SMA HM-20 Manuals

2 pdf manual(s) SMA HM-20 for free download (Document Types: Operating manual, Quick reference manual)

SMA HM-20 Operating manual Thumbnail

SMA HM-20 Operating manual [PDF] (127 pages)

  • Identifier: id-897751
  • Brand: SMA
  • Device: SMA HM-20 Measuring Instruments
  • Type: Operating manual, PDF
  • Key Aspects: Basic Configuration Guidelines, Environmental Factors and Restrictions, Control Panel and Interface Navigation
  • UPD Date: 08.05.2026
  • Source File: 846806.pdf
  • Pages: 127
  • Description: Setup instructions for the SMA HM-20.
Pages Preview:
  • SMA HM-20 Operating manual preview - page 2
  • SMA HM-20 Operating manual preview - page 3
  • SMA HM-20 Operating manual preview - page 4
  • SMA HM-20 Operating manual preview - page 5
  • SMA HM-20 Operating manual preview - page 6
  • SMA HM-20 Operating manual preview - page 7
  • SMA HM-20 Operating manual preview - page 8
  • SMA HM-20 Operating manual preview - page 9
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Reset SUNNY HOME MANAGER 2.0 Operating Manual SUNNY HOME MANAGER 2.0 HM-20-BE-en-10 | Version 1.0 ENGLISH
SMA HM-20 Quick reference manual Thumbnail

SMA HM-20 Quick reference manual [PDF] (2 pages)

