ShoreTel ST100DA Manuals

1 pdf manual(s) ShoreTel ST100DA for free download (Document Types: Quick install manual)

ShoreTel ST100DA Quick install manual Thumbnail

ShoreTel ST100DA Quick install manual [PDF] (2 pages)

  • Identifier: id-1668496
  • Brand: ShoreTel
  • Device: ShoreTel ST100DA Switch
  • Type: Quick install manual, PDF
  • Key Aspects: Troubleshooting Information, Hardware Setup Instructions, Hardware Verification Checklists
  • UPD Date: 25.04.2026
  • Source File: 1650230.pdf
  • Pages: 2
  • Description: Owner’s guide for the ShoreTel ST100DA.
Pages Preview:
  • ShoreTel ST100DA Quick install manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Introduction About the ST100DA The ST100DA Voice Switches connect enterprise telephone extensions through an internal IP network, or to any central office (CO) analog trunk line. The switch provides connectivity through: • Two RJ-45 10/100/1000 Mbps LAN connectors • One DB-9 (female), RS-232C maintenance port (115,200 bps, 8 bits, no parity, 1 stop bit, no handshake) for serial communications • One audio input port (3.5 mm stereo) for connecting to a music-on-hold source • One audio output port (3.5 mm stereo) for connecting to a corporate paging system or night bell. This port is grounded. ShoreTel provides an optional paging adapter to provide a balanced output as well as a contact closure ideal for overhead paging systems. Refer to the ShoreTel Paging Adapter Quick Install Guide for information about the Paging Adapter. • USB port for logging/troublesooting • RJ-48C Telco port(s) for connecting the switch to a telephone company line. • RJ-21X port for connections to analog devices The ShoreTel ST100DA Voice Switch Package Contains: • ShoreTel 100DA Voice Switch • Power cord • Stick-on feet for surface installation • Mounting Ears – attachable installation brackets • Cable retainer for the Telco cable (metal bracket with a Velcro Strap) Installation and Servicing Connections Mounting the ShoreTel Voice Switch on a Flat Surface If you plan to mount the switch on a flat surface, first attach the provided rubber feet to the bottom corners of the device. You can stack up to three switches in a surface installation. Installing the ST100DA in a 19-inch Rack The ST100DA is placed in a 19-inch rack only by mounting a ShoreTel Dual Tray into the rack, then installing the voice switch into the Tray. Refer to the Quick Install Guide for the ShoreTel Dual Tray for Tray installation instructions and information on using the Tray. Connecting Trunk and Telephone Lines Use the provided cable retainer to connect the voice switch to the telephone company’s punch-down block or patch panel. Optional Connections After connecting the voice switch to the LAN, you can make optional connections, including input from a music-on-hold source or output to an internal paging system. Powering on the ShoreTel Voice Switch After connecting the switch to the network, power on the device by connecting it to an AC power source. 1. Plug an AC surge protector (not provided) into a grounded AC power source. 2. Plug one end of the provided power cord into the receptacle on the back of the switch, then plug the other end into the AC surge protector. The power LED flashes momentarily, and remains lit. • If the LED is not lit, make sure the power cord is plugged into the switch and the power source. • If the LED continues flashing, there is an internal error. Unplug the switch to power it off, then power it back on. Refer to the “Configuring Switches” chapter in the ShoreTel Administration Guide for information on flash patterns, or contact the ShoreTel Support Services at http://www.shoretel.com. The LAN ports auto-sense the network transport rate. When the network connection is established, the network LED indicates a transport rate of 10/100/1000 Mbps, and whether the switch is receiving and transmitting data. Use an RJ-45 Ethernet cable to connect one or both of the LAN ports to the network subnet. While both ports can detect and respond to link status, the switch uses only one LAN port at a time. German: Einen Erdungsleiter anschließen Um den elektrischen Sicherheitsanforderungen für eine korrekte Erdung nachzukommen, müssen Sie einen permanenten Erdungsschutz zwischen dem ShoreGear-Gerät und der Erde des Kabelsystems installieren. 1. Schließen Sie ein Erdungskabel (Nr. 14 AWG oder größer) an die Schraube an der Rückseite des Geräts an, die sich rechts neben dem Produktetikett befindet. 