Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS,
WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED.
FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
WARNING! Ensure Health and Safety, local authority and general workshop practice
regulations are adhered to when using tools and equipment.
DO NOT use gauge if damaged.
Maintain gauge in good and clean condition for best performance.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the work area.
DO NOT use the gauge for any purpose other than for which it is designed.
DO NOT get gauge wet or use in damp or wet locations, or areas where there is
condensation. Keep gauge clean and dry using a dry cotton cloth only.
DO NOT dip or submerge the gauge in any type of liquid.
DO NOT expose gauge to bright sunlight or dust.
DO NOT disassemble gauge. The gauge must be checked by qualified service personnel only.
DO NOT apply any voltage to the gauge i.e. with an electric marker pen.
The gauge is a precision instrument, treat with care, avoid using force and do not subject to
knocks or shocks.
Use gauge in reasonably constant temperature conditions of approximately 20°C.
When not in use, turn off and store gauge in a safe, dry, childproof location.
1.
SAFETY INSTRUCTIONS.
2.
INTRODUCTION & SPECIFICATION.
Model No: ..................................................................VS0565
Range: ............................................................. 0-25mm (0-1")
Resolution:...................................................0.01mm(0.0005")
Accuracy: ..................................................±0.02mm (±0.001")
Battery Type: .......................................................SR44 - 1.5V
Item Description
1
Depth measuring probe
2
LCD Display
3
mm/inch Button
4
Locking screw
5
Foot
6
Power “ON/OFF” button
7
Zero set button
8
Battery cover
fig.1
VS0565 ISSUE No:1 25/03/13
INSTRUCTIONS FOR:
DIGITAL TYRE DEPTH
GAUGE - PIN TIP
MODEL NO: VS0565
Hardened and tempered stainless steel gauge. 11mm high figures in LCD display for ease of
reading. Metric and Imperial calibration with conversion between the two. Zero setting control
allows for comparative measurement. Pin type tread-probe. Supplied with calibration certificate
and storage case.
Original Language Version
© Jack Sealey Limited
fig.1
3.
OPERATION.
4.
MAINTENANCE.
3.1.
ZERO SETTING.
Prior to operation, perform a zero setting. To do this place the gauge foot (fig1.5.) on a flat
surface. Press the probe (fig1.1.) down until it is level with the foot then press the ‘ZERO’
button (fig1.7.); the gauge has been set to zero when the LCD displays ‘0.00’. Note: After
zero setting, the gauge retains this setting until the ‘ZERO' button is pressed again or the
battery is removed.
3.2.
PRODUCT USAGE.
Switch on the gauge by pressing the ON/OFF button (fig.1.6.). Place the gauge foot across
the tyre tread with the probe tip over the tyre groove. Press the probe down until it stops
moving then read the display. The pressure exerted by the tip of the measuring probe must
be uniform and constant to ensure correct and stable readings. Do not press too hard or
incorrect results will be recorded.
4.1.
BATTERY INSTALLATION/REPLACEMENT (fig.2)
NOTE! The battery should last for one year of
continuous use. If the display is blank or the digits are
flashing the battery voltage is too low, replace the
battery with a new SR44 battery. If the digits do not
change when buttons are pressed or probe is moved,
remove the battery for 1 minute to reset the unit. The
battery should be removed if the gauge is not to be
used for a long period of time.
4.1.1. Remove battery cover by sliding backwards and lifting
off.
4.1.2. Remove exhausted battery and fit replacement with +ve
side uppermost. Place the battery into the recess and
press into place. Slide the cover back and click home.
4.1.3. Dispose of old battery in a safe and approved manner.
Do not burn.
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Do not incinerate battery as it may explode when exposed to fire.
Do not attempt to open battery.
Contact your local solid waste authority for recycling information.
Battery Removal.
See Section 4.1 for battery removal.
Dispose of batteries according to local authority guidelines.
Under the Waste Batteries and Accumulators Regulations 2009, Jack Sealey Ltd are required to inform potential
purchasers of products containing batteries (as defined within these regulations), that they are registered with
Valpak’s registered compliance scheme. Jack Sealey Ltd’s Batteries Producer Registration Number (BPRN) is
BPRN00705
01284 757500
01284 703534
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and
component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.
WARRANTY: Guarantee is 12 months from purchase date, proof of which will be required for any claim.
INFORMATION: For a copy of our catalogue and latest promotions call us on 01284 757525 and leave
your full name, address and postcode.
[email protected]
www.sealey.co.uk
Web
email
VS0565 ISSUE No:1 25/03/13
Original Language Version
© Jack Sealey Limited
Sole UK Distributor,
Sealey Group,
Kempson Way, Suffolk Business Park,
Bury St. Edmunds, Suffolk,IP32 7AR
fig.2
Pages Preview: