Sealey VS0567 Manuals

1 pdf manual(s) Sealey VS0567 for free download (Document Types: Instructions)

Sealey VS0567 Instructions Main Page Preview

Instructions [PDF] (2 pages)

  • Updated: 29.03.2026

Document Preview & Text Transcription

IMPORTANT PLEASE READ THESE INSTRUCTIONS CAREFULLY. NOTE THE SAFE OPERATIONAL REQUIREMENTS, WARNINGS, AND CAUTIONS. USE THIS PRODUCT CORRECTLY AND WITH CARE, FOR THE PURPOSE FOR WHICH IT IS INTENDED. FAILURE TO DO SO MAY CAUSE DAMAGE AND/OR PERSONAL INJURY AND WILL INVALIDATE THE WARRANTY. Thank you for purchasing a Sealey product. Manufactured to a high standard this product will, if used according to these instructions and properly maintained, give you years of trouble free performance.  WARNING! Ensure Health and Safety, local authority and general workshop practice regulations are adhered to when using tools and equipment.  DO NOT use gauge if damaged.  Maintain gauge in good and clean condition for best performance.  Keep the work area clean, uncluttered and ensure there is adequate lighting.  Keep children and unauthorised persons away from the work area.  DO NOT use the gauge for any purpose other than for which it is designed.  DO NOT get gauge wet or use in damp or wet locations, or areas where there is condensation. Keep gauge clean and dry using a dry cotton cloth only.  DO NOT dip or submerge the gauge in any type of liquid.  DO NOT expose gauge to bright sunlight or dust.  DO NOT disassemble gauge. The gauge must be checked by qualified service personnel only.  DO NOT apply any voltage to the gauge i.e. with an electric marker pen.  The gauge is a precision instrument, treat with care, avoid using force and do not subject to knocks or shocks.  Use gauge in reasonably constant temperature conditions of approximately 20°C.  When not in use, turn off and store gauge in a safe, dry, childproof location. 1. SAFETY INSTRUCTIONS. 2. INTRODUCTION & SPECIFICATION. Model No: . . . . . . . . . . . . . VS0567 Range: . . . . . . . . . 0-300mm (0-12") Resolution: . . . . . .0.01mm(0.0005") Accuracy: . . . . . ±0.02mm (±0.001") Battery Type: . . . . . . . .SR44 - 1.5V VS0567 ISSUE No:1 27/03/13 INSTRUCTIoNS foR: DIGITAL BRAKE DISC AND DRUM CALLIPER 300MM/12" MoDEL No: VS0567 Original Language Version © Jack Sealey Limited KEY 1:. . . . . . . . . . . . . . . . .Internal Jaws 2:. . . . . . . . . . . . . . . . External Jaws 3:. . . . . . . . . . . . . . . . on/off Button 4:. . . . . . . . . . . . . . . . . . Zero Button 5:. . . . . . . . . . . . . . . . . . Hold Button 6:. . . . . . . . . . . Unit Selector Button 7:. . . . . . . . . . . . . . . . . . Lock Screw 8:. . . . . . . . . . . . . . . . Battery Cover Measures disc thickness (external) and small/medium sized drums (internal). Hardened and tempered stainless steel gauge. 11mm High figures in LCD display for ease of reading. Metric or Imperial read-out with ‘Hold’ function. Zero setting control allows for comparative measurement. Supplied with calibration certificate and storage case. fig.1 VS0567 3. OPERATION. 4. MAINTENANCE. 3.1. ZERO SETTING. Prior to operation, perform a zero setting. To do this close the jaws (fig1.1.) then press the ‘ZERo’ button (fig1.4.); the gauge has been set to zero when the LCD displays ‘0.00’. Note: After zero setting, the gauge retains this setting until the ‘ZERo' button is pressed again or the battery is removed. 3.2. PRODUCT USAGE. 3.2.1. Ensure all surfaces are clean before measuring. 3.2.2. Switch on the gauge by pressing the on/off button (fig.1.3.) and set units using unit selector button (fig1.6). 3.2.3. for disc measurement: open the external jaws to clear the lip and close onto the disc surface. The reading may be saved by pressing the Hold Button (fig1.5), allowing withdrawal over the lip. A second press returns to the current reading. 3.2.4. for drum measurement: extend the internal jaws until they meet the inner surface of the drum. 3.2.5. The use of excessive force will lead to innacurate measurement and damage to the gauge. 4.1. BATTERY INSTALLATION/REPLACEMENT (fig.2) NoTE! The battery should last for one year of continuous use. If the display is blank or the digits are flashing the battery voltage is too low, replace the battery with a new SR44 battery. If the digits do not change when buttons are pressed or probe is moved, remove the battery for 1 minute to reset the unit. The battery should be removed if the gauge is not to be used for a long period of time. 4.1.1. Remove battery cover by sliding backwards and lifting off. 4.1.2. Remove exhausted battery and fit replacement with +ve side uppermost. Place the battery into the recess and press into place. Slide the cover back and click home. 4.1.3. Dispose of old battery in a safe and approved manner. Do not burn. Environmental Protection. Recycle unwanted materials instead of disposing of them as waste. All tools, accessories and packaging should be sorted, taken to a recycle centre and disposed of in a manner which is compatible with the environment. When the product is no longer required, it must be disposed of in an environmentally protective way. Do not incinerate battery as it may explode when exposed to fire. Do not attempt to open battery. Contact your local solid waste authority for recycling information. fig.2