Instructions manual [PDF] (15 pages)
- Updated: 09.07.2026
Document Preview & Text Transcription
TA090
PAINT
THICKNESS
GAUGE
Original Language Version
TA090 Issue No.1 25/10/12
© Jack Sealey Limited
all-guides
com
1. SAFETY INSTRUCTIONS
3. SOFTWARE INTRODUCTION
4. SOFTWARE INSTALLATION
5. INSTALL USB DRIVER
Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions
and properly maintained, give you years of trouble free performance.
IMPORTANT: PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL
REQUIREMENTS, WARNINGS & CAUTIONS. USE THE PRODUCT CORRECTLY AND WITH CARE FOR THE
PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL
INJURY AND WILL INVALIDATE THE WARRANTY. PLEASE KEEP INSTRUCTIONS SAFE FOR FUTURE USE.
1.1.
GENERAL SAFETY
WARNING! Ensure Health & Safety, local authority, and general workshop practice regulations are adhered
to when using this gauge in workshop or bodyshop environments.
Take extra care if the vehicle is jacked up or on a raised ramp/hoist.
Maintain correct balance and footing at all times. Ensure floor/road surface is not slippery and wear non-slip
shoes.
If the vehicle is parked on a road, observe normal pedestrian precautions before working in the road,
especially on the offside of the vehicle.
DO NOT use when you are tired, under the influence of alcohol, drugs or intoxicating medication.
For the professional bodyshop or valeting bay to accurately verify the thickness of paint and check for accident
damage. Uses magnetic induction to provide accurate and consistent readings to 0.1µm. Suitable for steel and
aluminium panels. Easy to calibrate with test plates and precision standards. USB Interface for
downloading data to PC. Powered by two 1.5V batteries (supplied).
The supplied software program allows the Thickness gauge to communicate with a Desktop or Notebook PC. The
software displays thickness data graphically and in list form. The software also provides statistical analysis data.
The data can be saved in text document form for exporting to spreadsheet programs.
PC Operating Systems Supported
Windows 2000, Windows XP, Windows Vista and Windows 7.
Minimum Hardware Required
● Desktop or NoteBook Personal Computer (PC) with 90MHz processor speed
● 32 MB RAM
● 7 MB hard disk space
● Display pixel resolution of 1024 x 768 with high color setting (16 bit minimum)
2. INTRODUCTION & SPECIFICATIONS
INSTRUCTIONS FOR:
Paint Thickness Gauge
MODEL No: TA090
Model ................................................................. TA090
Accuracy:.................................................................±3%
Minimum unit of thickness:...................................0.1µm
Range:............................................................0-1250µm
PC Compatibility:..........Windows 2000, XP, Win7, Vista
Install the supplied Windows PC Software by placing the supplied program disc in the PC CD-ROM drive. If the
installation program does not automatically open and provide on-screen prompts, double click the SETUP.EXE file
included on the program disc. Follow the on-screen prompts to complete the installation. Before running the
software please connect the gauge to the PC and install the USB Driver software as described in the next section.
Run the CP210xVCPInstaller.exe in the driver folder to finish the driver installation.
Original Language Version
TA090 Issue No.1 25/10/12
© Jack Sealey Limited
Original Language Version
TA090 Issue No.1 25/10/12
© Jack Sealey Limited
6. MAIN MENU
7. OPERATION
With the gauge connected to the PC, switch the gauge ON. With the software application
and driver installed, launch the supplied program by double clicking its icon. The screen to
the right will appear. If the CONNECT button is greyed, the gauge is now communicating
with the PC normally. If the CONNECT button is black, click on it to start communication. If
communication is not successful, ensure that the software driver is installed. The driver is
located on the supplied CD-ROM in the driver folder.
The buttons available on the Main Menu are shown on the right and listed below:
● CONNECT: If black, press it to initiate gauge-to-PC communications. If grey,
communication is already active.
● GROUP 1…4: Open one of the four data group x-y graphs .
● ALL_Grps: Opens all four Group graph windows at once.
● CurrentGrp: With the gauge connected to the PC, readings can be taken and shown
on an x-y graph.
● µm < - >mils: Toggle the unit of measurement for the data graphs.
● Exit: Close the program.
‘GROUP’ DATA GRAPHS
Collect data into one or more of the data groups on the gauge (refer to the gauge's user guide for details on the
GROUP function). After collecting data to a gauge group, click a GROUP button from the MAIN MENU to open an
x-y graph as shown in the diagram below. (Click the ALL_Grps buttons to open all four groups)
The MENU items at the top of the graph window are SAVE *.TXT, SAVE *.CSV, GRAPH, and INFO. The SAVE
items allow the data to be saved as a text file with a TXT or CSV extension for exporting to spreadsheet programs.
The GRAPH selection offers TREND or HISTOGRAM graph styles; a TREND graph is shown on the next page and
a HISTOGRAM above.
Pages Preview: