Sammode L10 MAXWELL SUB-ZERO MAINTAINED 184190 Manuals

1 pdf manual(s) Sammode L10 MAXWELL SUB-ZERO MAINTAINED 184190 for free download (Document Types: Installation & maintenance)

Sammode L10 MAXWELL SUB-ZERO MAINTAINED 184190 Installation & maintenance [PDF] (2 pages)

  • Identifier: id-1932752
  • Brand: Sammode
  • Device: L10 MAXWELL SUB-ZERO MAINTAINED 184190 Lighting Equipment
  • Type: PDF
  • Key Aspects: Information on Regular Maintenance, Step-by-Step Assembly Procedures, Model Variations and Compatibility
  • UPD Date: 12.06.2026
  • Source File: 2355238.pdf
  • Pages: 2
  • Description: Product documentation for the Sammode L10 MAXWELL SUB-ZERO MAINTAINED 184190.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Clevertronics Clever-test The Clevertronics Clever-test Lifelight (LLIFEM-PRO-SA-CT) can be programmed to perform 90 minute discharge tests at 6-month intervals. A manual test is initiated by pressing the test switch 3 times within a 5s period (immediate discharge test). A 24 hour delayed test (to allow batteries to fully charge before a test) can be initiated by pressing the test switch and hold for 10 seconds (i.e., until LED Test Switch indicator flashes rapidly). Refer Clever-test Operation Guide for more information. Once the test has been completed, maintenance personnel then view the Status Indicator of each fitting to determine a pass or failure: SOLID GREEN (not flashing) NORMAL – The luminaire is in a normal state charging and awaiting next discharge test. SLOW YELLOW FLASH (2s Yellow, 2s Off) TESTING – The luminaire is currently performing a test. VERY SLOW YELLOW & Green (4s Yellow, 1s Green) RECENTLY PASSED – The luminaire has previously tested and passed. This indication remains for 5 days after the completion of the test and then changes to SOLID Green to indicate a normal state. FAST YELLOW & Green FLASH (0.5s Yellow, 0.5s Green) FAILED LAST TEST – The luminaire has previously tested and failed to remain illuminated for the required duration. This indication will remain until the required maintenance work has been completed and the luminaire passes a subsequent discharge test. Zoneworks and DATA Monitored Options Lifelights with part numbers LLIFEM-PRO-SA-ZW, LLIFEM-PRO-SA-DATA are fitted with Zoneworks communications modules (nodes).These fittings are monitored using either Powerline Carrier Technology that utilising the power cable to provide data communication or a dedicated data cable to/from data routers installed on a dedicated data trunk connected to a central Server (can also be connected via Ethernet/Internet/Fibre). Zoneworks software on the server is used to monitor, coordinate testing and collate test data from each Lifelight. Zoneworks Lifelights can be commissioned by a single push of the test switch, or scanning of the supplied barcode. The LED Test Switch indicator provides a multifunction indication of the status of the Lifelight during testing and normal operation: State LED Operation Commissioned LED on Solid (Green) Un-commissioned LED flashes at 0.5Hz (0.5s Green, 0.5s Yellow) Emergency Light Test In Progress LED flashes at 3s On (Yellow) & 0.5s Off In the case of the DATA version a 2-way “figure 8” cable and terminal block facilitates the connection to the DATA network via a multi-drop bus (daisy chain connection). For further information of installation of a Zoneworks LW system, please refer to the Zoneworks Users Guide and Commissioning Guide (incl. DATA version) DALI EM Option Lifelights with part numbers LLIFEM-PRO-SA-DALI are fitted with DALI modules (nodes) that facilitate connection and integration to 3rd Party Lighting Control Systems. Before installing the LLIFE-PRO-DALI please confirm that the Lighting Control System has the capability to monitor DALI Emergency Luminaires. The LLIFE-PRO-DALI will be addressed and configured into the control system by the Lighting Control System Commissioning Technicians and not Clevertronics. State LED Operation Commissioned/ Un-commissioned LED on Solid (Green) Emergency Light Test in progress LED flashes at 1s On (Yellow) & 1s Off “IDENTIFY COMMAND” Fitting goes into emergency mode for 10 seconds A 2-way “figure 8” cable and terminal block facilitates the connection to the DALI network OR a 5/6way “structured wiring system” lead and plug facilitating the power and DALI connection. DALI connections are marked as Da Da. MAXWELL SUB-ZERO REMOTE MAINTAINED Installation & Maintenance Supplement Models: Testing Options: xx= MAXWELL SUB-ZERO MAINTAINED 184190 CT Clevertest ZW Zoneworks DATA Zoneworks DATA DALI DALI Spare Parts: LLIFEM-PRO-SASAMEMIPRM-xx-FIT 1530230 Battery, 3.3 Volt 5Ah Li-ion LLIFEM-PRO-SA-CKIT13V300C PCA: Lifelight Control-SA 300mA CT10142Lx Important: It is illegal for anyone, except for a licensed electrician to install or maintain this product. Before installation, ensure that the electricity supply has been switched off and isolated. Installation must be carried out in accordance with the relevant Australian and International Standards. Sammode Lighting Australia Pty Ltd 15 Industrial Avenue WACOL QLD 4076 Phone: 61 (0) 7 3335 3504 Fax: 61 (0) 7 3335 3522 Designed in Australia to comply with the requirements of AS2293.3: 2005, AS/NZS CISPR15: 2011 SAMMODE