Instruction sheet [PDF] (6 pages)
- Updated: 09.04.2026
Document Preview & Text Transcription
Signify Classified - Internal
www.lumec.com
page
12/12/2019
1
TULS/TULM/TULL
IMPORTANT: FOR YOUR PROTECTION, YOU MUST CAREFULLY READ ALL WARNINGS AND INSTRUCTIONS IN THEIR
ENTIRETY PRIOR TO INSTALLATION, OPERATION, SERVICE OR MAINTENANCE. FAILURE TO DO SO CAN RESULT IN DEATH,
PERSONAL INJURY AND PROPERTY DAMAGE. If you do not understand these warnings and instructions, or if additional
information is desired, please contact Signify, Lumec. [email protected] phone 1-833-744-6439.
INSTRUCTION SHEET FOR MOUNTING SLIP-FITTER TUL
SLF – 442295030931 Rev 3
•
Installation, service and maintenance of luminaires must be performed by a qualified professional and in accordance with all federal, state and local
laws, regulations and electrical codes. This professional should be familiar with the construction and operation of this product and any hazards
involved. If not qualified, do not attempt installation, service or maintenance.
•
To reduce the risk of death, personal injury or property damage from fire, electric shock, falling parts, cuts, abrasions and other hazards, please read
all warnings and instructions included with the luminaire, on the luminaire’s packaging and affixed to the luminaire itself.
•
Maintenance of the luminaires should be performed by person(s) familiar with the luminaire’s construction and operation and any hazards involved.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•
Disconnect or turn off power before attempting any installation, service or
maintenance.
•
Verify that supply voltage is correct by referencing the luminaire label
information.
•
Make all electrical and ground connections in accordance with the National
Electrical Code (NEC) and any other applicable laws, regulations or codes.
•
All wiring connections should be capped with UL-approved wire connectors.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•
Wear gloves and safety glasses at all times when removing luminaire
from carton, installing, servicing or performing maintenance.
•
▪Avoid direct eye exposure to the light source while it is on.
CAUTION
RISK OF PRODUCT DAMAGE
• Never connect luminaires and/or components under load with supply voltage turned on.
• Do not mount or support these luminaires in a manner that can cut the outer jacket or damage wire insulation.
• Do not restrict fixture ventilation. Allow for some volume of airspace around luminaire. Avoid covering luminaire with insulation, foam or other material that will
prevent convection or conduction cooling.
• Do not exceed luminaire maximum ambient temperature.
• Do not modify the luminaire.
• Only use luminaire in its intended application and location.
• Led products are polarity sensitive. Ensure proper polarity before installation.
• Electrostatic Discharge (ESD) can damage LED. Personal grounding equipment must be worn during all installation and servicing of the luminaire.
• Do not touch individual electrical components as this can cause ESD, shorten LED life, or impact LED performance.
• Some components inside the luminaire may not be serviceable. In the unlikely event your luminaire may require service, stop using it immediately and contact
Signify.
• Always read the luminaires complete installation instructions prior to installation for any additional luminaire specific warnings.
• In the case of HID or Fluorescent luminaires, regular re-lamping is required to keep luminaire operating within safe limits
• Do not install damaged product. Handling and installing damaged products can potentially increase the risks mentioned In case of damage and/or missing parts
upon arrival of the luminaire.
• These instructions do not purport to cover all details or variations in equipment nor to provide every possible contingency to meet in connection with installation,
operation or maintenance.
• Please see luminaire specific Installation and Maintenance Instruction for additional warnings or any applicable FCC or regulatory statements. Failure to follow
any of these Instructions could void luminaires warranties.
Luminaire Maintenance
• Regular luminaire maintenance programs are recommended.
• It is recommended to clean the outside of the luminaire and the refractor/lens.
• Frequency of cleaning will depend on ambient dirt level and minimum light output which is acceptable to user.
