INSTALLER INSTRUCTIONS
CONTENTS
1
DESCRIPTION OF THE BOILER . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 88
2
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 91
3
CHARACTERISTICS . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 101
4
USE AND MAINTENANCE . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . pag. 104
IMPORTANT
When carrying out commissioning of the boiler, you are highly recommended to perform the following checks:
– Make sure that there are no liquids or inflammable materials in the immediate vicinity of the boiler.
– Make sure that the electrical connections have been made correctly and that the earth wire is connected to a
good earthing system.
– Open the gas tap and check the soundness of the connections, including that of the burner.
– Make sure that the boiler is set for operation for the type of gas supplied.
– Check that the flue pipe for the outlet of the products of the combustion is unobstructed and has been properly
installed.
– Make sure that any shutoff valves are open.
– Make sure that the system is charged with water and is thoroughly vented.
– Check that the circulating pump is not locked (CAUTION: Remember to release the pump coupled with the control
panel, if necessary, to protect the electronic control card).
– Purge the system, bleeding off the air present in the gas pipe by operating the pressure relief valve on the gas
valve inlet.
– Check that the syphened drip is fully filled with water. If necessary, fill it via the special opening.
FONDERIE SIME S.p.A. of Via Garbo 27 - Legnago (VR) - Italy declares that its hot water boilers, which bear the CE
mark under Gas Directive 90/396/CEE and are fitted with a safety thermostat calibrated to a maximum of 110°C,
are not subject to application of PED Directive 97/23/CEE as they meet the requirements of article 1 paragraph
3.6 of the Directive.
PLANET DEWY 30/50 BF - ENGLISH
88
IT
ES
PT
GB
1.1
INTRODUCTION
“PLANET DEWY 30/50 BF” with stainless
steel hot water tank, boilers are premix con-
densation thermal appliances which use
microprocessor technology for function
control and management. They comply with
the european directives 90/396/CEE,
89/336/CEE, 73/23/CEE, 92/42/CEE
and with the european specification EN 483
- EN 625. They may be fuelled by natural gas
(methane gas) or propane (G31).
The instructions given in this manual are
provided to ensure proper installation and
perfect operation of the appliance.
1
DESCRIPTION OF THE BOILER
1.2
DIMENSIONS
100 152 70100 78
E U M R G
110
79
S3
C
156
90
865
600
ø 60/100
222
450
460
=
=
934
297
22
850
5
Fig. 1
CONNECTIONS
R
C.H. return
G 3/4” (UNI-ISO 228/1)
M
C.H. flow
G 3/4” (UNI-ISO 228/1)
G
Gas connection
G 3/4” (UNI-ISO 228/1)
E
D.H.W. inlet
G 1/2” (UNI-ISO 228/1)
U
D.H.W. outlet
G 1/2” (UNI-ISO 228/1)
C
Ricirculation
G 1/2” (UNI-ISO 228/1)
S3
Condensation outlet
ø 25
89
IT
ES
PT
GB
1.3
TECHNICAL FEATURES
30 BF
Heat output nominal (80-60°C)
kW (kcal/h)
29.2 (25,112)
Heat output nominal (50-30°C)
kW (kcal/h)
32.2 (27,690)
Heat output minimum (80-60°C)
kW (kcal/h)
7.6 (6,540)
Heat output minimum(50-30°C)
kW (kcal/h)
8.4 (7,220)
Nominal heat output
kW (kcal/h)
30.0 (25,800)
Minimum heat output
kW (kcal/h)
8.0 (6,880)
Efficiency nominal/minimum output (80-60°C)
%
94.5 - 97.2
Efficiency nominal/minimum output (50-30°C)
%
104.9 - 107.2
30% yield (50-30°C)
%
106.7
Termal efficiency (CEE 92/42 directive)
####
Class NOx
5
Smokes temperature maximum (80-60°C)
°C
68
Smokes temperature minimum(80-60°C)
°C
69
Smokes temperature maximum (50-30°C)
°C
47.3
Smokes temperature minimum (50-30°C)
°C
46.9
Smokes flow
kg/h
50.2
CO2 maximum/minimum G20
%
9.1/9.1
CO2 maximum/minimum G31
%
10.0/10.0
Adsorbed power consumption
W
160
Electrical protection grade
IP
X4D
CE certification
n°
1312BP4098
Category
II2H3P
Type
B23-53/C13-33-43-53-83
C.H.
Maximum water head
bar
3
Maximum temperature
°C
85
Water content boiler
l
10.0
C.H. setting range
°C
20/80
Expansion vessel capacity
l
10
Expansion vessel pressure
bar
1
Gas consumption nominal/minimum G20
m3/h
3.17/0.84
Gas consumption nominal/minimum G31
kg/h
2.33/0.62
D.H.W.
Maximum pressure
bar
7.0
D.H.W. flow rate (EN 625)
l/min
16.0
Continuous D.H.W. flow rate ∆t 30°C
l/min
14.1
Hot water tank contents
l
50
Tempo di riscaldamento acqua nell’accumulo da 25 a 55 °C
min
3’ 45”
D.H.W. setting range
°C
30/60
Capacity of hot water expansion tank
l
2
Gas consumption nominal/minimum G20
m3/h
3.17/0.84
Gas consumption nominal/minimum G31
kg/h
2.33/0.62
GAS PRESSURE END NOZZLES
Gas supply pressure G20
mbar
20
Gas supply pressure G31
mbar
37
Nozzles quantity
n°
1
Nozzles diameter G20
ø
7.0
Nozzles diameter G31
ø
5.0
WEIGHT
kg
70.1