Salus HTR230 Manuals
1 pdf manual(s) Salus HTR230 for free download (Document Types: Installer manual)
Salus HTR230 Installer manual [PDF] (2 pages)
- Identifier: id-2327177
- Brand: Salus
- Device: Salus HTR230 Thermostat
- Type: Installer manual, PDF
- Key Aspects: Periodic Inspection Checklists, Detailed Installation Instructions, Regulatory Compliance and Standards
- UPD Date: 17.05.2026
- Source File: 1960428.pdf
- Pages: 2
- Description: Advanced user guide for the Salus HTR230.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Dial Thermostat Model: HTR230 INSTALLER MANUAL SALUS Controls plc SALUS House Dodworth Business Park South, Whinby Road, Dodworth, Barnsley S75 3SP, UK. Sales: T: +44 (0) 1226 323961 E: [email protected] Technical: T: +44 (0) 1226 323961 E: [email protected] www.salus-controls.com SALUS Controls is a member of the Computime Group Maintaining a policy of continuous product development SALUS Controls plc reserve the right to change specification, design and materials of products listed in this brochure without prior notice. Issue Date: Dec 2015 00190 For PDF Installation guide please go to www.salus-manuals.com 8. Technical Specification Model: HTR230 Voltage: 230 V AC, +-10%, 50/60 Hz Temperature setback: Temperature range: 2°C-4°C 5°C- 30°C Span: +/- 0,5°C Calibration: Yes, with jumper Storage temperature: -20°C to +60°C Ambient temperature: 0 °C up to 45 °C Degree of protection: IP 30 CE conformity according to: Class II ( EN60730 ) Housing material: PC, V2 Color: RAL 9010 pure white Connection: Screw terminal Weight 90g net / 135g gross Puls-wide-modulation: (PWM) Yes Valve protection: Heating and Cooling: Cooling blocked: Dimensions: Yes Yes, automatically Change Over on the CO terminal Yes, with jumper 85mm*85mm*25mm Warranty SALUS Controls warrants that this product (HTR230) will be free from any defect in materials or workmanship, and shall perform in accordance with its specification, for a period of five years from the date of installation. SALUS Controls sole liability for breach of this warranty will be (at its option) to repair or replace the defective product. Customer Name: ...................................................................................................................................................... Customer Address: ................................................................................................................................................. ............................................................................................................................................................................................ ....................................................................................... Post Code: ........................................................................... Tel No: .................................................................... Email: ....................................................................................... Engineers Company: .......................................................................................................................................... Tel No: ...................................................................... Email: .................................................................................... Instalation Date: .................................................................................................................................................... Engineers Name: ................................................................................................................................................... Engineers Signature: ........................................................................................................................................... 6. Protection Function 7. Control Patterns 5. Thermostat Functions NSB (Night SetBack) Function NSB Mode depends on the NSB wired connection. 0V = NSB OFF 230V= NSB ON The NSB signal is activated every 1 second. When the signal is received the setpoint temperature will be set at ±2°C or ±4°C. Heating and Cooling Selection The Heating/Cooling function is determined by the CO terminal connection. CO 0V= Heat mode CO 230V= Cool mode Cooling Blocked function Cooling Enabled: Set the jumper on ON . The thermostat will run in normal cooling mode. That means that it will open/close the actuators when necessary. The LED will be BLUE when the cooling function is running. Cooling Disabled: Set the jumper on OFF . The actuator will be closed and the LED will be off. Heat cut off at high/low temperature: When room temperature is over 36°C or under 4°C, all heating/cooling outputs will be turned off. Short cycle protection: When Cooling Mode is enabled the minimum interval between Relay ON/OFF is 3 minutes. Valve Protection: Set the jumper on ‘ON’ to disable the function or on ‘OFF’ to enable it. Turn on the valve for 5 minutes every week to prevent any damage to the valve. Sensor Malfunction: If the temperature sensor or temperature sensor compensation is open the LED will flash BLUE/RED alternatively. If CO terminal is connected and the Heating Mode is ON, the PWM function will be activated. If CO terminal is disconnected and the Cooling Mode is ON the ON/OFF control output will be activated. Rating max: 0,5 A
Similar Manuals in the Thermostat Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Honeywell Home T3 Pro |
Thermostat #SL3SO9 |
24 | 574 | 98 | 20-04-2026 | view all manuals | |
Mi-Heat TH213 |
Thermostat #4961I9 |
9 | 742 | 119 | 13-03-2026 | view all manuals | |
Hitecsa pGD1 |
pGD1 (Thermostat ePDF User Guide, #PK5S5H) |
16 | 20 | 4 | 29-05-2026 | view all manuals | |
Emerson EE542-1Z |
Thermostat #GZ5FJ3 |
24 | 0.37 Mb | 917 | 147 | 08-03-2026 | view all manuals |
Hunter F42213 |
F42213 Owner's manual - OR56O1 |
18 | 580 | 87 | 16-03-2026 | view all manuals | |
DeDietrich AD254 |
AD254 (Thermostat ePDF Manual, #FZ6GMT) |
14 | 192 | 33 | 27-06-2026 | view all manuals |