• If clean water is not sufficient for cleaning, use a neutral, synthetic, not-scratching and not-abrasive cleaning substance.
• Never use alkaline and/or acetous cleaning substances.
• Make sure that the cleaning substance is carefully removed by rinsing with lots of clean water.
• Signify recommends using a cleaning solution that has a PH between 5 and 8.
• Recycle: For information on how to recycle electronic products and components, please visit www.epa.gov.
WARNING
RISK OF FIRE OR PERSONAL INJURY
•
Keep combustible materials away from LED/lamp & lens
•
▪Do not operate in close proximity to persons, combustible materials
or substances affected by heat or drying.
WARNING
RISK OF FIRE, ELECTRIC SHOCK OR PERSONAL INJURY
•
Allow Led/lamp & lens to cool before handling.
•
▪Do not touch enclosure or light source
•
▪Do not exceed maximum wattage marked on luminaire label.
•
▪Follow all manufacturer’s warnings, recommendations, instructions
and restrictions for driver type, burning position, mounting locations
and replacement.
Signify Classified - Internal
page
12/11/2019
2
Installation instructions
SLF – Slip Fitter Mount
TULS/TULM/TULL
Note: Tenon must be 3.75” or longer.
ELECTRICAL CONNECTION
1. Connect the black fixture lead to the input voltage
supply or Hot 1 (208V/240V/480V wiring).
2. Connect the white fixture lead to the neutral supply
or Hot 2 (208V/240V/480V wiring).
3. Connect the Green ground lead to the incoming
ground wire.
4. If Dimming is an option, connect the purple dimming
positive lead to the supply dimming positive lead and
the grey dimming negative lead to the supply dimming
negative lead.
SLF- SLIP FITTER MOUNT
5. Remove splice cover screws and splice cover to
access wire splice area.
6. Route the supply wire through the tenon. Secure the
supply wire to keep from sliding back down the pole.
Route wire through slip fitter arm into splice area.
7. Holding routed wires in splice area, carefully lower
luminaire onto tenon. Check to ensure that wires are
not pinched between inside of slip fitter and top of
tenon and that luminaire and wires rotate.
NOTE:
Install luminaire as per traffic direction label
Screws
Latches
11 ft.-lbs
Note: 7 pin NEMA Twist Lock Receptacle option aiming
restricted to 0-90o per ANSI C136.10
Signify Classified - Internal
page
12/11/2019
3
SLF – Slip Fitter Mount
TULS/TULM/TULL
www.lumec.com
VERTICAL ANGLE ADJUSTMENT
HORIZONTAL ANGLE ADJUSTMENT
aiming sight
HORIZONTAL ANGLE ADJUSTMENT
8. Secure the luminaire on the tenon. Using a 5/32" Allen wrench, hand tighten the Slip fitter set screws until
the tip of the screws engage the tenon. (Do not fully tighten). Using the built-in aiming sight at the top edge of
the luminaire rotate the luminaire horizon-tally until the desired aiming target is centered in the aiming
window. Tighten the set screws to 11 ft.-lbs when the final horizontal position is set.
9. Make electrical connections per Electrical Connection steps 1, 2, 3 and 4 (pg. 2).
VERTICAL ANGLE ADJUSTMENT
NOTE: Angle adjustment can be made before luminaire installation.
10. After the luminaire is installed, the vertical angle of the luminaire can be adjusted within the limits of the
aiming diagram (pg.2) in 5° increments.
11. To adjust the vertical angle, loosen the 1/2–13 X 1.75” socket cap bolt located in slip fitter Arm. (Do NOT
remove bolt.) Loosen only enough to allow rotation of cast teeth.
12. Using the aiming sight and the degree indicators shown as a guide, rotate vertically the luminaire to the
desired position and retighten the bolt loosened in Step 11 to 47 ft.-lbs.
