Instructions [PDF] (2 pages)
- Updated: 19.06.2026
Document Preview & Text Transcription
INSTRUCTIONS FOR:
MODEL: VS0563
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and
properly maintained, give you years of trouble free performance.
IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND
CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO
MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY.
WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when
using tools and equipment.
DO NOT use gauge if damaged.
Maintain gauge in good and clean condition for best performance.
Keep the work area clean, uncluttered and ensure there is adequate lighting.
Keep children and unauthorised persons away from the work area.
DO NOT use the gauge for any purpose other than for which it is designed.
DO NOT get gauge wet or use in damp or wet locations, or areas where there is condensation. Keep gauge clean and dry
using a dry cotton cloth only.
DO NOT dip or submerge the gauge in any type of liquid.
DO NOT expose gauge to bright sunlight or dust.
DO NOT dis-assemble gauge. The gauge must be checked by qualified service personnel only.
DO NOT apply any voltage to the gauge i.e. with an electric marker pen.
The gauge is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.
Use gauge in reasonably constant temperature conditions of approximately 20°C.
When not in use, turn off and store gauge in a safe, dry, childproof location.
1.
safety instructions
2.
INTRODUCTION & SPECIFICATION
Specification....................................................................................... Depth Gauge
Resolution......................................................................................0.01mm/0.0005”
Range................................................................................................ 0-10mm/0.04”
Accuracy.......................................................................................±0.01mm/0.0005”
Battery type.........................................................................................CR2032 (3V)
Operating temp....................................................................................... 0°C - 40°C
Storage temp....................................................................................... -10°C - 60°C
Figure 1
Item Description
1
Depth measuring probe
2
LCD Display
3
mm/inch Button
4
Locking screw
5
Base
6
Power “ON/OFF” button
7
Zero set button
8
Battery cover
9
Beam
10
Zero set bar
11
Battery
Calibrated and VOSA approved for use when MOT testing all classes of vehicle.
Hardened and tempered stainless steel gauge. 7mm High figures in LCD display
for ease of reading. Metric and Imperial calibration with conversion between the
two. Zero setting control allows for comparative measurement. Supplied with
zero set bar.
fig.1
DIGITAL tread depth gauge - VOSA APPROVED
VS0563 ISSUE No:2 20/01/09
all-guides
com
3.
OPERATION
4.
Maintenance
3.1
ZERO SETTING
Prior to operation, perform a zero setting. To do this place the gauge foot on the zero set bar (fig 1 item 10) and press the
probe down until it is level with the base then press the ‘ZERO’ button, the gauge has been set to zero when the LCD
displays ‘0.00’. Note: After zero setting, the gauge retains this setting until the ‘ZERO button is pressed again or battery is
removed.
3.2
PRODUCT USAGE
Switch on the gauge by pressing the ON/OFF button. Place the gauge foot across the tyre tread with the probe tip over the
tyre groove. Press the probe down until it stops moving then read the display. The pressure exerted by the tip of the
measuring probe must be uniform and constant to ensure correct and stable readings. Do not press too hard or incorrect
results will be recorded.
4.1
BATTERY INSTALLATION/REPLACEMENT
NOTE! The battery should last for one year of continuous use. If the display is blank or the digits are
flashing the battery voltage is too low, replace the battery with a new CR2032 power cell. If the
digits do not change when buttons are pressed or probe is moved, remove the battery for 1
minute to reset the unit. The battery should be removed if the gauge is not to be used for a long
period of time.
4.1.1
Remove battery cover (fig.2-A) by sliding backwards and lifting off.
4.1.2
Remove rubber spacer (fig.2-B) and exhausted battery (fig.2-C) and fit replacement with +ve side
uppermost. Place the rubber spacer on top of the battery and press it into the recess. Slide the
cover back into place.
4.1.3
Dispose of old battery in a safe and approved manner. Do not burn. If the display fails to alter
when the slide is moved, remove the battery, wait at least 1minute and then refit the battery.
4.2
CALIBRATION
Tyre Depth Gauge should be re-calibrated annually by Sealey Power Products.
Environmental Protection.
Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be
sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment.
When the product is no longer required, it must be disposed of in an environmentally protective way.
Do not incinerate battery as it may explode when exposed to fire.
Do not attempt to open battery.
Contact your local solid waste authority for recycling information.
fig.2
VS0563
VS0563 ISSUE No:2 20/01/09
01284 757500
01284 703534
Sole UK Distributor
Sealey Group,
Bury St. Edmunds, Suffolk.
NOTE: It is our policy to continually improve products and as such we reserve the right to alter data, specifications and
component parts without prior notice. IMPORTANT: No liability is accepted for incorrect use of this product.