Siemens RDF400 Manuals

4 pdf manual(s) Siemens RDF400 for free download (Document Types: Documentation, Basic documentation, Manual )

Document Preview & Text Transcription

RDF300, RDF300.02 RDF340, RDF600 RDF300.02/VB RDF400.01, RDF600T Flush-mounted room thermostats for Fan coils, with LCD RDF300… / RDF340... / RDF400… / RDF600… Basic Documentation Edition 4.0 CE1P3076en 2020-02-21 Smart Infrastructure 2 / 46 Siemens RDF300… / RDF340... / RDF400… / RDF600… Basic Documentation CE1P3076en Smart Infrastructure Contents 2020-02-21 Table of contents 1 About this document ........................................................................... 3 1.1 Revision history ..................................................................................... 3 1.2 Reference documents ............................................................................ 3 1.3 Before you start ..................................................................................... 3 1.3.1 Copyright ............................................................................................... 3 1.3.2 Quality assurance .................................................................................. 3 1.3.3 Document use / request to the reader .................................................... 4 2 Summary .............................................................................................. 5 2.1 Brief description ..................................................................................... 5 2.2 Features ................................................................................................ 5 2.3 Type summary ....................................................................................... 6 2.4 Equipment combinations ........................................................................ 7 2.5 Accessories ........................................................................................... 8 3 Use ....................................................................................................... 8 4 Functions ............................................................................................. 9 4.1 Temperature control ............................................................................... 9 4.2 Operating modes ................................................................................. 10 4.3 Room temperature setpoints ................................................................ 11 4.4 Applications ......................................................................................... 12 4.5 Additional features ............................................................................... 15 4.6 Control sequences ............................................................................... 17 4.6.1 2-pipe fan coil unit................................................................................ 18 4.6.2 2-pipe fan coil unit with electrical heater ............................................... 19 4.6.3 4-pipe fan coil unit................................................................................ 21 4.7 Control outputs .................................................................................... 23 4.8 Fan control .......................................................................................... 24 4.9 Multifunctional input ............................................................................. 27 4.10 Auto Timer (RDF400… / RDF600T only) .............................................. 28 4.11 Error handling ...................................................................................... 30 4.12 Infrared remote control ......................................................................... 30 4.13 DIP switches ........................................................................................ 31 4.14 Control parameters .............................................................................. 31 5 Handling ............................................................................................. 34 5.1 Mounting and installation ..................................................................... 34 5.2 Operating Instructions .......................................................................... 35 5.3 Disposal .............................................................................................. 35 6 Engineering ........................................................................................ 36 6.1 Connection terminals ........................................................................... 36 6.2 Connection diagrams ........................................................................... 37 6.2.1 Water-based fan coil applications with RDF300... / RDF400... / RDF600… ........................................................................................... 37 6.2.2 Compressor-based applications with RDF300... / RDF400... / RDF600…38 6.2.3 Water-based fan coil applications with RDF340... ................................. 39 7 Mechanical design ............................................................................. 40 7.1 Dimensions.......................................................................................... 41 8 Technical data .................................................................................... 42 Index ............................................................................................................ 44 3 / 46 Siemens RDF300… / RDF340... / RDF400… / RDF600… Basic Documentation CE1P3076.en Smart Infrastructure 2020-02-21 1 About this document 1.1 Revision history Edition Date Changes Section Pages 4.0 2020-02-21 · Added RDF300.02/VB 1, 6 3.0 2014-10-15 · Update overcurrent protection from a fuse to a circuit breaker; · Update the notation for valves; · Update the warning for wiring and mounting; · Update the standards and directives for RoHS 2.0. 4.4 4.6 5.1 6.2 8 12 17 34 37 42 2.0 Oct 2012 Added RDF600… All All 1.1 28 Aug 2008 Left column in table 4.4 Applications 12 1.0 10 July 2008 First edition 1.2 Reference documents Ref. Document title Type of document Document No. N3076 Flush-mounted room temperature controllers with LCD Datasheet CE1N3076 B3076 Operating instructions CE1B3076... M3076 Mounting instructions RDF3... RDF400 CE1M3076 M3163 Mounting instructions RDF600… CE1M3163 1.3 Before you start 1.3.1 Copyright This document may be duplicated and distributed only with the express permission of Siemens, and may be passed only to authorized persons or companies with the required technical knowledge. 1.3.2 Quality assurance These documents have been prepared with great care: · The contents of all documents are checked at regular intervals · Any corrections necessary are included in subsequent versions · Documents are automatically amended as a consequence of modifications and corrections to the products described Please ensure that you are aware of the latest revision date of the documentation. If you find lack of clarity while using this document, or if you have any criticisms or suggestions, please contact the Product Manager in your nearest branch office. The addresses of the Siemens Regional Companies are available at www.buildingtechnologies.siemens.com. 4 / 46 Siemens RDF300… / RDF340... / RDF400… / RDF600… Basic Documentation CE1P3076.en Smart Infrastructure 2020-02-21 1.3.3 Document use / request to the reader Before using our products, it is important that you read the documents supplied with or ordered at the same time as the products (equipment, applications, tools, etc.) carefully and in full. We assume that persons using our products and documents are authorized and trained appropriately and have the technical knowledge required to use our products as intended. More information on the products and applications is available: · On the intranet (Siemens employees only) at https://workspace.sbt.siemens.com/content/00001123/default.aspx · From the Siemens branch office near you www.buildingtechnologies.siemens.com or from your system supplier · From the support team at headquarters [email protected] if there is no local point of contact Siemens assumes no liability to the extent allowed under the law for any losses resulting from a failure to comply with the aforementioned points or for the improper compliance of the same.
Siemens RDF400 Manual  Main Page Preview

