Robertshaw RS6110 Manuals

6 pdf manual(s) Robertshaw RS6110 for free download (Document Types: Installation manual, Operation & user’s manual, Specifications)

Available Documents for RS6110:

Robertshaw RS6110 Installation manual Main Page Preview

Installation manual [PDF] (32 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: Critical Operational Precautions, Package Contents and Accessories List, Step-by-Step Assembly Procedures
  • Updated: 04.09.2026
  • Source File: 706151.pdf
  • Pages: 32
  • Description: Operation instructions for the Robertshaw RS6110.
Robertshaw RS6110 Installation manual Main Page Preview

Installation manual [PDF] (14 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: Performance Optimization Tips, Device Specifications Overview, FAQ Section for Common Queries
  • Updated: 06.05.2026
  • Source File: 320600.pdf
  • Pages: 14
  • Description: Product documentation for the Robertshaw RS6110.

Document Preview & Text Transcription

Thank you for purchasing a Robertshaw® thermostat. This manual will describe how to install and test the Robertshaw single stage thermostats RS4110, RS5110, RS6110, and two stage RS4220, RS5220, RS6220 thermostats. For complete operation instructions, refer to the Robertshaw User Manual. Use the model number to identify your thermostat. These thermostats have three main parts: A. The backplate – mounts to the wall and has wire connections. B. The body – snaps to the backplate and contains the electronics and programming buttons. C. The cover – snaps to the top of the body and swings up to give access to the programming buttons. Recycling Thermostat If this thermostat is replacing a thermostat that contains mercury in a sealed tube, do not place your old thermostat in the garbage. Contact your local waste management authority for instructions regarding proper disposal of the thermostat. If you have any questions, call Robertshaw technical support at 1-800-445-8299. 1 RS4110 RS5110 RS6110 RS4220 RS5220 RS6220 R S X 1 1 0 4 = Non-Programmable Value Series 5 = Programmable Value Series with 5-2 Day Schedule 6 = Programmable Value Series with 7 Day Schedule and Copy Feature Application 0 = Standard Thermostat Number of Cooling Stages Number of Heating Stages INSTALLATION MANUAL RS4000 Series RS5000 Series RS6000 Series 352-00060-001 Rev. A IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • This is a 24 VAC low-voltage thermostat. Do not install on voltages higher than 30 VAC. • All wiring must conform to local and national building and electrical codes and ordinances. • To take advantage of the Pop-Up Wizard, power should be applied when the settings are ready to be entered. Fill in the chart in the Pop-Up Wizard section before applying power. • This is a dual powered thermostat that will operate on 24 VAC or batteries. • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. • Do not connect ground to any terminal in this unit. • This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages. Short cycle protection provides a delay between compressor cycles on heat pumps. Replacing Existing Thermostat 1. Turn off power to heating and cooling system. 2. Remove cover from old thermostat to expose wires. 3. Disconnect wires one at a time from existing terminals. Use enclosed labels to mark existing wires. Refer to cross references in Table 1 if existing wiring does not directly match the labels. 4. Remove existing thermostat base from wall. Table 1 Old Terminal New Label Description R, RH/R, V-VR or VR-R R/RH 24V AC Return RC RC 24V AC Cooling Transformer Y, Y1 or M Y1 1st Stage Cooling Circuit F or G G Fan Control Relay Y2 Y2 2nd Stage Cooling Circuit W2 or W-U W2 2nd Stage Heating Control C, X or B C 24V AC Transformer Common Side W1 or W W1 1st Stage Heating Circuit 2 Installing the Robertshaw Thermostat Base NOTE: For new installations, mount the thermostat on an inside wall, five feet above the floor. Do not install behind a door, in a corner, near air vents, in direct sunlight, or near any heat or steam generating fixtures. Installation at these locations will affect thermostat operation. 1. Be certain power is off to the heating and cooling systems. 2. Remove the backplate by placing your finger through the wire opening. Pull the backplate straight out from the body. 3. Place the backplate in position on the wall. Pull the wires through the wire opening. 4. Hold the backplate level and mark the mounting holes on the wall. 5. Drill the marked holes using a 5 mm (3/16 in.) drill bit. 6. Tap in the wall anchors and secure the base to the wall with the supplied screws. NOTE: The thermostats are designed to also mount on a single gang junction box. Providing Power to the Thermostat To take advantage of the Pop-Up Wizard, power should be applied when the settings are ready to be entered. Fill in the chart in the Pop-Up Wizard section before applying power. These thermostats will run on either two AA batteries or 24 VAC. If the common wire from the transformer is not available, the unit must be powered by two AA batteries. Thermostats with batteries and powered by 24 VAC will continue to function if the 24 VAC fails. Maintaining the Batteries When the batteries are low, the thermostat will enter a low power mode. Low battery mode has two levels. • LEVEL 1: The low battery icon will be displayed. • LEVEL 2: The low battery icon will flash indicating that THE SYSTEM WILL NOT OPERATE. 3 Wiring Terminals Mounting Holes Wire Opening RH/R RC C L G O B Y1 W1 Y2 W2 E
Robertshaw RS6110 Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (32 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: System Architecture and Design Overview, Device Specifications Overview, Model Variations and Compatibility
  • Updated: 15.03.2026
  • Source File: 320597.pdf
  • Pages: 32
  • Description: Detailed user guide for the Robertshaw RS6110.

