Sanyo 18KLS52 Manuals
2 pdf manual(s) Sanyo 18KLS52 for free download (Document Types: Specification sheet, Submittal sheet)
Sanyo 18KLS52 Specification sheet [PDF] (3 pages)
- Identifier: id-314790
- Brand: Sanyo
- Device: 18KLS52 Air Conditioner
- Type: PDF
- Key Aspects: Environmental Factors and Restrictions, Additional Modules and Accessories Guide, Critical Operational Precautions
- UPD Date: 28.07.2026
- Source File: 279250.pdf
- Pages: 3
- Description: User reference guide for the Sanyo 18KLS52.
Click to expand and read text
-1- SANYO AIR CONDITIONING PRODUCTS DUCTLESS SPLIT SYSTEM AIR CONDITIONERS SPECIFICATIONS - SECTION 15700 Covers Sanyo System Models > 09KS51, 09KLS51, 12KS51, 12KLS51, 18KS52, 18KLS52, (See plans for specified model(s) & details) DUCTLESS SPLIT SYSTEM AIR CONDITIONERS - WALL MOUNT TYPE 1) GENERAL SPECIFICATIONS Furnish & install a Sanyo manufactured Ductless, Split System Air Conditioner(s), consisting of an indoor, high wall mounted evaporator/blower section & matching outdoor condensing section. System(s) shall bear the ARI label showing that the system(s) is ARI 210 or 240 & 270 Certified. Systems shall be listed by CSA International and bear the C-CSA US label. Matching systems shall meet or exceed the minimum, Federally mandated Seasonal Energy Efficiency Rating (SEER) of 10 as certified by the ARI testing programs. System(s) indoor & outdoor units will operate at sound levels equal to or below specified system(s) (see plans). Installation & Owners Manuals shall be provided with each system. Matching indoor & outdoor sections shall be connected by deoxidized, annealed refrigerant copper tubing, type “L”, cleaned & capped. All systems shall have flared refrigeration connections on both indoor & outdoor sections. Size & insulate tubing according to manufacturer’s specifications. System(s) indoor & outdoor sections shall be completely factory assembled & wired, with a pre- charge of refrigerant. A single power source shall provide voltage to both the outdoor & indoor units. Electrical wire & connections to outdoor section, and between indoor & outdoor section(s), shall be sized, installed & grounded by the installer in conformance with the National Electrical Code (N.E.C.), local codes, as well as, manufacturer’s instructions. System(s) shall be equipped with a microprocessor control system, utilizing an infrared remote controller with LCD display that provides access to all system functions, and transmits programs to the indoor microprocessor every 5 minutes. Infrared remote controller shall be capable of operating system mounted up to 26’ from the indoor section, according to manufacturer’s recommendations & instructions. System(s) shall have the capability of continuous operation in the case of a lost or damaged remote controller, utilizing a factory installed, integral manual switch in conjunction with the system microprocessor. 1A) System Infrared Remote Controller Functions will include: system mode selection, programmable temperature control, 24hour programmable timer, one (1) hour off timer, automatic three (3) speed indoor fan speed control, constant fan speed selection, night setback mode, automatic sweep/flap control, multiple system control using a single controller. 1B) System Features will include: Sanyo high efficiency, rotary compressor, cap tube refrigerant control, indoor coil freeze protection, built-in auto restart after power failure, short cycle time
Sanyo 18KLS52 Submittal sheet [PDF] (3 pages)
- Identifier: id-314837
- Brand: Sanyo
- Device: 18KLS52 Air Conditioner
- Type: PDF
- Key Aspects: Warranty and Service Information, Step-by-Step Assembly Procedures, Information on Regular Maintenance
- UPD Date: 29.04.2026
- Source File: 279302.pdf
- Pages: 3
- Description: Product usage manual for the Sanyo 18KLS52.
Click to expand and read text
AIRCONDITIONING PRODUCTS SUBMITTAL SHEET SYSTEM INDOOR/OUTDOOR 18KS52 KS1852/C1852 WALL MOUNTED AIR CONDITIONER GENERAL DATA(AT 230V) POWER V/PH/HZ 230/208 /1/ 60 Circuit Ampacity, Min. (A) 15 Fuse size, Max. (A) 15 COMPRESSOR Rotary-Hermetic No. used 1 R.L. Amps - L.R. Amps (A) 7.8/8.4-43 Crankcase Heater OUTDOOR FAN TYPE Propeller Dia. (in.) - No. used 16-17/32 - 1 Type Drive - No. speeds Direct - 1 No. Poles - RPM (High) 6 - 830 No. Motors - W 1 - 50 CFM (High) 1,390 F.L. Amps. (A) 0.49/0.46 OUTDOOR COIL - TYPE Aluminum Fin & Copper Pipe Fin Type - Pipe Type Slit Plate - Inner Riffled Rows - F.P.I. 2 - 24 Face Area (sq.ft.) 5.2 Tube Size (in.) 3/8 INDOOR FAN - TYPE Cross-flow Dia. & Length (in.) - No. used 3-15/32 & 29-3/8-1 No. speeds 3 & Auto No. Poles -RPM (High) 4-1,300 No. Motors - W 1 - 30 CFM (HI/MED/LOW) 390/345/315 F.L. Amps (A) 0.25/0.23 INDOOR COIL - TYPE Alminum Fin & Copper Pipe Fin Type - Pipe type Slit Plate - Inner Riffled Rows - F.P.I. 2 - 18 Face Area (sq. ft.) 2.64 Tube Size (mm) 7 Drain Connection Size (in.) 23/32 REFRIGERANT R22 Lbs. - R22 (O.D. Unit) 3.77 Control Capillary Tube Connection Flare Line Length, Max (ft.) 65 Lift difference, Max (ft.) 23 Line Size - in. O.D. Discharge 1/4 Line Size - in. O.D. Suction 5/8 DIMENSIONS (in.) H x W x D Indoor Unit -Uncrated 11-7/32 x 39-3/16 x 7-23/32 -Crated 10-7/8 x 42-1/8 x 14-9/32 Outdoor Unit -Uncrated 24-19/32 x 34-21/32 x 12-19/32 -Crated 27-15/16 x 40-9/16 x 16-3/16 WEIGHT INDOOR OUTDOOR Net (lbs.) 26.5 104 Shipping (lbs.) 33.0 112 Shipping Volume(cu.ft.) 3.78 10.6 SS-18KS52-3 PERFORMANCE DATA @ ARI STANDARD CONDITIONS (230V/208) COOLING Total Capacity(BTU/H) 17,000 / 16,500 Sensible Capacity (BTU/H) 12,200 / 11,950 Latent Capacity (BTU/H) 4,800 / 4,550 SEER 10.4 / 10.4 Dehumidification (Pints/H) 4.4 / 4.3 Amps (A) 7.8 / 8.4 Power Inputs (W) 1720 / 1670 Outdoor Sound Rating (bels) 7.8 FEATURE Controls Microprocessor Remote Controller LCD Wireless type Temperature Control IC Thermostat Timer Program Timer / 1 hour OFF Night Setback Built-In Air Louver (Horizontal) Manual (Vertical) Auto Power Failure Automatic Restart Built-In OPTION Refrigerant Line Set AP2507BH (20 ft) AP2510BH (30 ft) AP2515BH (50 ft) Fresh Air Intake N/A Central Remote ON-OFF Control Available Airduct Extension N/A Condensate Drain Pump Available Non-Removable Remo-con Bracket Available Air Clean Filter Available Outdoor unit Mounting Bracket Available OPERATING RANGE Cooling Indoor Air Outdoor Air Intake Temp. Intake Temp. Maximum 95 F DB/71 F WB 115 F DB Minimum 67 F DB/57 F WB 67 F DB CERTIFICATION 18KS52
Sanyo 18KLS52: Air Conditioner Category Related Instructions
SERVICE MANUAL Wall Mounted Type DC Inverter SUPER MATCH AS50S2SF2FA-2 Model No. This service information is designed for experienced repair technicians only and is not designed for use by the general public. It does not contain warnings or Product operation manual for the Haier AS50S2SF2FA-2 Inverter. It outlines the setup and operation, system setup, product handling, software installation.
V2.0 - 03132019 Portable Air Conditioner Owner’s Manual For more information on other great EdgeStar products on the web, go to https://www.edgestar.com To use the EdgeStar self-diagnostic tool, go to https://support.edgestar.com PAC10013CBL / PAC10013HBL User and installation guide for the Koldfront PAC10013CBL Air Conditioner. The guide explains operation and application scenarios, technical guidelines, testing procedures, detailing setup.
AIR COOLER, HEATER, HUMIDIFIER, IONIZER & FAN ВОЗДУХООХЛАДИТЕЛЬ, ОБОГРЕВАТЕЛЬ, УВЛАЖНИТЕЛЬ ВОЗДУХА, ИОНИЗАТОР И ВЕНТИЛЯТОР 5 B 1 ВОЗДУХООХЛАДИТЕЛЬ ОБОГРЕВАТЕЛЬ ИО Product usage manual for the Vitesse Home VS-868 Air Conditioner. This guide includes hardware instructions, operating modes, operational safety, troubleshooting tips.