  • Identifier: id-885903
  • Brand: SMA
  • Device: SMA HM-20 Measuring Instruments
  • Type: Quick reference manual, PDF
  • Key Aspects: Cleaning and Sanitization Methods, End-of-Life Handling and Disposal, Performance Optimization Tips
  • UPD Date: 07.05.2026
  • Source File: 858655.pdf
  • Pages: 2
  • Description: Technical operation manual for the SMA HM-20.
Pages Preview:
  • SMA HM-20 Quick reference manual preview - page 2
Document Preview & Text Transcription (Main Page)
Click to expand and read text
HM-20-IS-en-10 | Version 1.0 SMA Solar Technology AG SUNNY HOME MANAGER 2.0 Quick Reference Guide Rev.0001 This document is valid for the Sunny Home Manager 2.0* (HM-20) from firmware version 2.00.00.R. Only qualified persons with the following skills are allowed to perform the tasks de- scribed in this document: • Training in the installation and commissioning of electrical devices and installa- tions • Training in how to deal with the dangers and risks associated with installing and using electrical devices and installations • Knowledge of the applicable standards and directives • Knowledge of and compliance with this document and all safety information The Sunny Home Manager 2.0 is the central device responsible for energy man- agement in households with a PV system for self-consumption. The Sunny Home Manager 2.0 carries out the following basic tasks: • Collection of energy- and power measured values in the interconnected house- hold • Energy monitoring: Presentation of energy flows via Sunny Portal • Energy management: Automatic control of interconnected household loads with the aim of energy efficiency optimization • Dynamic limiting of the active power feed-in • Active power measurement via integrated measuring unit with direct connection up to 63 A limiting current • Use of current transformers necessary for applications above 63 A • Interconnection of loads via EEBus and SEMP • Support of the WLAN smart plugs Edimax SP-2101W The Sunny Home Manager 2.0 does not support S0- or D0 energy meters, Plug- wise products or Miele@home devices. The Sunny Home Manager 2.0 is not equipped with a Bluetooth interface. The Sunny Home Manager 2.0 is not an ener- gy meter for power consumption in the sense of the EU directive 2004/22/EG (MID). The Sunny Home Manager 2.0 may not be used for billing purposes. The data collected by the Sunny Home Manager 2.0 relating to the power generated by your PV system may deviate from the data of the main energy meter, which is used for billing purposes. The Sunny Home Manager 2.0 may only be connected to the subdistribution of the household on the load side behind the energy meter of the electric utility company. The Sunny Home Manager 2.0 must be installed in a switch cabinet. It is possible to use the Sunny Home Manager 2.0 in delta IT grids. When using the Sunny Home Manager 2.0 in delta IT grids, the cumulative power values are cor- rectly measured. Due to the measuring principle of the Sunny Home Manager 2.0, other measured values may be incorrect. The Sunny Home Manager 2.0 is approved for use in all EU member states and Australia. Only use the Sunny Home Manager 2.0 in accordance with the informa- tion provided in the enclosed documentation. Any other application may cause per- sonal injury or property damage. Alterations to the product, e.g. modifications or conversions, are only permitted with the express written permission of SMA Solar Technology AG. Any use of the prod- uct other than that described in the Intended Use section does not qualify as appro- priate. The enclosed documentation is an integral part of the product and must be read and observed. Keep in a convenient place for future reference. The type label must remain permanently attached to the product. The latest version of this document and the comprehensive manual for installation, commissioning, configuration and decommissioning are to be found in PDF format at www.SMA-Solar.com. Links to additional information can be found at www.SMA-Solar.com: This section contains safety information that must be observed at all times when working on or with the product. To prevent personal injury and property damage and to ensure long-term operation of the product, read this section carefully and observe all safety information at all times. • 1 x Sunny Home Manager 2.0 (HM-20) • 1 x quick reference guide Contact your specialist dealer if you find any damage. Status LED ( ): • Glowing green: Sunny Home Manager 2.0 is switched on. • Flashing green: Firmware is being updated. • Glowing red: Sunny Home Manager 2.0 is starting up. • Flashing red: An error has occurred. COM LED ( ): • Off: No Ethernet connection established. • Glowing green: Ethernet connection established. • Flashing green: The Sunny Home Manager 2.0 is sending or receiving data. Performance LED ( ): • Off: No system registered in Sunny Portal. • Flashing green: Energy management in the Sunny Home Manager 2.0 run- ning smoothly. • Flashing green: An error has occurred. The error has already been reported to Sunny Portal. • Glowing red: An error has occurred. The error has not yet been reported to Sunny Portal. • Flashing red: No connection to Sunny Portal established. Refer to the "Troubleshooting" section for error diagnosis. • Mount the Sunny Home Manager 2.0 on the top-hat rail. To do so, hook the Sunny Home Manager 2.0 onto the top edge of the top-hat rail and press down until it snaps into place. ☐ The Sunny Home Manager 2.0 is supplied with current via the line conductor L1. At least the line conductor L1 and the neutral conductor must be connected in order that the Sunny Home Manager 2.0 switches on. ☐ When using fine stranded wire, bootlace ferrules must be used. ☐ The screw terminals must be retightened after six to eight weeks. Installation using the integrated measuring unit The following figure shows a connection example in TN and TT grid configurations in the case of installation at the grid-connection point when using the integrated measuring unit (recommended). For exact connection specifications, contact your electric utility company. Procedure: 1. Connect the conductors to the Sunny Home Manager 2.0. Observe the permit- ted connection cross-section and torque for screw terminals (see Section "Tech- nical Data"): • In a three-phase utility grid, connect the line conductors L1, L2 and L3 and the neutral conductor to the Sunny Home Manager 2.0 in accordance with the wiring diagram. • In a single-phase utility