Document Preview & Text Transcription

Thank you for purchasing a Robertshaw RS5000 Series programmable thermostat. This user’s manual will guide you through the setup of the RS5110 single stage and the RS5220 two stage thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently. Before making any changes to the schedule read the section on Default Settings. Features • Pop-Up Wizard • Automatic changeover • Circulating fan • Worry-Free memory retention • Easy change battery • Large back lit display • Filter change reminder • Low battery indicator • Fahrenheit and Celsius displays • EnergyStar™ compliant • Dual power • Adjustable 1st stage temperature differential: 0.5 F degrees to 3.0 F degrees (0.5 C degrees to 1.5 C degrees) • Accuracy within ±1 F degree • Universal staging on multi-stage units • Automatic heating shutdown if temperature exceeds 99°F (37°C) • Keypad security lockout • 4 events per day for heating and cooling • 5-2 day scheduling • User settable Hi and Lo temperature limits • Vacation setpoint override 1 RS4110 RS5110 RS6110 RS4220 RS5220 RS6220 352-00056-001 USERS MANUAL Application The Robertshaw 5000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS5110 is a single stage thermostat while the RS5220 is a two-stage thermostat. The RS5000 thermostats use 5-2 programming. This means the 5 weekdays will operate on one schedule and the 2 weekend days will operate on a second schedule. IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC. • All wiring must conform to local and national building and electrical codes and ordinances. • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. • Do not connect ground to any terminal in this unit. • This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages. Short cycle protection provides a delay between heating and cooling cycles on heat pumps. Detailed mounting and wiring instructions are explained in the Installation Manual Refer to the Pop-Up Wizard section in the Installation Manual for a complete list of factory defaults and contractor settings. Providing Power to the Thermostat For wiring diagrams refer to the Installation Manual. The thermostats will operate using 24V AC or two AA batteries. When the two AA batteries are installed the thermostat will continue to run if the 24V AC fails. ! 2 Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides. The battery compartment will pull down from the thermostat body and will detach. Install two AA batteries following the polarity as shown inside the compartment. Place the compartment back into the thermostat. When the batteries are low the thermostat will enter a low battery mode. Low battery mode has two levels. • LEVEL 1: The low battery icon will be displayed. The thermostat will continue to operate. Replace the batteries as soon as possible • LEVEL 2: The low battery icon will flash. If 24V AC is present the thermostat will continue to operate if the batteries are discharged or removed. If 24V AC is not present the thermostat runs on batteries only and THE SYSTEM WILL NOT OPERATE. Replace batteries immediately. The clock will continue to run for 10 minutes when the batteries are removed. Replace batteries if leaving thermostat unattended for more than 30 days. Display Map The thermostat display will show information that is being used during operation or programming. This illustration shows all of the display’s possibilities with an explanation. 2 1. Event names (used for editing schedule). 2. Day is displayed on IDLE screen. Also used to display day ranges when editing the schedule (e.g., SAT SUN for weekend). 3. Used with clock to display hold duration (e.g., FOR 2h). 4. Displayed when running a schedule. 5. Used with setpoint. 6. Used along with clock for service reminders (e.g., CHECK HP). 7. Used for time, current setpoint, and some configuration data (e.g., filter hours). 8. HVAC mode and status. Icons blink when active. A is for Auto, 2 is for second stage, E is for emergency, is for heating, and is for cooling. 9. Indicates when security is active. 10. Low battery indicator. 11. Displayed when in vacation hold. 12. Used for ambient temperature and configuration data (e.g., first stage differential, F or C, etc.). 13. Fan status (rotates when active). 14. Fan use (selected by pressing FAN button). 5 3 4 1 6 7 8 9 10 12 11 13 14 3
Robertshaw RS6110 Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (32 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: Regulatory Compliance and Standards, Step-by-Step Assembly Procedures, Performance Optimization Tips
  • Updated: 25.06.2026
  • Source File: 320607.pdf
  • Pages: 32
  • Description: Instruction guidebook for the Robertshaw RS6110.

Document Preview & Text Transcription

Thank you for purchasing a Robertshaw RS6000 programmable thermostat. This user’s manual will guide you through the setup of the RS6110 single stage and the RS6220 two stage thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently. Before making any changes to the schedule read the section on Default Settings. Features • Pop-Up Wizard • Automatic changeover • Circulating Fan • Worry-Free memory retention • Easy change battery • Large back lit display • Filter change reminder • Low battery indicator • Fahrenheit and Celsius displays • EnergyStar™ compliant • Dual power • Adjustable 1st stage temperature differential: 0.5 F Degrees to 3.0 F Degrees (0.5 C Degrees to 1.5 C Degrees) • Accuracy within ±1 F Degree • Universal staging on multi-stage units • Automatic heating shutdown if temperature exceeds 99°F (37°C) • Keypad security lockout • 4 events per day for heating and cooling • Individual day scheduling • User settable Hi and Lo temperature limits 1 RS6110 RS6220 352-00057-001 USERS MANUAL Application The Robertshaw 6000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS6110 is a single stage thermostat while the RS6220 is a two-stage thermostat. The RS6000 thermostats can have a schedule programmed for each day. IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC. • All wiring must conform to local and national building and electrical codes and ordinances. • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. • Do not connect ground to any terminal in this unit. • This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages. Short cycle protection provides a delay between heating and cooling cycles on heat pumps. Detailed mounting and wiring instructions are explained in the Installation Manual. Refer to the pop up wizard section in the installation manual for a complete list of factory defaults and contractor settings. Providing Power to the Thermostat For wiring diagrams refer to the Installation Manual. The thermostats will operate using 24V AC or two AA batteries. When the two AA batteries are installed the thermostat will continue to run if the 24V AC fails. ! 2 Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides. The battery compartment will pull down from the thermostat body and will detach. Install two AA batteries following the polarity as shown inside the compartment. Place compartment back into the thermostat. When the batteries are low the thermostat will enter a low battery mode. Low battery mode has two levels. • LEVEL 1: The low battery icon will be displayed. The thermostat will continue to operate. Replace the batteries as soon as possible • LEVEL 2: The low battery icon will flash. If 24V AC is present the thermostat will continue to operate if the batteries are discharged or removed. If 24V AC is not present the thermostat runs on batteries only and THE SYSTEM WILL NOT OPERATE. Replace batteries immediately. The clock will continue to run for 10 minutes when the batteries are removed. Replace batteries if leaving thermostat unattended for more than 30 days. Display Map The thermostat display will show information that is being used during operation or programming. This illustration shows all of the display’s possibilities with an explanation. 3 2 1. Event Names (used for editing schedule). 2. Day is displayed on Idle screen. Also used to display day ranges when editing the schedule (e.g., SAT SUN for weekend). 3. Used with clock to display hold duration (e.g., FOR 2h). 4. On when running a schedule. 5. Used with setpoint. 6. Used along with clock for service reminders (e.g., CHECK HP). 7. Used for time, current setpoint, and some configuration data (e.g., filter hours). 8. HVAC mode and status. Icons blink when active. A is for Auto, 2 is for second stage, E is for emergency. 9. Indicates when security is active. 10.Low battery indicator. 11.Not used. 12.Used for ambient temperature and configuration data (e.g., first stage differential, F or C, etc.). 13.Fan status (rotates when active). 14.Fan use selected by pressing FAN button. 5 3 4 1 6 7 8 9 10 12 11 13 14
Robertshaw RS6110 Specifications Main Page Preview

