Siemens DELTA 5TC1 01 Manuals

1 pdf manual(s) Siemens DELTA 5TC1 01 for free download (Document Types: Operating and mounting instructions manual)

Siemens DELTA 5TC1 01 Operating and mounting instructions manual Thumbnail

Siemens DELTA 5TC1 01 Operating and mounting instructions manual [PDF] (6 pages)

  • Identifier: id-2383747
  • Brand: Siemens
  • Device: Siemens DELTA 5TC1 01 Kitchen Appliances
  • Type: Operating and mounting instructions manual, PDF
  • Key Aspects: System Limitations and Considerations, Common Issue Diagnostic Flows, Warranty and Service Information
  • UPD Date: 04.04.2026
  • Source File: 2421044.pdf
  • Pages: 6
  • Description: Device operation guide for the Siemens DELTA 5TC1 01.
Pages Preview:
  • Siemens DELTA 5TC1 01 Operating and mounting instructions manual preview - page 2
  • Siemens DELTA 5TC1 01 Operating and mounting instructions manual preview - page 3
  • Siemens DELTA 5TC1 01 Operating and mounting instructions manual preview - page 4
  • Siemens DELTA 5TC1 01 Operating and mounting instructions manual preview - page 5
  • Siemens DELTA 5TC1 01 Operating and mounting instructions manual preview - page 6
Document Preview & Text Transcription (Main Page)
Click to expand and read text
254136.41.04 DS04 1(6) Bitte Rückseite beachten! Please see overleaf! Produkt- und Funktionsbeschreibung Product and Applications Description Bitte lesen Sie die Bedien- und Montageanleitung vor der Inbetriebnahme vollständig durch. Die SCHUKO-Steckdose mit integriertem Fehlerstromschutz 5TC1 01. ist ein Unterputzgerät, welches aus einem UP-Geräte- einsatz und einer designspezifischen Abdeckplatte besteht. Sie ist zum Einbau in handelsübliche UP-Gerätedosen (Ø 60 mm, für Schraubenbefestigung) geeignet. Das Funktionsprinzip der SCHUKO-Steckdose mit integriertem Fehlerstromschutz entspricht dem des Fehlerstrom-Schutz- schalters (FI-Schutzschalter). Es bezieht sich auf alle Geräte und Leitungen, welche an die SCHUKO-Steckdose mit integrier- tem Fehlerstromschutz angeschlossen sind. Die Elektroinstalla- tion bis zur Steckdose ist jedoch nicht FI-geschützt. An die FI-geschützten Verbindungsleiter können weitere, normale SCHUKO-Steckdosen angeschlossen werden, welche dann auch dem Fehlerstromschutz unterliegen. Please ensure that you have thoroughly read and under- stood the operating and mounting instructions prior to commissioning. The SCHUKO socket outlet and integrated 5TC1 01. RCCB is a flush-mounting device comprising a flush-mounting device insert and a design-specific cover plate. It is suitable for installation in conventional flush-mounting device boxes (Ø 60 mm, for screw fixing). The principle of operation of SCHUKO socket outlets with integrated residual current protection corresponds to that of residual current operated circuit breakers (RCCBs). It applies to all devices and lines connected to the SCHUKO socket outlet with integrated RCCB. However, the electrical installation up to the socket outlet is not RCCB protected. Any additional normal SCHUKO socket outlets connected to the interconnecting conductor will also be RCCB protected. Bedienung Operation Funktionsprüfung: Nach der Montage muss die Funktion der FI-SCHUKO- Steckdose überprüft werden (Bild A-1). Bei anliegender Span- nung und eingeschaltetem Schalter (I) muss die Testtaste (T) gedrückt werden. Der Schalter muss auslösen (Stellung 0). Nach erfolgreichem Test ist der Schalter wieder in Stellung (I) zu schieben. Prüfen Sie zusätzlich mit einem geeigneten Prüfgerät, ob die Steckdose wirklich spannungsfrei geschaltet ist. Der Test ist während des Betriebs halbjährlich zu wiederho- len. Es dürfen keine FI-SCHUKO-Steckdosen in Betrieb genommen werden, welche die Funktionsprüfung nicht bestanden haben. Betrieb: Ein-/Ausschalten: Stellungsanzeige: Testtaste T: Löst die FI-SCHUKO-Steckdose im Betrieb bei angeschlossenen Elektrogeräten aus, so sind diese defekt und müssen von einer Elektrofachkraft überprüft werden. Einschaltschiebegriff 0-I Testtaste T halbjährlich drücken. FI-SCHUKO-Steckdose muss auslösen. Function testing: Once installed, it is essential to test the RCCB protected SCHUKO socket outlet to ensure that it is fully functional (Fig. A-1). The test pushbutton (T) must be pressed with the voltage applied and the switch (I) activated. The switch must trip (position 0). Once the test has been carried out successfully, the