC @ 100 mA if input voltage is greater than 50 VAC/VDC +24 VDC @ 50 mA if input voltage is less than 50 VDC Isolation: 2300 VRMS for 1 min. to all inputs and outputs 3. COUNT INPUT(S): Counter(s) have DIP switch selectable pull-up (7.8 K) or pull-down resistors (3.9 K) that determine active high or active low input logic. Counters are DIP switch selectable for high or low frequency (Damping capacitor provided for switch contact bounce. Limits input frequency to 50 Hz and input pulse widths to 10 msec min.) Input A Trigger levels: VIL = 1.25 V max; VIH = 2.75 V min; VMAX = 28 VDC Input B Trigger levels: VIL = 1.0 V max; VIH = 2.4 V min; VMAX = 28 VDC Overflow Indication: Display “” alternates with overflowed count value. LD200400, LD200600, LD400400, & LD400600: Count Rate: 25 KHz max. @ 50% duty cycle (no scaling) LD2006P0 & LD4006P0: Maximum Count Rates: 50% duty cycle, count mode dependent. With setpoints disabled: 25 KHz, all modes except Quadrature x4 (23 KHz). With setpoint(s) enabled: 20 KHz, all modes except Dual Counter (14 KHz), Quadrature x2 (13 KHz) and Quadrature x4 (12 KHz). 4. RATE INPUT: Models LD2006P0 & LD4006P0 only Display Range: 0 to 99999 Min Freq.: 0.01 Hz Max Freq.: See Count Input specification Accuracy: ±0.01% Rate Overflow Indication: Display “”  2.25" & 4" HIGH RED LED DIGITS  AVAILABLE IN 4 OR 6 DIGIT VERSIONS  SINGLE OR DUAL COUNTER with RATE INDICATOR *  PROGRAMMABLE SCALING AND DECIMAL POINTS *  BUILT-IN BATCH COUNTING CAPABILITY *  PROGRAMMABLE USER INPUT *  UNIVERSALLY POWERED  DUAL 5 AMP FORM C RELAY *  ALUMINUM NEMA 4X CASE CONSTRUCTION * Programmable models only MODEL LD - LARGE DISPLAY DIMENSIONS In inches (mm) Bulletin No. LD-K Drawing No. LP0607 Released 05/11 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net PART NUMBER X (Length) Z (Center) LD2004xx 12 (304.8) 8 (203.2) 4 (101.6) LD2006xx 16 (406.4) LD4004xx 20 (508) LD4006xx 26 (660.4) 22 (558.8) CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. 16 (406.4) 12 (304.3) 4 (101.6) Y (Height) 7.875 (200) 7.875 (200) C US LISTED US LISTED UL R 51EB IND. CONT. EQ.
red lion LD Operation & user’s manual Thumbnail

red lion LD Operation & user’s manual [PDF] (16 pages)