Specifications [PDF] (2 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: Device Specifications Overview, Cleaning and Sanitization Methods, System Connectivity and Wiring Basics
  • Updated: 13.06.2026
  • Source File: 320636.pdf
  • Pages: 2
  • Description: Instruction and reference manual for the Robertshaw RS6110.

Document Preview & Text Transcription

7 Day Programmable RS6110 – 1 Heat / 1 Cool RS6220 – Universal Control up to 2 Heat / 2 Cool RS6320 – Universal Control up to 3 Heat / 2 Cool G GAS E ELECTRIC O OIL H HEAT PUMP 5 Year Limited Warranty An ISO 9001 – 2000 Certified Company Seven Day Comfort Control Simplified The Robertshaw® RS6000 thermostat family is Simply the Right Choice™when it comes to daily programmable temperature controls that can save energy and money. With the comfort, convenience, and efficiency features that homeowners and contractors want, the RS6000 family provides EnergyStar® and California Title 24 compliant features for an affordable price. • Fully programmable with soft touch keys to easily set four events per day AND 7 day scheduling. • Copy command that makes programming simple to set up and flexible to use. • Pop-Up Wizard to customize thermostat settings with an instant start-up menu. The RS6000 thermostats are fully compatible with all standard 24V AC heating and cooling systems. Additional compatibility with multi-stage gas/electric furnaces and heat pump systems are available in the RS6220 and RS6320 models. Add in easy installation, Contractor ID option, and quality you can depend on, and you have the Robertshaw RS6000 thermostat family - Simply the Right Choice. Features and Benefits Universal Control up to 2 Heat / 2 Cool – RS6220 only Universal Control up to 3 Heat / 2 Cool – RS6320 only Operates on both multi-stage gas/electric furnaces and heat pumps means less inventory. Auto Changeover Switches automatically between heating and cooling for constant home comfort. Pop-Up Wizard Launches instant installation menu to quickly enter the settings for programmed thermostat functions. Bigger Brighter Backlight with Nightlight Option Makes viewing and setting the temperature easier any time of the day. Worry-Free Memory Retention Maintains set point and programmed parameters, even during power outages. Easy Change Battery Access Provides drop down removable compartment for quick battery replacement. Circulating Fan Maintains optimal air circulation between demand cycles for improved comfort with minimal energy use. Low Temperature Freeze Protection Turns on heat automatically when temperature goes below 41°F. Protects pipes from freezing. Adjustable Temperature Differential and Upstaging Provides for full selection of parameters to deliver maximum comfort or energy savings. High and Low Setpoint Limits Protects the heating and cooling systems by limiting temperature settings. M MILLIVOLT 24V AC POWERED