switch must be returned to position (I). A suitable inspection and test device should also be used to check that the socket outlet really is off circuit. This test must be repeated during operation at 6 month intervals. Never use RCCB protected SCHUKO socket outlets that have not passed this function test. Operation: On/Off switching: Position indication: Test pushbutton T: If the RCCB protected SCHUKO socket outlet trips during runtime when electrical devices are con- nected, these devices are defective and must be inspected by a fully qualified electrical technician. Sliding switch-on handle 0-I Press the test pushbutton T every 6 months. The RCCB protected SCHUKO socket outlet must trip. Anschlussbeispiel Connection Example Bilder A-2: TN-S-System: L Außenleiter N Neutralleiter PE Schutzleiter A-3: TN-C-System: L Außenleiter PEN Neutralleiter mit Schutzfunktion A-4: TT-System: L Außenleiter N Neutralleiter PE Schutzleiter Figures A-2: TN-S system: L Phase conductor N Neutral conductor PU Protective conductor A-3: TN-C system: L Phase conductor PEN Neutral conductor with protective function A-4: TT system: L Phase conductor N Neutral conductor PU Protective conductor Technische Daten Technical Specifications Spannungsversorgung: • Bemessungsspannung: • Bemessungsstrom: • Bemessungsfehlerstrom: • Auslösecharakteristik: • Bemessungsfrequenz: • Bemessungsschaltvermögen: • Bemessungs-/Kurzschluss- strom: • Gesamtabschaltzeit bei 5x Bemessungsfehlerstom: • Lebensdauer - elektrisch: - mechanisch: • Erschütterungsfestigkeit: • Gebrauchslage: • Schutzgrad: • Gewicht: 230 V~ 16 A 30 mA Typ A 45 … 60 Hz 500 A 3000 A bei max. Vorsicherung 16 A gG oder 16 A Leitungsschutzschalter ≤ 30 ms 1000 Schaltzyklen 3000 Schaltzyklen 400 m/s², halbsinus, 4ms Puls beliebig IP21 (mit Abdeckplatte) 100 g Power supply: • Rated voltage: • Rated current: • Rated residual current: • Tripping characteristic: • Rated frequency: • Rated short-circuit capacity: • Rated/short-circuit current: • Total break time at 5x rated residual current: • Service life - electrical: - mechanical: • Vibration strength: • Mounting position: • Degree of protection: • Weight: 230 V AC 16 A 30 mA Type A 45 … 60 Hz 500 A 3000 A at max. backup fuse, 16 A gG or 16 A miniature circuit breakers ≤ 30 ms 1000 switching cycles 3000 switching cycles 400 m/s², half sinus, 4ms pulse as required IP21 (with cover plate) 100 g Prüfung der Schutzmaßnahme: Zusätzlich zur Funktionsprüfung ist die Wirksamkeit der Schutzmaßnahme entsprechend den geltenden Errich- tungsbestimmungen zu prüfen. Die höchstzulässigen Erdungs- widerstände betragen für den Schutz bei indirektem Berühren: Höchstzulässige Berührungsspan- nung Höchstzulässiger Erdungs- widerstand bei Bemes- sungsfehlerstrom von 30 mA 25 V 833 Ω 50 V 1666 Ω Checking the protective measure: In addition to function testing, the effectiveness of the protective measure should also be tested in accordance with the pertinent installation regulations. The highest permissible grounding resistances for protection against direct contact are as follows: Highest permissible touch voltage Highest permissible ground- ing resistance for rated residual current of 30 mA 25 V 833 Ω 50 V 1666 Ω A-1 A-2 A-3 A-4 DELTA SCHUKO-Steckdose mit inte- griertem Fehlerstromschutz 5TC1 01. Socket with integrated residual current circuit 230V~, 16A, 30mA Bedien- und Montageanleitung Operating and mounting instructions Stand: Juli 2009 As at: July 2009 254136.41.04 DS04

Similar Manuals in the Kitchen Appliances Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
IFM Electronic efector 500 PI00 A Series

efector 500 PI00 A Series (Kitchen Appliances ePDF Guide, #1K5HB9)

24 587 89 22-08-2026 view all manuals
Princess 01.183008.01.001

PDF User Guide (@IO66P8), Princess 01.183008.01.001 Kitchen Appliances (03-06-2026)

72 804 145 03-06-2026 view all manuals
Vintage Industries Cool-Tool VICT50-3

#9GR524: Cool-Tool VICT50-3 Kitchen Appliances Operation manual

40 1487 313 28-05-2026 view all manuals
Roxtec RS 150 OMD

#U6L2XF: RS 150 OMD Kitchen Appliances Installation instructions

4 1461 249 17-06-2026 view all manuals
TEFAL COMFORT

User Manual: TEFAL COMFORT (JO229E, Upd.24-03-2026)

72 2.93 Mb 764 176 24-03-2026 view all manuals
Braun MR 5500 BC

#61HB48: MR 5500 BC Blender Operation & user’s manual

46 3.75 Mb 197 50 13-08-2026 view all manuals