SENDOT FluoMini Pro Manuals

3 pdf manual(s) SENDOT FluoMini Pro for free download (Document Types: Operation & user’s manual)

Available Documents for FluoMini Pro:

SENDOT FluoMini Pro Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (24 pages)

  • Brand: SENDOT
  • Model: FluoMini Pro
  • Format: PDF
  • Key Aspects: Operational Mode Explanations, System Connectivity and Wiring Basics, Recommended Spare Parts List
  • Updated: 05.06.2026
  • Source File: 1991656.pdf
  • Pages: 24
  • Description: User instruction booklet for the SENDOT FluoMini Pro.

Document Preview & Text Transcription

User manual System information FluoMini Pro type: 300 Firmware: version 200501 Software: version 2.21 Baudrate: 19200 www.sendot.nl FluoMini Pro Optical O2|T Sensor 2 Contents 1. General .......................................................................................................................... 4 1.1. Product ....................................................................................................................... 4 1.1.1. Scope of delivery .................................................................................................... 4 1.1.2. Technical specifications .......................................................................................... 4 1.2. Important user instructions ......................................................................................... 6 1.3. Warranty ..................................................................................................................... 6 1.4. Transport, storage and disposal ................................................................................. 6 2. Installation ...................................................................................................................... 7 2.1. Unpacking and setup .................................................................................................. 7 2.2. Type probe ................................................................................................................. 7 2.3. Connections ............................................................................................................... 7 2.3.1. Handheld sensor ..................................................................................................... 7 2.3.2. Digital sensor .......................................................................................................... 7 2.3.3. Analog sensor ......................................................................................................... 8 2.4. Display and buttons .................................................................................................... 8 3. Measuring with the FluoMini Pro Optical O2|T Sensor .................................................. 10 3.1. Measurement principle ............................................................................................. 10 3.2. Ending the standby mode ......................................................................................... 10 3.2.1. Handheld sensor ................................................................................................... 10 3.2.2. Digital sensor ........................................................................................................ 11 3.2.3. Analog sensor ....................................................................................................... 11 3.3. Measurements .......................................................................................................... 11 3.3.1. Single measurement ............................................................................................. 11 3.3.2. Continuous measurements ................................................................................... 11 3.4. Logger and transmitter function ................................................................................ 12 4. Settings ........................................................................................................................ 13 4.1. Main menu ............................................................................................................... 13 4.2. General settings ....................................................................................................... 13 4.2.1. Date/Time ............................................................................................................. 13 4.2.2. Power management .............................................................................................. 14 4.2.3. Save data ............................................................................................................. 14 4.2.4. Decimal separator ................................................................................................. 14 4.3. Logger settings (handheld/digital) ............................................................................. 15 4.3.1. Logger On/Off ....................................................................................................... 15 4.3.2. Interval time .......................................................................................................... 16 4.3.3. Memory ................................................................................................................. 16 3 4.4. Transmitter settings (analog) .................................................................................... 17 4.4.1. Transmitter On/Off ................................................................................................ 17 4.4.2. Interval time .......................................................................................................... 17 4.4.3. A-out Test ............................................................................................................. 18 4.4.4. Memory ................................................................................................................. 18 4.5. Sensor settings ......................................................................................................... 19 4.5.1. Calibrate ............................................................................................................... 19 4.5.2. Enter Cal. data ...................................................................................................... 21 4.5.3. Measurement settings ........................................................................................... 21 4.6. System info .............................................................................................................. 22 5. Troubleshooting ........................................................................................................... 23
SENDOT FluoMini Pro Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (23 pages)

  • Brand: SENDOT
  • Model: FluoMini Pro
  • Format: PDF
  • Key Aspects: Model Variations and Compatibility, Hardware Setup Instructions, Component Overview and Descriptions
  • Updated: 15.06.2026
  • Source File: 1991655.pdf
  • Pages: 23
  • Description: Service and user manual for the SENDOT FluoMini Pro.

Document Preview & Text Transcription

FluoMini Pro Optical Chlorophyll Fluorescence (CF) Sensor System information FluoMini Pro type: 102 Firmware: version 200501 Software: version 2.21 Baudrate: 19200 User manual www.sendot.nl 1 Contents 1. General .......................................................................................................................... 3 1.1. Product ....................................................................................................................... 3 1.1.1. Scope of delivery .................................................................................................... 3 1.1.2. Technical specifications .......................................................................................... 3 1.2. Important user instructions ......................................................................................... 4 1.3. Warranty ..................................................................................................................... 4 1.4. Transport, storage and disposal ................................................................................. 5 2. Installation ...................................................................................................................... 6 2.1. Unpacking and setup .................................................................................................. 6 2.2. Type probe ................................................................................................................. 6 2.3. Connections ............................................................................................................... 6 2.3.1. Handheld sensor ..................................................................................................... 6 2.3.2. Digital sensor .......................................................................................................... 6 2.3.3. Analog sensor ......................................................................................................... 7 2.4. Display and buttons .................................................................................................... 7 3. Measuring with the FluoMini Pro Optical CF Sensor ...................................................... 9 3.1. Measurement principle ............................................................................................... 9 3.2. Ending the standby mode ........................................................................................... 9 3.2.1. Handheld sensor ..................................................................................................... 9 3.2.2. Digital sensor .......................................................................................................... 9 3.2.3. Analog sensor ....................................................................................................... 10 3.3. Measurement ........................................................................................................... 10 3.3.1. Single measurement ............................................................................................. 10 3.3.2. Continuous measurements ................................................................................... 10 3.4. Logger and transmitter function ................................................................................ 11 4. Settings ........................................................................................................................ 12 4.1. Main menu ............................................................................................................... 12 4.2. General settings ....................................................................................................... 12 4.2.1. Date/Time ............................................................................................................. 12 4.2.2. Power management .............................................................................................. 13 4.2.3. Save data ............................................................................................................. 13 4.2.4. Decimal separator ................................................................................................. 13 4.3. Logger settings (handheld/digital) ............................................................................. 14 4.3.1. Logger On/Off ....................................................................................................... 14 4.3.2. Interval time .......................................................................................................... 15 4.3.3. Memory ................................................................................................................. 15 2 4.4. Transmitter settings (analog) .................................................................................... 16 4.4.1. Transmitter On/Off ................................................................................................ 16 4.4.2. Interval time .......................................................................................................... 16 4.4.3. A-out Test ............................................................................................................. 17 4.4.4. Memory ................................................................................................................. 17 4.5. Sensor settings ......................................................................................................... 18 4.5.1. Calibrate ............................................................................................................... 18 4.5.2. Enter Cal. data ...................................................................................................... 19 4.5.3. Measurement settings ........................................................................................... 20 4.6. System info .............................................................................................................. 20 5. Troubleshooting ........................................................................................................... 21 3 1. General 1.1. Product Product FluoMini Pro Optical Chlorophyll Fluorescence (CF) Sensor Version 1 Software 2.21 Firmware 200501 1.1.1. Scope of delivery • FluoMini Pro Optical CF Sensor (handheld, analog or digital) • Fiber with stainless steel probe or leaf clip • USB cable (1.0 m) • Analog cable (1.0 m, for analog sensor only) • Digital cable (1.0 m, for digital sensor only) • CF calibration cap 1.1.2. Technical specifications Specifications Values Measurement range 0 – 10 mg/g or 0 – 35000 counts Temperature range + 5 to + 45°C Accuracy 0 – 1 mg/g* ± 0.1 mg/g Accuracy 1 – 5 mg/g* ± 0.2 mg/g Accuracy 5 – 10 mg/g* ± 0.3 mg/g Drift / Stability (operating frequency 0.1 Hz) ≤ 0.1 % per month Sample time ≤ 2 sec Calibration 1 point (using the CF calibration cap)
SENDOT FluoMini Pro Operation & user’s manual Main Page Preview

Operation & user’s manual [PDF] (20 pages)

  • Brand: SENDOT
  • Model: FluoMini Pro
  • Format: PDF
  • Key Aspects: Manufacturer Contact and Support Data, Performance Optimization Tips, Cleaning and Sanitization Methods
  • Updated: 31.03.2026
  • Source File: 2404988.pdf
  • Pages: 20
  • Description: Product documentation for the SENDOT FluoMini Pro.

Document Preview & Text Transcription

User manual System information FluoMini Pro type: 400 Firmware: version 191010 Software: version 2.17 Baudrate: 19200 www.sendot.nl FluoMini Pro Optical pH Sensor 2 Contents 1. General .......................................................................................................................... 4 1.1. Product ....................................................................................................................... 4 1.1.1. Scope of delivery .................................................................................................... 4 1.1.2. Technical specifications .......................................................................................... 4 1.2. Important user instructions ......................................................................................... 5 1.3. Warranty ..................................................................................................................... 6 1.4. Transport, storage and disposal ................................................................................. 6 2. Installation ...................................................................................................................... 7 2.1. Unpacking and setup .................................................................................................. 7 2.2. Type probe ................................................................................................................. 7 2.3. Connections ............................................................................................................... 7 2.3.1. Handheld sensor ..................................................................................................... 7 2.3.2. Digital sensor .......................................................................................................... 7 2.3.3. Analog sensor ......................................................................................................... 8 2.4. Display and buttons .................................................................................................... 9 3. Measuring with the FluoMini Pro Optical pH Sensor .................................................... 10 3.1. Measurement principle ............................................................................................. 10 3.2. Ending the standby mode ......................................................................................... 10 3.2.1. Handheld sensor ................................................................................................... 10 3.2.2. Digital sensor ........................................................................................................ 10 3.2.3. Analog sensor ....................................................................................................... 10 3.3. Measurements .......................................................................................................... 11 3.3.1. Single measurement ............................................................................................. 11 3.3.2. Continuous measurements ................................................................................... 11 3.4. Logger and transmitter function ................................................................................ 11 4. Settings ........................................................................................................................ 12 4.1. Main menu ............................................................................................................... 12 4.2. General settings ....................................................................................................... 12 4.2.1. Date/Time ............................................................................................................. 12 4.2.2. Power management .............................................................................................. 13 4.2.3. Save data ............................................................................................................. 13 4.2.4. Decimal separator ................................................................................................. 13 4.3. Logger settings (handheld/digital) ............................................................................. 13 4.3.1. Logger On/Off ....................................................................................................... 14 4.3.2. Interval time .......................................................................................................... 14 4.3.3. Memory ................................................................................................................. 15 3 4.4. Transmitter settings (analog) .................................................................................... 15 4.4.1. Transmitter On/Off ................................................................................................ 16 4.4.2. Interval time .......................................................................................................... 16 4.4.3. A-out Test ............................................................................................................. 16 4.4.4. Memory ................................................................................................................. 17 4.5. Sensor settings ......................................................................................................... 17 4.5.1. Calibrate ............................................................................................................... 17 4.5.2. Enter Cal. data ...................................................................................................... 18 4.5.3. Measurement setting ............................................................................................ 19 4.6. System info .............................................................................................................. 19 5. Troubleshooting ........................................................................................................... 20 4 1. General 1.1. Product Product FluoMini Pro Optical pH Sensor Version 1 Software 2.17 Firmware 191010 1.1.1. Scope of delivery • FluoMini Pro Optical pH Sensor (handheld, analog or digital) • Fiber with probe equipped with sensitive coating • USB cable • Analog cable (for analog sensor only) • Digital cable (for digital sensor only) • Pre-drill • Probe support • USB stick with user manual and FluoMini Software Suite • Quick Guide • Installation sheet (for digital and analog sensors only) 1.1.2. Technical specifications Specifications Values pH range 3.0 – 8.5 Temperature range + 5 to + 45 °C Accuracy pH 3.5 – 4.0 ± 0.2 pH Accuracy pH 4.0 – 7.0 ± 0.1 pH Accuracy pH 7.0 – 8.5 ± 0.2 pH Resolution pH 0.01 pH