WITH BATTERY BACK-UP BATTERY OPERATED - OR - VALUE SERIES DIGITAL PROGRAMMABLE THERMOSTATS RS6110 RS6220 RS6320 191 E. North Avenue Carol Stream Illinois 60188 USA Customer Service Telephone 1.800.304.6563 Customer Service Facsimile 1.951.737.8261 [email protected] www.RobertshawTstats.com www.invensyscontrols.com ©2008 Invensys Controls For Technical Service Telephone 1.800.445.8299 Facsimile 1.630.260.7243 [email protected] 3505 Laird Road Unit #14 Mississauga Ontario L5L 5Y7 Canada Customer Service Telephone 1.800.387.7978 Customer Service Facsimile 1.905.828.1265 [email protected] Invensys®, Robertshaw® and Simply the Right Choice™ are trademarks of Invensys plc., its subsidiaries and/or affiliated companies. All other brands mentioned in this report may be the trademarks of their respective owners. 2/08 – 150-2091B RH/R 24V AC Transformer (Heating) C 24V AC Common RC 24V AC Transformer (Cooling) G Fan Relay B Heat Active Reversing Valve O Cool Active Reversing Valve Y1 Cooling Relay (Stage 1) W1 Heating Relay (Stage 1) RS6110 Braeburn® 5000, 5050 Honeywell TH6110D White-Rodgers 1F80-0471 RS6220 Braeburn® 5300 Lux PSPA722E Honeywell TH6220D White-Rodgers 1F85-0471 RS6320 Honeywell TH6320D White-Rodgers 1F85-0471 Product Weight 12.8 oz. Electrical Rating 24V AC (18-30V AC) 1 amp maximum load per terminal 3 amp total maximum load (all terminals combined) Temp. Control Range 45°F to 90°F (7°C to 32°C) Accuracy ± 1°F (± 0.5°C) Power 24V AC with battery back-up OR 3.0V DC (2 AA alkaline batteries included) System Configurations Two stage gas, electric, oil, millivolt, and up to three stage heat pump systems Terminations RS6110 – RH/R, RC, C, G, B, O, Y1, W1 RS6220 / RS6320 – RH/R, RC, C, G, B, O, Y1, W1, Y2, W2, E, L Individual Carton Dimensions 6.75" x 4.375" x 1.625" Master Carton Quantity 6 Master Carton Dimensions 9.25" x 5.625" x 7.625" Master Carton Weight 5 lbs. Pallet Quantity 1170 Pallet Dimensions 40" x 48" x 48" Technical Specifications Terminal Designations Replacement Chart Verify specific application requirements before substitution. RH/R 24V AC Transformer (Heating) C 24V AC Common RC 24V AC Transformer (Cooling) G Fan Relay B Heat Active Reversing Valve O Cool Active Reversing Valve Y1 Cooling Relay (Stage 1) W1 Heating Relay (Stage 1) Y2 Cooling Relay (Stage 2) W2 Heating Relay (Stage 2) E Emergency or 3rd Stage Heating Relay L System Monitor RS6110 RS6220 and RS6320 VALUE SERIES DIGITAL PROGRAMMABLE THERMOSTATS RS6110 RS6220 RS6320 Shipping Specifications
Robertshaw RS6110 Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (32 pages)

  • Brand: Robertshaw
  • Model: RS6110
  • Format: PDF
  • Key Aspects: FAQ Section for Common Queries, Package Contents and Accessories List, Hardware Setup Instructions
  • Updated: 20.08.2026
  • Source File: 320635.pdf
  • Pages: 32
  • Description: Full user manual for the Robertshaw RS6110.

