Schako ERK-SO Manuals

1 pdf manual(s) Schako ERK-SO for free download (Document Types: Technical documentation manual)

Schako ERK-SO Technical documentation manual Thumbnail

Schako ERK-SO Technical documentation manual [PDF] (43 pages)

  • Identifier: id-1346331
  • Brand: Schako
  • Device: Schako ERK-SO Fire and Smoke Dampers
  • Type: Technical documentation manual, PDF
  • Key Aspects: Unpacking and Inspection Guidelines, Component Overview and Descriptions, Product Performance Metrics
  • UPD Date: 01.08.2026
  • Source File: 1381426.pdf
  • Pages: 43
  • Description: Device maintenance guide for the Schako ERK-SO.
Pages Preview:
  • Schako ERK-SO Technical documentation manual preview - page 2
  • Schako ERK-SO Technical documentation manual preview - page 3
  • Schako ERK-SO Technical documentation manual preview - page 4
  • Schako ERK-SO Technical documentation manual preview - page 5
  • Schako ERK-SO Technical documentation manual preview - page 6
  • Schako ERK-SO Technical documentation manual preview - page 7
  • Schako ERK-SO Technical documentation manual preview - page 8
  • Schako ERK-SO Technical documentation manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
SCHAKO | Ferdinand Schad KG Phone +49 (0) 7463-980-0 Steigstraße 25-27 Fax +49 (0) 7463-980-200 D-78600 Kolbingen www.SCHAKO.de | [email protected] USABILITY CERTIFICATES • Performance Reliability Certificate 0761 – CPR – 0506 • Declaration of Performance DoP-ERK-SO-2016-07-01 CLASSIFICATION AND STANDARDS • Classification according to EN 13501-4 is EI 90 (vedw, how i↔o) S 1000 C10000 MA multi, depending on the mounting situation • Product standard EN 12101-8 • Test standards EN 1366-2 and EN 1366-10 PERFORMANCE DATA • For ventilating smoke in smoke extraction systems and for providing the necessary sup- ply air within the smoke extraction installa- tion • For use in solid walls, ceilings and smoke ex- traction lines • For automatic (AA) or manual (MA) triggering SPECIAL FEATURES • Thermally insulated actuator housing • The installation position does not depend on the air flow direction or the position of the damper blade axle • Reversible OPEN/CLOSED actuator with 24 V AC/DC or 230 V AC supply voltage • Optional actuator with Powerline SLC bus technology possible. In conjunction with additional communication devices it is possible to retrieve further data, for example indication of end position, keep- ing timeframe (<60 s) or torque monitoring. ERK-SO Smoke extraction damper TECHNICAL DOCUMENTATION with installation, mounting and operating instructions

Similar Manuals in the Fire and Smoke Dampers Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
75F Smart Damper

#WW1JKT: Smart Damper Control Unit Installation & operation instructions

3 247 62 07-04-2026 view all manuals
LUCOMA DRK

LUCOMA DRK User Manual (Installation, operation and maintenance instructions), @VUL9H1

2 1155 174 14-05-2026 view all manuals
Schako BSK-EN

PDF Manual (@ITM2W9), Schako BSK-EN Fire and Smoke Dampers (28-04-2026)

21 315 51 28-04-2026 view all manuals
HVC Airtechnic NCA 100 Series

User Guide: HVC Airtechnic NCA 100 Series (99UOM6, Upd.29-04-2026)

2 1316 211 29-04-2026 view all manuals
Trox Technik EK-EU

PDF Guide (@2S5K3V), Trox Technik EK-EU Fire and Smoke Dampers (11-03-2026)

36 855 163 11-03-2026 view all manuals
Mandik FDMD

Mandik FDMD Manual (Installation instructions manual), @5K13J6

20 1026 247 29-05-2026 view all manuals