TP201 ISSUE NO:2 - 011209 Original Language Version Petrol is a highly flammable liquid and any spillage will evaporate to form a flammable, heavier than air vapour which is easily ignited. Common ignition sources include, but are not limited to, smoking and lit matches, welding and cutting equipment, heaters, all types of electrical equipment unless specifically designed as suitable for use in flammable atmosphere. Even low voltage inspection lamps, if damaged, can ignite petrol vapour Please take time to read the following safety information before commencing work with the TP201. 4 Use the drainer only for its intended purpose. 4 Familiarise yourself with the applications, limitations, and potential hazards of this product. 4 Use original Sealey spare parts only. Unauthorised parts may be dangerous and will invalidate the warranty. 4 We recommend that the TP201 is used outdoors or in a well ventilated area, and well away from pits or other openings in the ground where vapour can collect. 4 Disconnect the vehicle's battery before draining fuel. 4 Keep a foam or dry powder fire extinguisher nearby. 4 Ensure containers cannot easily be knocked over during filling. 4 Ensure the drainer tank is large enough to hold the contents of the fuel tank you are draining. 4 Ensure space required for use and maintenance of the drainer is adequate, free from unrelated materials and has good lighting. 4 Attach earth lead to the fuel container using the crocodile clip supplied. 4 Always use the earth bonding straps by connecting one to the vehicle chassis, away from any potential fuel vapour, and the other to a suitable earthing point. 4 Remove all combustible materials from the work area. 4 Use only containers rated for the fuel being drained. Ensure that the container mouth is as narrow as possible while still allowing insertion of the drain hose. 4 HSE guidance recommends use of metal containers with secure caps for holding drained fuel. 4 Mark fuel containers with hazard labels to show their contents. 4 Keep any fuel containers in a well ventilated, lockable store, preferably outside the working area. 4 Soak up any spills immediately using absorbent granules or similar material. 4 Keep children and unauthorised persons away from the working area, especially when the drainer is in operation. Keep the work area childproof by using padlocks and master switches. 4 Maintain the drainer in top condition. Keep it clean for best and safest performance. 4 Follow the same precautions when transferring fuel from the drainer back into the vehicle or into any other container. 8 DO NOT use this drainer for anything other than its intended purpose. The TP201 is only to be used for pumping fuel from diesel or petrol vehicles. 8 DO NOT work on a fuel tank or remove a sender unit before draining the fuel. 8 DO NOT use an open flame or smoke anywhere near the drainer or around stored fuel. 8 DO NOT drain fuel into open-topped containers such as buckets and watering cans. DO NOT drain fuel into dedicated workshop oil drain equipment. 8 DO NOT drain fuel into plastic containers except for quantities less than 10 litres. 8 DO NOT allow work which can produce a source of ignition, such as welding, electrical or other hot work, to be carried out while draining petrol. 8 DO NOT drain fuel over, or close to, a pit or drain because of the risk of flammable vapour accumulation. 8 DO NOT use any electrical equipment on or near the vehicle while fuel draining is in progress. This includes the use of inspection lights, cordless/mobile phones or pagers. 8 DO NOT store drained or contaminated fuel in the workplace unless it is to be returned to the vehicle immediately. 8 DO NOT add drained fuel to the waste oil tank. 8 DO NOT wear clothing on which petrol has been spilt - stop work and change into uncontaminated clothing before continuing to work. 8 DO NOT use the drainer if the pump is damaged in any way. 8 DO NOT leave the unit running unattended. 8 DO NOT use whilst under the influence of drugs, alcohol or other intoxicating medication, or if you are fatigued. 8 DO NOT use the drainer for a job it was not designed to do. 8 DO NOT tamper with the safety valve fitted to the tank. 1. SAFETY INSTRUCTIONS Instructions For: FUEL TANK DRAINER 90ltr STAINLESS STEEL MODEL NO: TP201 Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance. IMPORTANT BEFORE USING THIS PRODUCT, PLEASE READ THE INSTRUCTIONS CAREFULLY. MAKE CAREFUL NOTE OF SAFETY INSTRUCTIONS, WARNINGS AND CAUTIONS. THIS PRODUCT SHOULD ONLY BE USED FOR ITS INTENDED PURPOSE. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. RETAIN THESE INSTRUCTIONS FOR FUTURE USE. Users/Businesses should perform their own hazard risk assessment based on their specific environment and following the guidelines laid out above.

Sealey TP201: Service Equipment Category Related Instructions

Dolphin Wave
Maytronics Dolphin Wave
13.04.2026 84 pages

8151564 by Dolphin Service Kit User Instructions..........................p. 1 Mode d’emploi..............................p. 11 Istruzioni per l’uso.......................p. 21 Manual del usuario......................p. 31 Bedienungsanleitung.............. Product reference manual for the Maytronics Dolphin Wave Service Equipment. This documentation explains configuration and maintenance procedures, basic operation, device operation tips.

EG 0332
CLAS EG 0332
06.08.2026 16 pages

clas-equipements.com PERCEUSE A COLONNE Ømax 25mm 750W 220V + ETAU DRILL Ømax 25mm 750W 220V + VICE EG 0332 Comprehensive instruction manual for the CLAS EG 0332 Service Equipment. The document includes error codes, system configuration, detailing setup.

MVA 6825
Mityvac MVA 6825
08.04.2026 2 pages

Section- MV22 Page - 1 Form 822721 MARCH - 04 Fluid Refill Kit MVA 6825 A quick and simple procedure that refills your master cylinder reservoir and/or hydraulic clutch reservoir with new fluid when bleeding a hydraulic system. Fluid feeder adapter fits most p Device setup manual for the Mityvac MVA 6825 Service Equipment. This reference includes replacement parts, network configuration, hardware components, error handling.

600 215
Prolux 600 215
14.05.2026 47 pages

Originalbetriebsanleitung Original operating instruction Vario-Radklammer 2000 kg / 3500 kg Vario wheel clamp 2000 kg / 3500 kg Code no.: 600 215 / 600 245 p. 18-21 Italiano p. 22-24 Český Deutsch S. 2-5 DE Español p. 14-17 ES p. 10-13 Français FR English Device operation guide for the Prolux 600 215 Service Equipment. It details safety instructions and safety, technical specifications, installation procedures.