grid, connect the line conductor L1 and the neutral conductor to the Sunny Home Manager 2.0 in accordance with the wiring diagram. VALIDITY * Also referred to in this document as the product. TARGET GROUP SYMBOLS USED Indicates a hazardous situation that, if not avoided, will re- sult in death or serious injury. Indicates a hazardous situation that, if not avoided, can re- sult in death or serious injury. Indicates a hazardous situation that, if not avoided, can re- sult in minor or moderate injury. Indicates a situation that, if not avoided, can result in prop- erty damage. Information that is important for a specific topic or goal, but is not safety-relevant. ☐ Indicates a requirement for meeting a specific goal. ☑ Desired result. ✖ A problem that might occur. INTENDED USE ������ ADDITIONAL INFORMATION Document title Document type SUNNY HOME MANAGER 2.0 Operating manual SMA SMART HOME - The System Solution for more Independence Planning guidelines SMA SMART HOME - Home appliance energy management using EEBus Technical information SMA SMART HOME - Battery Charging Management with Time-of-Use Energy Tariffs Technical information SMA SMART HOME - Load Control via CAN Time Period. Example: Pool Pump Technical information SMA SMART HOME - Load Control via MUST Time Period. Example: Washing Machine Technical information SMA SMART HOME Load Control Using Relays or Contactors. Example: Heating Rod Technical information SAFETY INFORMATION DANGER Danger to life due to electric shock Lethal voltages are present in the live components. • Disconnect the connection point from voltage sources and make sure it cannot be reconnected. • Before performing any work on the Sunny Home Manager 2.0, discon- nect the grid side from all voltage sources using an installed disconnect switch. • Ensure that the conductors to be connected are de-energized. • Only use the Sunny Home Manager 2.0 in a dry environment and keep it away from moisture. • Install the Sunny Home Manager 2.0 in the switch cabinet only and en- sure that the connection areas for the line conductors and the neutral conductor are behind a cover or have contact protection. • Disconnect the Sunny Home Manager 2.0 from voltage sources before cleaning. The Energy Meter must be cleaned with a dry cloth only. • Observe the prescribed minimum clearance between the network cable and live installation components, or use suitable insulation. DANGER Danger to life due to electric shock if external disconnect switch is missing Lethal voltages are present in the live components of the Sunny Home Manager 2.0. • Install an external disconnect switch between the Sunny Home Manager 2.0 and the grid-connection point. The external disconnect switch must be close to the Sunny Home Manager 2.0 and easily accessible. WARNING Danger to life due to electric shock Overvoltages (e. g. in the case of a flash of lightning) can be further con- ducted into the building and to other connected devices in the same net- work via the network cable if there is no overvoltage protection. • Ensure that all devices in the same network are integrated in the existing overvoltage protection. • When laying the network cable outdoors, attention must be given to suit- able overvoltage protection at the network cable transition outdoors to the network inside the building. WARNING Risk of fire due to dirty or oxidized contact surfaces of live alumi- num conductors Connecting dirty or oxidized contact surfaces with aluminum conductors re- duces the ampacity of the live terminals, thereby increasing the transition re- sistances. This can cause components to overheat and catch fire. • The contact surfaces are to be cleaned, brushed, and treated with acidic and alkaline substances (e.g. petroleum jelly or special thermal grease). WARNING Fire risk If a fuse is missing or incorrect and a fault occurs, a fire may be caused. This can result in death or serious injury. • Fuse the Sunny Home Manager 2.0 line conductor with a fuse or a se- lective circuit breaker with max. 63 A. PRODUCT DESCRIPTION SCOPE OF DELIVERY TECHNICAL DATA Communication Ethernet Nominal voltage 230 V AC / 400 V AC Frequency 50 Hz (± 5%) Self-consumption < 3 W Limiting current / line conductor 63 A Connection cross-section with current trans- formers See recommendations of the cur- rent transformer manufacturer Connection cross-section without current transformers 10 mm² to 16 mm² Max. cable length with current transformers 3 m Torque for screw terminals 2 Nm Weight 0.30 kg Dimensions (W x H x D) 70 mm x 88 mm x 65 mm Ambient temperature in operation -25°C to +40°C Ambient temperature during transport/stor- age -25°C to +70°C Relative humidity* * non-condensing 5% to 90% Maximum operating altitude above mean sea level 2000 m Protection class II Degree of protection** ** in accordance with IEC 60529 IP2X LED SIGNALS L1 L2 L3 N L1 L2 L3 SUNNY HOME MANAGER 2.0 Reset B A C D E A F A B C E F : Connection area for line conductors and neutral conductor : Network terminal ( ) : Reset button : COM LED : Status LED Ethernet : D Performance LED MOUNTING INFORMATION ON CONNECTION AND COMMISSIONING ELECTRICAL CONNECTION FOR APPLICATIONS UP TO 63 A L1 L2 L3 N SUNNY HOME MANAGER 2.0 L1 L2 L3 Reset L1 L2 L3 N L1 L2 L3 L1 L2 L3 L1 L2 L3 N Router/ Switch Sunny Portal Internet Household Disconnect switch Energy meter of the electric utility company Main breaker (three-phase) OUT IN Utility grid Inverters Sunny Home Manager 2.0 as purchased electricity and feed-in meter L1 L2 L3 N OUT IN , , : Line conductor : Neutral conductor : Meter output, load side : Meter input, grid side WLAN Ethernet

Similar Manuals in the Measuring Instruments Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Keysight U8903A

Keysight U8903A User Guide (Operation & user’s manual), @MI15XM

167 337 78 27-05-2026 view all manuals
MGL Avionics Ultra Horizon XL

MGL Avionics Ultra Horizon XL Manual (Owner's manual), @371XU4

73 954 201 06-08-2026 view all manuals
Hesai Pandar64

Hesai Pandar64 Manual (Operation & user’s manual), @G47PFA

77 533 112 20-06-2026 view all manuals
Endress+Hauser Prosonic FMU 860

#M4FZ61: Prosonic FMU 860 Measuring Instruments Technical information

16 1445 261 17-07-2026 view all manuals
Viavi G3-GS-2P40-1152T

PDF Guide (@29M5JJ), Viavi G3-GS-2P40-1152T Storage (11-06-2026)

380 662 146 11-06-2026 view all manuals
LaserLiner ClimaHome-Check

ClimaHome-Check (Measuring Instruments ePDF Guide, #5O44HE)

52 189 44 21-03-2026 view all manuals