47 ft.-lbs
Installation instructions
Signify Classified - Internal
www.lumec.com
page
12/12/2019
4
TULS/TULM/TULL
AVERTISSEMENT
RISQUE D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE
▪Débranchez ou coupez le courant avant toute intervention d’installation, de réparation
ou d’entretien.
▪Assurez-vous que la tension d’alimentation est adéquate en vous référant aux
renseignements sur l’étiquette du luminaire.
▪Faites toutes les connexions électriques et de mise à la terre en conformité avec les exigences
du Code national de l’électricité et de tout autre règlement, loi ou code qui s’applique.
▪Toutes les connexions de câblage doivent être munies de capuchons de connexion
homologués UL.
AVERTISSEMENT
RISQUE DE BLESSURE
▪Portez des gants et des lunettes de sécurité en tout temps pour retirer le
luminaire de son carton d’emballage, l’installer, le réparer ou l’entretenir.
▪Évitez toute exposition directe des yeux à la source d’éclairage pendant que
l’appareil est allumé.
ATTENTION
RISQUE D’ENDOMMAGEMENT DU PRODUIT
▪Ne connectez jamais les luminaires et/ou leurs composants en charge quand la tension d’alimentation est activée.
▪N’installez pas et ne supportez pas ces luminaires de façon que cela puisse couper la gaine extérieure ou endommager l’isolant des fils.
▪Ne bloquez pas la ventilation autour de l’appareil. Prévoyez de l’espace libre autour du luminaire. Évitez de recouvrir le luminaire avec de l’isolant, de la mousse ou un
autre matériau qui empêcherait de refroidir l’appareil par convection ou conduction.
▪Veillez à ne pas dépasser la température ambiante maximale du luminaire.
▪Ne modifiez pas le luminaire.
▪N’utilisez le luminaire que selon l’application et l'emplacement prévus.
▪Les produits de type DEL sont sensibles à la polarité. Veillez à la bonne polarité avant d’installer l’appareil.
▪Les Décharges Électrostatiques (DES) peuvent endommager une DEL. Portez un équipement personnel de mise à la terre pendant toute intervention d’installation ou de
réparation sur le luminaire.
▪Ne touchez pas aux composants électriques individuels, étant donné que ceci peut causer une DES, raccourcir la durée de vie des DEL ou nuire à leur rendement.
▪Certains composants internes du luminaire peuvent ne pas être réparables. Aussi peu probable que ça pourrait l’être, si votre luminaire a besoin de réparation, cessez de
l’utiliser immédiatement et communiquez avec Signify [email protected] composez le 1-833-744-6439.
▪Lisez toujours les directives d’installation complètes du luminaire avant de l’installer afin de connaître tous ses avertissements spécifiques supplémentaires.
▪Dans le cas des luminaires à lampe DHI ou fluorescente, il est nécessaire de remplacer les lampes régulièrement afin que l’appareil continue de fonctionner de façon
sécuritaire
▪N’installez pas un produit endommagé. La manipulation et l’installation de produits endommagés peuvent potentiellement augmenter les risques mentionnés. En cas de
dommage ou de pièces manquantes sur réception du luminaire, veuillez communiquer avec Signify [email protected] composez le 1-833-744-6439.
▪Ces directives ne sont pas censées couvrir tous les détails ou variations de l’équipement ni prévoir toutes les éventualités possibles en rapport avec l’installation,
l’utilisation ou l’entretien de l’appareil. Si des renseignements additionnels sont requis, ou si des problèmes particuliers surviennent qui ne sont pas couverts suffisamment
aux fins prévues par l’acheteur ou le propriétaire, veuillez soumettre la question ou le problème à avec Signify [email protected] composez le 1-833-744-6439.
▪Veuillez consulter les directives d’installation et d’entretien spécifiques du luminaire afin d’obtenir des avertissements supplémentaires et d’y lire tout énoncé
réglementaire ou de la FCC qui s’applique. Tout défaut de respecter l’une quelconque de ces directives pourrait annuler les garanties des luminaires.