Document Preview & Text Transcription

1 Thank you for purchasing a Robertshaw RS6000 programmable thermostat. This user’s manual will guide you through the setup of the RS6110 single stage, the RS6220 two stage and the RS6320 three stage* thermostats. The thermostat should already be mounted and correctly wired. The default settings will enable the thermostat to operate efficiently. Before making any changes to the schedule read the section on Default Settings. Features • Pop-Up Wizard • Automatic changeover • Circulating Fan • Worry-Free memory retention • Easy change battery • Large back lit display • Filter change reminder • Low battery indicator • Fahrenheit and Celsius displays • EnergyStar™ compliant • Dual power • Adjustable 1st stage temperature differential: 0.5 °F to 3.0 °F (0.5 °C to 1.5 °C) • Accuracy within ±1 °F • Universal staging on multi-stage units • Automatic heating shutdown if temperature exceeds 99 °F (37 °C) • Keypad security lockout • 4 events per day for heating and cooling • Individual day scheduling • User settable Hi and Lo temperature limits RS6110 RS6220 RS6320 352-00057-001 Rev B USERS MANUAL * Three stage heating available for heat pump applications only. 2 Application The Robertshaw 6000 family of thermostats is designed to control gas, electric, oil, heat pump, and millivolt heating and electric cooling systems. The RS6110 is a single stage thermostat while the RS6220 is a two-stage thermostat. The RS6320 can support three stages of heating and two stages of cooling in heat pump applications. The RS6000 thermostats can have a schedule programmed for each day. IMPORTANT SAFETY INFORMATION WARNING: • Always turn off power at main fuse or circuit breaker panel before installing, removing, cleaning, or servicing thermostat. • Read all the information in this manual before installing this thermostat. • This is a 24V AC low-voltage thermostat. Do not install on voltages higher than 30V AC. • All wiring must conform to local and national building and electrical codes and ordinances. • Do not short (jumper) across terminals on the gas valve or at the system control to test installation. This will damage the thermostat and void the warranty. • Do not connect ground to any terminal in this unit. • This thermostat is configured with automatic compressor protection to prevent damage because of short cycling or extended power outages. Short cycle protection provides a delay between heating and cooling cycles on heat pumps. Detailed mounting and wiring instructions are explained in the Installation Manual. Refer to the Pop-Up Wizard section in the installation manual for a complete list of factory defaults and contractor settings. Providing Power to the Thermostat For wiring diagrams refer to the Installation Manual. The thermostats will operate using 24V AC or two AA batteries. When the two AA batteries are installed the thermostat will continue to run if the 24V AC fails. 3 Installing or Changing the Batteries To remove the battery compartment gently squeeze the ribbed edges on both sides. The battery compartment will pull down from the thermostat body and will detach. Install two AA batteries following the polarity as shown inside the compartment. Place compartment back into the thermostat. When the batteries are low the thermostat will enter a low battery mode. Low battery mode has two levels. • LEVEL 1: The low battery icon will be displayed. The thermostat will continue to operate. Replace the batteries as soon as possible • LEVEL 2: The low battery icon will flash. If 24V AC is present the thermostat will continue to operate if the batteries are discharged or removed. If 24V AC is not present the thermostat runs on batteries only and THE SYSTEM WILL NOT OPERATE. Replace batteries immediately. Replace batteries if leaving thermostat unattended for more than 30 days. The clock will continue to run for 10 minutes when the batteries are removed. Display Description The thermostat display will show information that is being used during operation or programming. This illustration shows all of the display’s possibilities with an explanation. 2 1. Event Names (used for editing schedule). 2. Day is displayed on Idle screen. Also used to display day ranges when editing the schedule (e.g., SAT SUN for weekend). 3. Used with clock to display hold duration (e.g., FOR 2h). 4. On when running a schedule. 5. Used with setpoint. 6. Used along with clock for service reminders (e.g., CHECK HP). 7. Used for time, current setpoint, and some configuration data (e.g., filter hours). 8. HVAC mode and status. Icons blink when active. A is for Auto, 2 is for second stage, E is for emergency. 9. Indicates when security is active. 10.Low battery indicator. 11.Not used. 12.Used for ambient temperature and configuration data (e.g., first stage differential, F or C, etc.). 13.Fan status (rotates when active). 14.Fan mode selected by pressing FAN button. 5 3 4 1 6 7 8 9 10 12 11 13 14

RS6110: Related Instructions

Manuals from Other Manufacturers