2. Schließen Sie das andere Ende des Erdungskabels an die Erde des Kabelsystems an. VORSICHT: Schließen Sie immer zuerst den permanenten Erdungsschutz an, bevor Sie ver- suchen, das Gerät an ein LAN-Segment und Telekommunikationsleitungen anzuschließen. Connecting the ShoreTel Voice Switch to the Network Once the ST100DA Voice Switch is secured to a rack or surface-mounted, you can connect it to the data network. Power LED USB port Audio input port 10/100/1000 Mbps Ethernet ports RS-232C maintenance port Status LED Audio output port RJ-21X port RJ-48C Telco port Installation Equipment To install the switch, you need the following equipment: • AC surge protector for the power connection • RJ-45 cable for connecting the switch to the local area network • Music-on-hold source with a standard mini-headphone Y-adapter (optional) • Permanent earthing connector for grounding the device • RJ-21 telephone cable (female connector on end that is connected to the ShoreTel voice switch) for analog port connections • RJ-21 to RJ-11 patch panel for connecting telephones and trunk lines • #1 Phillips screwdriver Installation Location Requirements To ensure optimum operating conditions for the ST100DA voice switch, verify the operating environment is adequately ventilated, free of gas or airborne particles, and isolated from electrical noise. 1. Use a #1 Phillips screwdriver to remove the two screws on either side of the RJ-21X port, then place the retainer on the port and re-attach the screws. 2. Plug the Telco cable into the port, then pull the Velcro strap tightly around the cable connector and fasten it. 3. Connect the other end of the Telco cable to the punch-down block or patch panel. CAUTION: To reduce risk of fire, use only No. 26 AWG or larger (e.g. 24 AWG) UL Listed or CSA certified telecommunication line cord. VORSICHT: Um das Brandrisiko zu verringern, verwenden Sie nur Telekommunikationslei- tungen Nr. 26 AWG oder größer (z.B. 24 AWG) mit UL- oder CSA-Zulassung For detailed information on switch port and trunk configuration, see the “Configuring Switches” and “Configuring Trunks” sections in the ShoreTel Administration Guide. 1. Connect a music-on-hold source (CD player or other audio source) to the audio input port. 2. Connect your site’s paging system to the audio output port. German: Das ShoreTel Voice-Schaltgerät auf einer ebenen Oberfläche montieren Wenn Sie planen, das Gerät auf einer ebenen Oberfläche zu montieren, befestigen Sie zunächst die mitgelieferten Gummifüße an den unteren Ecken des Geräts. (Bei einer Oberflächeninstallation können Sie bis zu drei Schaltgeräte übereinander stapeln.) Attaching an Earthing Connector To meet electrical safety requirements for proper grounding, you must connect a permanent earthing protector between the ShoreTel voice switch and the wiring system ground. 1. Connect a ground wire (#14 AWG wire or larger) to the screw on the back of the unit and to the right of the product label. 2. Connect the other end of the ground wire to the wiring system ground. CAUTION: Always connect the permanent earthing connector before attempting to connect the switch to a LAN segment and telecommunication lines. Servicing Procedures WARNING: The ST100DA contains no internal field serviceable parts. Return the equipment to ShoreTel for any required service procedures. CAUTION: Internal fuses should be serviced only by qualified ShoreTel personnel. If internal fuses are blown and require replacement, return the ST100DA to ShoreTel for service. WARTUNGSVERFAHREN ACHTUNG: Der ST100DA enthält keine internen Teile, die vor Ort gewartet werden können. Senden Sie das Gerät an ShoreTel, falls Wartungsarbeiten erforderlich sein sollten. VORSICHT: Interne Sicherungen dürfen nur von qualifizierten ShoreTel-Mitarbeitern gewartet werden. Wenn interne Sicherungen ausgetauscht werden müssen, senden Sie den ST100DA zur Wartung an ShoreTel.” Installing the ST100DA on a Wall Mount The ST100DA is placed on a wall mount by attaching the wall mount to the wall, and then attaching the appliance to the mount. Refer to the ShoreTel Dual Tray: Wall Mount Kit Quick Install Guide for more information.

Similar Manuals in the Switch Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
ADDER AdderLink AV series

Switch #G79379

2 0.32 Mb 475 86 25-03-2026 view all manuals
TRENDnet TU-S9

TU-S9 Operation & user’s manual - 4L1D53

16 2.47 Mb 407 78 21-05-2026 view all manuals
ConnectGear GENIE 4

GENIE 4 (Switch ePDF Guide, #H226Z9)

1 1.45 Mb 1157 186 27-07-2026 view all manuals
IKEA tradfri

Security Sensors #MEDA3P

24 1399 322 05-09-2026 view all manuals
ATEN VM1616T

VM1616T Specification - BCXER5

4 0.97 Mb 772 116 11-06-2026 view all manuals
Stahl 8549/1

Stahl Switch Operating instructions manual (File: PDF, 15-03-2026)

49 218 42 15-03-2026 view all manuals