Entretien du luminaire
▪Il est recommandé d’appliquer des programmes d’entretien régulier des luminaires.
▪Il est recommandé de nettoyer l’extérieur du luminaire ainsi que son réfracteur/sa lentille.
▪La fréquence du nettoyage dépend du degré de saleté ambiant et du rendement lumineux minimal jugé acceptable par l’utilisateur.
▪Si l’utilisation d’eau propre n’est pas suffisante pour le nettoyage, utilisez une substance nettoyante neutre, synthétique, non rayante et non abrasive.
▪N’utilisez jamais de substances nettoyantes alcalines et/ou acéteuses.
▪Veillez à ce que la substance nettoyante soit éliminée à fond en rinçant la surface à grande eau propre.
▪Signify recommande d’utiliser une solution de nettoyage au pH entre 5 et 8.
▪Recyclez : Pour obtenir des renseignements sur la façon de recycler les produits et les composants électroniques, veuillez visiter www.epa.gov or http://epra.ca/.
AVERTISSEMENT
RISQUE D’INCENDIE OU DE BLESSURE
▪Gardez toute matière combustible éloignée de la DEL/lampe et de la lentille.
▪N’utilisez pas cet appareil tout près d’une personne, d’une matière combustible ou
d’une substance qui est sensible à la chaleur ou à la sécheresse.
AVERTISSEMENT
RISQUE D’INCENDIE, DE DÉCHARGE ÉLECTRIQUE OU DE BLESSURE
▪Laissez refroidir la DEL/lampe et la lentille avant toute manipulation.
▪Ne touchez pas au boîtier ni à la source d’éclairage.
▪Ne dépassez pas la puissance maximale indiquée sur l’étiquette du
luminaire.
▪Suivez tous les avertissements, les recommandations, les directives et les
restrictions du fabricant pour ce qui est du type de régulateur, de la position
d’allumage, des emplacements d’installation et du remplacement.
IMPORTANT: POUR VOTRE PROTECTION, VOUS DEVEZ LIRE ATTENTIVEMENT ET INTÉGRALEMENT TOUS LES AVERTISSEMENTS ET TOUTES LES DIRECTIVES
PRÉALABLEMENT À L’INSTALLATION, À L’UTILISATION, À L’ENTRETIEN OU À LA RÉPARATION DE L’APPAREIL. LE DÉFAUT D’OBSERVER L’EXIGENCE CI-DESSUS PEUT
ENTRAÎNER DES BLESSURES, VOIR LA MORT, ET CAUSER DES DOMMAGES MATÉRIELS. Si vous ne comprenez pas ces avertissements et directives, ou désirez des
renseignements supplémentaires, veuillez communiquer avec Signify [email protected] composez le 1-833-744-6439.
▪L’installation, la réparation et l’entretien des luminaires doivent être effectués par un professionnel dûment qualifié et en conformité avec l’ensemble des lois, des
règlements et des codes de l’électricité fédéraux, provinciaux et locaux. Ce professionnel doit être familiarisé avec la construction et l’utilisation de ce produit et avec
tout danger connexe. Aucune personne non qualifiée ne doit tenter d’installer ou de réparer ce produit, ou d’en faire l’entretien.
▪Afin de réduire les risques de décès, de blessure ou de dommages matériels causés par le feu, les décharges électriques, la chute de pièces, les coupures et frottements,
et autres dangers, veuillez lire tous les avertissements et directives qui sont inclus avec le luminaire, sur son emballage et aussi apposés sur l’appareil lui-même.
▪L’entretien des luminaires doit être effectué par des personnes qui sont familiarisées avec la construction et l’utilisation de l’appareil, ainsi qu’avec tous les dangers
connexes.
INSTRUCTION D’INSTALLATION POUR SUPPORT PIVOTANT
SLF – 442295030931 Rev 3
Pages Preview: