Sealey POWER PRODUCTS SA206 Manuals

1 pdf manual(s) Sealey POWER PRODUCTS SA206 for free download (Document Types: Instructions)

Sealey POWER PRODUCTS SA206 Instructions Thumbnail

Sealey POWER PRODUCTS SA206 Instructions [PDF] (2 pages)

  • Identifier: id-2300443
  • Brand: Sealey
  • Device: Sealey POWER PRODUCTS SA206 Controller
  • Type: Instructions, PDF
  • Key Aspects: Step-by-Step Assembly Procedures, Standard Operating Procedures, Warranty and Service Information
  • UPD Date: 23.07.2026
  • Source File: 1987181.pdf
  • Pages: 2
  • Description: Comprehensive operating guide for the Sealey POWER PRODUCTS SA206.
Pages Preview:
  • Sealey POWER PRODUCTS SA206 Instructions preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
InstructIons for: AIr regulAtor, FIlter, luBrICAtor rANge Models: SA206, SA206Fr, SA206F, SA206l, SA206r, SA206FrAD, SA206FAD. thank you for purchasing a sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. 1. SAFetY INStruCtIoNS IMPORTANT: PleASe reAD tHeSe INStruCtIoNS CAreFullY. Note tHe SAFe oPerAtIoNAl reQuIreMeNtS, WArNINgS & CAutIoNS. uSe tHe ProDuCt CorreCtlY AND WItH CAre For tHe PurPoSe For WHICH It IS INteNDeD. FAIlure to Do So MAY CAuSe DAMAge AND/or PerSoNAl INJurY AND WIll INVAlIDAte tHe WArrANtY. PleASe KeeP INStruCtIoNS SAFe For Future uSe. � WArNINg! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered to when using this equipment. � WArNINg!� Disconnect the equipment from the air supply before changing accessories, servicing or performing any maintenance. � Keep the equipment clean and maintain it in good condition (use an authorised service agent). � replace or repair damaged parts. Use genuine parts only. Unauthorised parts may be dangerous and will invalidate the warranty. � WArNINg! Ensure that the correct air pressure is maintained and not exceeded. � Keep air hoses away from heat, oil and sharp edges. check hoses for wear before each use and ensure that all connections are secure. � Do Not direct air from the air hose at yourself, others or animals. � Drain the compressor air tank daily. Water in the air line will damage your equipment. � When work is complete ensure that the air supply is turned off. suitable for industrial workshop air supply set-ups where high volume applications are required. regulator assemblies feature locking control knob for pre-setting air pressure and large easy-to-read pressure gauge. filters available with manual or auto drain facility with female 1/8”BsP outlet. Lubricator includes oil/air mix control and sight glass. filter and lubricator are fitted with metal bowl cages for protection. sA206, sA206fr, sA206frAD and sA206r supplied with mounting bracket. 2. INtroDuCtIoN & SPeCIFICAtIoNS Filter/lubricator/regulator - SA206 Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar) Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar) Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .105cfm filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000 Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP Filter/regulator - SA206Fr, SA206FrAD Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar) Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar) Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . sA206frAD only regulator - SA206r Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar) Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar) Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .210cfm Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP Gauge . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/4”BsP Filter - SA206F, SA206FAD Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar) Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar) Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .140cfm filter . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25 micron Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP Auto drain . . . . . . . . . . . . . . . . . . . . . . . . . . . .sA206fAD only lubricator - SA206l Max. inlet pressure . . . . . . . . . . . . . . . . . . . . 150psi (10.3 bar) Max. outlet pressure . . . . . . . . . . . . . . . . . . . . 125psi (8.6 bar) Max. flow rate @ 100psi (6.9 bar) . . . . . . . . . . . . . . . .175cfm Lubricant . . . . . . . .sealey Air tool oil - Ato/500 or Ato/1000 Ports-Inlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP outlet . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 1/2”BsP WArNINg! Filter and lubricator bowls are manufactured from polycarbonate and must not be used at temperatures over 125°F (52°C) or for pressures over 218psi (15 bar). Polycarbonate can be damaged and may fail if exposed to certain solvents either internally or externally - strong alkalies, compressor oils containing aromatic hydrocarbons or fire retardant oils, or the fumes of any of these. Clean with warm water only. SA206 SA206Fr & SA206FrAD SA206F & SA206FAD SA206l SA206r sA206/206fr/206f/206L/206r/206fAD/206frAD Issue: 2 - 05/09/08

Similar Manuals in the Controller Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Measurement Computing USB-3103

USB-3103 (Controller ePDF Guide, #H72S5G)

24 1274 230 20-08-2026 view all manuals
Fairford Electronics QFE Series

Fairford Electronics QFE Series Manual (Manual ), @891QPD

194 1369 206 25-07-2026 view all manuals
NatComm DS3

User Manual: NatComm DS3 (B3S62K, Upd.27-05-2026)

28 343 69 27-05-2026 view all manuals
Flycolor Raptor390 Tower F3 FC

Flycolor Controller Operation & user’s manual (File: PDF, 10-04-2026)

2 199 46 10-04-2026 view all manuals
GEM 639 eSyStep

Controller #33291L

62 1262 228 08-03-2026 view all manuals
YASKAWA MOTOMAN-NX100

YASKAWA Controller Instruction manual (File: PDF, 22-04-2026)

47 1428 258 22-04-2026 view all manuals