Manual  [PDF] (14 pages)

  • Updated: 15.07.2026

Document Preview & Text Transcription

CE1N3076en 2018-12-27 Building Technologies s 3076 RDF300, RDF300.02, RDF340 RDF400.01 RDF600 RDF600T Flush-mounted room thermostats RDF300… RDF340 RDF400… RDF600... for 2-pipe, 2-pipe with el. heater and 4-pipe fan coil units for use with compressors in DX type equipment · RDF300 / RDF400 / RDF600/RDF600T: AC 230 V operating voltage, on/off or 3-position control outputs · RDF340…:AC 24 V, operating voltage, DC 0…10 V control outputs · Output for 3-speed or 1-speed fan · 2 multifunctional inputs for keycard contact, external sensor, etc. · Operating modes: Comfort, Economy and Protection · Automatic or manual fan speed control · Automatic or manual heating/cooling changeover · Adjustable commissioning and control parameters · Minimum and maximum setpoint limitation · User and parameter settings can be retained or restored with power loss Additional features · Backlit LCD (RDF300.02, RDF400.01, RDF600, RDF600T) · Infrared remote control receiver (RDF400.01, RDF600T) · Auto Timer mode with 8 programmable timers (RDF400.01, RDF600T) Type of mounting / suitable conduit boxes · RDF600... for round CEE box, with min 60 mm diameter, min 40 mm depth · RDF3… / RDF400... for recessed square box with 60.3 mm fixing centers 2/14 Siemens RDF300…/RDF340 / RDF400… / RDF600... Flush-mounted Room thermostats CE1N3076en Building Technologies 2018-12-27 Use To control the room temperature in individual rooms and zones that are: · Heated or cooled with 2-pipe fan coil units · Heated or cooled with 2-pipe fan coil units with electrical heater · Heated and cooled with 4-pipe fan coil units · Heated or cooled with compressor in DX type equipment · Heated or cooled with compressor in DX type equipment with electrical heater · Heated and cooled with compressor in DX type equipment The RDF300… / RDF400… / RDF600... control: · One 1- or 3-speed fan · One or 2 on/off valve actuators · One on/off valve actuator and one 1-stage electrical heater · One 3-position valve actuator · One 1-stage compressor in DX type equipment or one 1-stage compressor with electrical heater The RDF340… controls: · One 1- or 3-speed fan · One or 2 DC 0…10 V valve actuators · One DC 0…10 V valve actuator and one modulating electrical heater (DC 0…10 V) Used in systems with: · Heating or cooling mode · Automatic heating/cooling changeover · Manual heating/cooling changeover · Heating and cooling mode (e.g. 4-pipe system) Functions · Maintain room temperature via built-in temperature sensor or external room temperature / return air temperature sensor · Automatic or manual changeover between heating and cooling mode · Select applications via DIP switches · Select operating mode via the operating mode button on the thermostat · 1- or 3-speed fan control (automatic or manual) · Display current room temperature or setpoint in °C and/or °F · Minimum and maximum setpoint limitation · Key lock (automatic and manual) · 2 multifunctional inputs, freely selectable for: – Operating mode switchover contact (key card) – Automatic heating/cooling changeover sensor – External room temperature or return air temperature sensor – Dewpoint sensor – Electrical heater enable – Alarm input · Advanced fan control function, i.e. fan kick, fan start, selectable fan operation (enable, disable or depending on heating or cooling mode) · Purge function together with 2-port valve in a 2-pipe changeover system · Reminder to clean filters · Floor heating temperature limit · Reload factory settings for commissioning and control parameters · 7-day time program: 8 programmable timers to switch over between Comfort and Economy mode (RDF400.01 / RDF600T) · Backlit LCD (RDF300.02 / RDF400.01 / RDF600 / RDF600T) · Optional infrared remote control ( RDF400.01 / RDF600T) Applications 3/14 Siemens RDF300…/RDF340 / RDF400… / RDF600... Flush-mounted Room thermostats CE1N3076en Building Technologies 2018-12-27 Applications The thermostat supports the following applications, which can be configured by DIP switches on the inner side of the thermostat’s front. Depending on the type, on/off or modulating control outputs are available. Applications for fan coil systems Application and output signal, DIP switches, diagram · 2-pipe fan coil unit ON/OFF (heating or cooling) ON 1 2 RDF300... RDF400... RDF600... · 2-pipe fan coil unit ON/OFF (heating or cooling) with electrical heater ON 1 2 RDF300... RDF400... RDF600... · 2-pipe fan coil unit modulating, DC 0…10 V (heating or cooling) ON 1 2 RDF340 · 2-pipe fan coil unit modulating, DC 0…10 V (heating or cooling) with electrical heater ON 1 2 RDF340 3076D20 (B1) M1 V1 T B2 T T (B1) V1 M1 3171D21 T B2 E1 T (B1) T (B1) · 2-pipe fan coil unit modulating, 3-position (heating or cooling) ON 1 2 RDF300... RDF400... RDF600... · 4-pipe fan coil unit ON/OFF (heating and cooling) ON 1 2 RDF300... RDF400... RDF600... ON 1 2 RDF340 3076D20 (B1) M1 V1 T B2 T T (B1) T V2 V1 M1 3076D22 (B1) T (B1) V1 Heating or heating/cooling valve actuator M1 3-speed or single-speed fan V2 Cooling valve actuator B1 Return air temperature sensor or external room temperature sensor (optional) E1 Electrical heater B2 Changeover sensor (optional) 4/14 Siemens RDF300…/RDF340 / RDF400… / RDF600... Flush-mounted Room thermostats CE1N3076en Building Technologies 2018-12-27 Applications for Universal systems Application and output signal, DIP switches, diagram · Chilled / heated ceiling ON/OFF (heating or cooling) ON 1 2 RDF300... RDF400... RDF600... · Chilled / heated ceiling ON/OFF (heating or cooling) with electrical heater ON 1 2 RDF300... RDF400... RDF600... · Chilled / heated ceiling modulating, DC 0…10 V (heating or cooling) ON 1 2 RDF340 · Chilled / heated ceiling modulating, DC 0…10 V (heating or cooling) with electrical heater ON 1 2 RDF340 3191S11 N1 T B1 T B2 T D3 V1 3191S12 N1 T E1 B1 T B2 T D3 V1 · Chilled / heated ceiling modulating, 3-position (heating or cooling) ON 1 2 RDF300... RDF400... RDF600... · Chilled ceiling and radiator ON/OFF (heating and cooling) ON 1 2 RDF300... RDF400... RDF600... ON 1 2 RDF340 3191S11 N1 T B1 T B2 T D3 V1 3191S13 N1 T B1 T D3 V2 V1 V1 Heating or heating / cooling valve actuator B1 Return air temperature sensor or external room temperature sensor (optional) V2 Cooling valve actuator B2 Changeover sensor (optional) E1 Electrical heater D3 Dewpoint sensor

Document Preview & Text Transcription

CE1B3076.2en / 25 Feb 2010 Subject to change Siemens Building Technologies s Operating Instructions RDF400... RDF400... – the room thermostat that allows you to set the ideal room temperature. The thermostat provides Comfort, Energy Saving, and Protection mode and can operate in Auto timer mode using 8 programmable time schedules. The fan operates either in Auto mode or at a speed selected in Manual mode. You can either take advantage of the thermostat's factory settings or adjust it as needed. Display Protection mode Auto Timer mode Comfort mode Energy Saving mode Measured room temperature, setpoints and parameters Current time of day Actual room temperature Fault indicator * Condensation in the room * Cooling demand / mode Heating demand / mode Electrical heater active Automatic fan Low fan speed Medium fan speed High fan speed Buttons are locked Weekday 1…7 (1 = Monday / 7 = Sunday) Operation and settings Operating mode button  **  **  View and set Auto-Timer-Programm Protection mode / system ON Colder / Warmer Fan mode button – Automatic fan ( ) – Manual fan ( ) Set time of day and weekday Confirm settings * Needs to be configured by your HVAC installer ** Needs to be enabled via parameter P02 Change room temperature + / – Press + or – to increase or decrease the current room temperature setpoint for Comfort mode. The thermostat changes to Comfort . The setting range is 5...40 °C, unless limited by parameters P09 and P10. Adjust fan speed / fan mode Press the button until you reach the desired fan mode. In Auto mode, the thermostat automatically selects the fan speed based on set- point and actual room temperature. The fan continues to run at low speed (factory setting) after the room temperature reaches the setpoint . In manual mode, the fan always runs at the speed that you select: Low fan speed Medium fan speed High fan speed For a single-speed fan, you can change the mode between and . Change thermostat operating Press operating mode button to change the operating mode display. In protection mode, the plant stops operating. However, if the room temperature drops below 8 °C, heating is switched on to protect the room against frost. Your HVAC installer can change the frost protection limit and set a heat pro- tection limit as needed: Changes made by installer:  Frost protection: ........... ˚C Heat protection: ........... ˚C In Comfort mode, the thermostat maintains the room temperature on the set- point which can be readjusted using the + and – buttons. In Energy Saving mode, the room temperature is maintained at a lower or higher setpoint, thus saving energy and money. Adjust parameters P11 and P12 to change the preselected setpoints. The thermostat can be set to Energy Saving mode either by pressing the ope- rating mode button if enabled (P02 = 2), or via an external signal (switch) such as window contact, keycard or presence detector. In Auto timer mode, the thermostat automatically switches between Comfort and Energy Saving mode according to the time schedule. Change from heating to cooling mode / Changeover between cooling and heating is either automatic using a heating / cooling changeover sensor or a remote changeover switch, or manual by pressing the operating mode button . No changeover is possible if the thermostat is configured for cooling only or heating only, (see parameter P01). Display for automatic changeover or heating only / cooling only: Heating valve is open Cooling valve is open Display for manual changeover: Thermostat is in heating mode Thermostat is in cooling mode CE1B3076.2en / 25 Feb 2010 Subject to change Siemens Building Technologies Setting time of day and weekday + – 24h  12 h + – 1. Keep the button pressed until the time digits start to flash. Press + or – to set the time of day. If the current time is in 24-hour format and you wish to change to the 12-hour format, press + passing 23:59 or press – passing 00:00. Back to 24-hour format: same procedure with 11.59 PM. 2. Confirm the time of day by pressing and the weekday indicator starts to flash. 3. Press + or – to set the current weekday. 4. Confirm the current weekday by pressing . Set time schedules Ax + – + – + – To adjust the time schedule, keep the button pressed for 3 seconds to go to the timer setting mode. This mode is indicated by displaying Ax (x= auto timer 1...8) and the time flashing. For each timer, proceed as follows: 1. The and symbols are displayed. Press + or – to adjust the comfort mode start time and confirm by pressing . 2. The and symbols are displayed. Press + or – to adjust the comfort mode end time / energy saving start time and confirm by pressing . 3. Symbol will flash. Press + or – to select or deselect each day and advance to the next day. 4. Press to confirm the settings for the actual timer and advance to the next timer. The thermostat will leave the timer setting mode if no button is pressed within 20 seconds. All changes made after the last press of the button will not be saved. View the timer settings Press the button to sequentially review the 8 auto timers. Reload default timer settings + – / 1. Set the thermostat to protection mode . 2. Press + and – simultaneously for 3 seconds. Release and, within 2 seconds, press 2 times Days Thermostat is in Comfort mode Mo (1) – Fr (5) 6:30 – 8:30 (A1) 17:30 – 22:30 (A2) Sa (6) 8:00 – 23:00 (A3) Su (7) 8:00 – 22:30 (A4) Default settings – In the remaining time thermostat is in energy saving mode. – Timers A5…A8 are free, no default settings. Button lock Press operating mode button for 5 seconds to lock or unlock the buttons if manual button lock is configured (parameter P14 = 2). The thermostat automatically locks the buttons 30 seconds after the last adjustment if "Auto lock" is configured (P14 = 1). The key symbol indicates locked buttons. Reminder to clean filters and for external faults FIL * This message reminds you to clean your HVAC equipment filters. It is displayed after ………… “fan operating hours” and disappears when the thermostat is set to Protection ( ). * Needs to be configured by your HVAC installer Note: Energy saving mode The energy saving setpoints are factory-set to 15 °C for heating and 30 °C for cooling. Use parameters P11 and P12 to adjust the values. Important: You can set these setpoints to OFF; the thermostat then is inactive, i.e. no protective heating or cooling function.  Risk of frost! Commissioning You can adjust a number of control parameters to adapt the thermostat to your system and optimize control performance. You can do this during operation via the buttons on the thermostat. Control parameters Proceed as follows to change the most important control parameters: (Your HVAC installer can set additional parameters) + / – 1. Press the – and + buttons simultaneously at least 3 seconds. Release, and within 2 seconds, press + again for 3 seconds. "P01" is displayed. 2. Repeatedly press the + or – button to select the required parameter. P01 P02 P08 P14 + - + - - + 3171z99 End - + - P13 + - 3. Press + and – simultaneously. The current value of the selected parameter begins to flash, allowing you to change the value by repeatedly pressing + or –. 4. The next parameter is displayed when you press + and – again simultaneously. 5. Repeat steps 2 to 4 to display and change additional parameters. 6. Press + or – until “End” is displayed, and then press + and – simultaneously to save the change and exit parameter entry mode. 10 seconds after the last display or setting, all changes are saved and the thermostat will leave parameter setting mode. Para- meter Description Factory setting Setting range Adj  P01 Control sequence 2-pipe…: [0…3] 1 (Cooling only) 4-pipe:. [2…4] 4 (Heating & cooling) 0 = Heating only 1 = Cooling only 2 = Manual heating or cooling 3 = Auto changeover 4 = Heating & cooling P02 Mode selection by user via operating mode button 1 (Comfort, Protection) 1 = Comfort, Protection 2 = Comfort, Energy Saving, Protection P04 Selection of °C or °F °C 0 = °C 1 = °F P05 Sensor calibration 0.0 °C – 3 ... +3 °C P06 Standard temperature display 0 (Room temp.) 0 = Room temperature 1 = Setpoint P08 Comfort basic setpoint 21 °C 5 ... 40 °C P09 Minimum setpoint limitation in Comfort (WminComf) 5 °C 5 ... 40 °C P10 Maximum setpoint limitation in Comfort (WmaxComf) 35 °C 5 ... 40 °C P11 Setpoint of heating in Energy Saving (WheatEco) 15 °C OFF, 5 °C…WcoolEco P12 Setpoint of cooling in Energy Saving (WcoolEco) 30 °C OFF, WheatEco…40°C P13 *** Electrical heater in cooling mode ON OFF = disabled ON = enabled P14 Button lock (Press operating mode button for 7 seconds to lock or unlock the buttons) 0 (Disabled) 0 = Disabled 1 = Auto lock 2 = Manual lock *** Parameter P13 is only displayed for application "2-pipe with el heater". All temperature settings in increments of 0.5 °C.  Please record all changes you make!