  • Identifier: id-1399266
  • Brand: red lion
  • Device: red lion LD Timer
  • Type: Operation & user’s manual, PDF
  • Key Aspects: Basic Configuration Guidelines, Regulatory Compliance and Standards, Hardware Setup Instructions
  • UPD Date: 09.05.2026
  • Source File: 1328488.pdf
  • Pages: 16
  • Description: Advanced user manual for the red lion LD.
Pages Preview:
  • red lion LD Operation & user’s manual preview - page 2
  • red lion LD Operation & user’s manual preview - page 3
  • red lion LD Operation & user’s manual preview - page 4
  • red lion LD Operation & user’s manual preview - page 5
  • red lion LD Operation & user’s manual preview - page 6
  • red lion LD Operation & user’s manual preview - page 7
  • red lion LD Operation & user’s manual preview - page 8
  • red lion LD Operation & user’s manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
1 GENERAL DESCRIPTION The Large Display Timer and Cycle Counter is a versatile display that functions as an Elapsed Timer or Preset Timer, with full-featured user programmability. The meter includes a built-in Cycle Counter, relay output and serial communications capability. The 6 digit displays are available in either 2.25" or 4" high red LED digits with adjustable display intensity. The 2.25" high models are readable up to 130 feet. The 4" high models are readable up to 180 feet. Both versions are constructed of a NEMA 4 enclosure in light weight aluminum. The Timer has two signal inputs and eight input operating modes. These modes provide level active or edge triggered start/stop operation. The Timer features 18 selectable timer ranges to cover a wide variety of timing applications. The built-in Cycle Counter can be linked to timer operation to count timing cycles, or function as a totally independent counter, accepting count speeds up to 500 Hz. The display can be toggled either manually or automatically between the Timer and Counter values. In addition to the Timer/Counter inputs, a programmable User Input is provided to perform a variety of meter functions. DIP switches are used to configure the inputs for current sinking (active low) or current sourcing (active high) operation. The Setpoint Output can be assigned to the Timer or Counter value, and configured to suit a variety of control and alarm requirements. The meter also includes jumper selectable RS232 or RS485 serial communications. SAFETY SUMMARY All safety regulations, local codes and instructions that appear in this and corresponding literature, or on equipment, must be observed to ensure personal safety and to prevent damage to either the instrument or equipment connected to it. If equipment is used in a manner not specified by the manufacturer, the protection provided by the equipment may be impaired. The protective conductor terminal is bonded to conductive parts of the equipment for safety purposes and must be connected to an external protective earthing system. SPECIFICATIONS 1. DISPLAY: 2.25" (57 mm) or 4" (101 mm) intensity adjustable Red LED 2. POWER REQUIREMENTS: AC Power: AC Input: 85 to 250 VAC 50/60 Hz, 14 VA DC Out: 11 to 16 VDC @ 50 mA (consult factory for higher current draw) DC Power: DC Input: 11 to 16 VDC @ 400 mA max, 7 W 3. TIMER DISPLAY: 6-digits Display Range: 0 to 999999 Overflow/Underflow Indication: Display flashes “! #$%&” Minimum Digit Resolution: 0.001 Sec. Maximum Single Digit Resolution: 1 Hr. Timing Accuracy: ±0.01% 4. CYCLE COUNTER DISPLAY: 5-digits, may be disabled if not used Display Designator: “'” to the left side of the display Display Range: 0 to 99999 Overflow/Underflow Indication: Display flashes “' #$%&” ! 2.25" or 4" HIGH RED LED DIGITS ! 6-DIGIT BI-DIRECTIONAL TIMING CAPABILITY ! 5-DIGIT CYCLE COUNTING CAPABILITY ! SELECTABLE TIMER RANGES AND OPERATING MODES ! ELAPSED TIMER AND PRESET TIMER FUNCTIONALITY ! SERIAL COMMUNICATIONS (SELECTABLE RS232 or RS485) ! PROGRAMMABLE USER INPUT ! AC OR DC POWERED ! 5 AMP FORM C RELAY OUTPUT ! ALUMINUM NEMA 4X CASE CONSTRUCTION MODEL LD - LARGE DISPLAY TIMER AND CYCLE COUNTER DIMENSIONS In inches (mm) Bulletin No. LDT-B Drawing No. LP0634 Released 9/06 Tel +1 (717) 767-6511 Fax +1 (717) 764-0839 www.redlion.net X (Length) LD2T06P0 16 (406.4) LD4T06P0 26 (660.4) 7.875 (200) CAUTION: Risk of Danger. Read complete instructions prior to installation and operation of the unit. CAUTION: Risk of electric shock. 12 (304.8) 4 (101.6) C US LISTED US LISTED UL R IND. CONT. EQ. 51EB PART NUMBER Z (Center) Y (Height) 22 (558.8)

Similar Manuals in the Monitor, Timer Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
SEBSON A1

PDF Manual (@4HX39Q), SEBSON A1 Timer (21-07-2026)

21 875 167 21-07-2026 view all manuals
Bticino F67SR11

Switch #15S6D9

4 127 28 05-05-2026 view all manuals
Omron H5BR Series

PDF Guide (@92Z494), Omron H5BR Series Timer (20-07-2026)

15 895 162 20-07-2026 view all manuals
Orbit timer

Orbit Timer Manual  (File: PDF, 16-03-2026)

2 1339 295 16-03-2026 view all manuals
Orbis DATA MULTI ANUAL

DATA MULTI ANUAL Manual user - 2973V3

2 648 150 07-05-2026 view all manuals
Vincent Associates VMM-T1

VMM-T1 Operation & user’s manual - Z3R14M

43 1299 273 02-08-2026 view all manuals