ATyS p
800 A - 3200 A
1
2
800 A
1000 A
1250 A
1600 A
2000 A
2500 A
3200 A
2x185
-
-
-
-
-
-
2x50x5
2x63x5
2x63x7
2x100x5
3x100x5
2x100x10 3x100x10
4x185
4x185
4x185
6x185
-
-
-
63
63
63
100
100
100
100
M8
M8
M10
M12
M12
M12
M12
73.46/8.3
73.46/8.3 177.02/20
354.04/40
354.04/40 354.04/40 354.04/40
115.06/13 115.06/13 230.13/26
398.30/45
398.30/45 398.30/45 398.30/45
549702C
Motorised Source Changeover Switch
Automatic Transfer Switching Equipment
EN
Installation and Commissioning
Installation
Power Terminal Connections
M8 Type Z
M8
Caution: ensure that the
product is installed on a
flat rigid surface.
Recommended
orientation
OK
OK
www.socomec.com
To download, brochures, catalogues
and technical manuals:
http://www.socomec.com/en/
documentation-atys-p
STEP 1
Cabinet / Back
Plate Installation
STEP 3
COMMAND /
CONTROL
terminal
connections
STEP 2
Power Terminal
Connections
STEP 4
Power SUPPLY and
ATS Controller
Terminal
Connections
STEP 5
CHECK
STEP 6
PROGRAMMING
A - Software
B - Keypad
STEP 7A
AUT Mode
(Automatic Control)
STEP 7C
Manual Mode
STEP 7B
AUT Mode
(Remote Control)
STEP 7D
Padlocking Mode
FRAME B6
FRAME B7
FRAME B8
Minimum cable section Cu (mm²)
Recommended cable section Cu (mm²)
Maximum Cu cable cross-section (mm²)
Maximum Cu busbar width (mm)
Type of screw
Recommended tightening torque (lb.in/N.m)
Maximum tightening torque (lb.in/N.m)
To be connected using terminal lugs, rigid or flexable busbars.
Preliminary operations
Check the following upon delivery and after removal of the
packaging:
- Packaging and contents are in good condition.
- The product reference corresponds to the order.
- Contents should include:
Qty 1 x ATyS p
Qty 1 x Emergency handle and fixing clip
Quick Start instruction sheet
Warning
Risk of electrocution, burns or injury to persons and /
or damage to equipment.
This Quick Start is intended for personnel trained in the
installation and commissioning of this product. For further
details refer to the product instruction manual available on
the SOCOMEC website.
• This product must always be installed and
commissioned by qualified and approved personnel.
• Maintenance and servicing operations should be
performed by trained and authorised personnel.
• Do not handle any control or power cables connected to
the product when voltage may be, or may become
present on the product, directly through the mains or
indirectly through external circuits.
• Always use an appropriate voltage detection device to
confirm the absence of voltage.
• Ensure that no metal objects are allowed to fall in the
cabinet (risk of electrical arcing).
- For 800 - 3200 A (Uimp = 12 kV). Terminations must respect
a minimum of 14 mm clearance from live parts to parts
intended to be earthed and between poles.
Failure to observe good enginering practises as well as to
follow these safety instructions may expose the user and
others to serious injury or death.
Risk of damaging the device
In case the product is dropped or damaged in any way it is
recommended to replace the complete product.
Accessories
• Bridging bars and connection kits.
• Control voltage transformer (400 VAC 230 VAC).
• DC power supply (12/24 VDC 230 VAC).
• Phase barriers.
• Terminal shrouds / Terminal screens.
• Auxiliary contacts (Additional).
• Padlocking in 3 positions (I - O - II).
• Lockout accessories (RONIS - EL 11 AP).
• Door escutcheon frame.
• ATyS D20 Interface (remote control / display unit).
• RJ45 cable for ATyS D20.
• Voltage sensing kit.
• Current transformers.
• Plug-in optional modules: RS485 MODBUS
communication, 2 inputs/2 outputs, Ethernet
communication, Ethernet communication + RS485
JBUS/MODBUS gateway, Analogue outputs, Pulse
outputs.
For further details refer to the product instruction manual
under chapter "Spares and Accessories".
STEP 1
STEP 2
Clip for
storage of
the
emergency
handle
2
1
5
6
4 3 2 1
2
7
104 103
312313314315 316317
63A64A 24 14 04 13
8 9
10
RJ
102 101
106 105
417416 415414 413
64B63B
201 202
203 204205 206
208 209210
207
12
13
14
15
11
1
F1
F2
19
20
16
17
18
23
23
24
24
72 71 74
I/1-2 I/3-4 I/5-6 I/7-8
II/1-2 II/3-4 II/5-6 II/7-8
LOAD
21
22
R1 R2 S1 S2 T1 T2
Opt. 3
Opt. 2
Opt. 1
4
Opt. 4
3
2
1
Ensure that the product is in Manual Mode.
CONTROL / COMMAND Terminals
1 preferred source
2 alternate source
1. Position 0 order
2. Position 1 order
3. Position 2 order
4. Zero position priority order
5. Remote Control Enable (Priority
over Auto)
6. Product Available output (Motor)
7. Position II aux contact
8. Position I aux contact
9. Position 0 aux contact
10. O/P to ATyS D20 remote unit
11. Programmable Output Contact.
By default set to ATS Product
Available - Normally Open
12-15. Programmable Inputs 1-4
16-17. Programmable Inputs 5-6
18. Aux. Supply (207/210) to be used
with ATyS optional I/O modules
19. Contact “Start/Stop Genset” : if
S1 is not available the NC contact
(71-72) is close
20. Contact “Start/Stop Genset” : if
S1 is not available the NO contact
(71-74) is open
21. Option Module Slots 1 to 4
22. Current Transformer incoming
cable connections
23. Voltage Sensing Inputs
24. Power Supply Inputs
Power Supply, Sensing and Control wiring (ATS Controller)
Example: Control wiring for a 400 VAC application having a 3 phase and neutral supply.
Slots for optional modules
See on the back "Optional modules"
ATS Module
Control Inputs
(Programmable)
Programmable Inputs
To opt. Module/Common
Progr. Inputs (208-209)
To opt. Module positive
ATS Module
Output Contact
(Programmable)
Genset Start/Stop Signal
NC
Common
NO
Remote interface
RJ45 - to ATyS D20
ATS Voltage
Sensing Input
Source supply I
S I - Phase / Neutral
S I - Phase
S I - Phase
575 VAC (ph-ph) max
S I - Neutral / Phase
332 VAC (ph-n) max
ATS Power Supply
Input I
Power supply I - L/N
Power supply I - N/L
208-277 VAC ±20%:
50/60 Hz
Recommanded to use
SOCOMEC Voltage
Sensing Kit
(refer to ATyS p
accessories
for details)
ATS Voltage Sensing
Input
Source supply II
S II - Phase / Neutral
S II - Phase
S II - Phase
575 VAC (ph-ph) max
S II - Neutral / Phase
332 VAC (ph-n) max
ATS Power Supply
Input II
Power supply II - L/N
Power supply II - N/L
208-277 VAC ±20%:
50/60 Hz
Current Transformer
incoming cable connections
STEP 5
Check
Whilst in manual mode, check the wiring and if ok
power up the product.
LED “Power” Green: ON
LED Manuel/Fault Red: ON
STEP 3
STEP 4
ATyS D20
Remote Control /
Display Unit
ATyS Voltage
Sensing and
Power supply
Kit excludes the
need for fuses
F1 & F2.
Connect the product with a cable of section of 1,5 to 2,5 mm2.
Screw M3 - Tightening torque:
min.: 0.5 Nm - max.: 0.6 Nm / min.: 4.43 lbin - max.: 5.31 lbin
x 4
1
SETUP
2
VOLT. LEVELS
3 FREQ. LEVELS
4
PWR. LEVELS
5 TIMERS VALUE
6
I-O
7
COMM
8 DATE/TIME
NETWORK
4NBL
OV. U
I
115%
OV. F
I
105%
OV.P
I
0000 kVA
1FT
0003 SEC
IN 1
---
NO
DHCP
NO
(9)
YEAR
AUTOCONF
NO (7)
OV. U HYS
I
110%
OV. F HYS I
103%
OV.P HYS I
0000 kVA
1RT
0180 SEC
IN 2
---
NO
IP 1-2
192.168.
(9)
MONTH
NEUTRAL
AUTO
UND. U
I
085%
UND. F
I
095%
OV.P
I I 0000 kVA
2FT
0003 SEC
IN 3
---
NO
IP 3-4
.002.001
DAY
ROT PH.
---
UND. U HYS I
095%
UND. F HYSI
097%
OV.P HYS
I I 0000 kVA
2RT
0005 SEC (2)
IN 4
---
NO
GAT1-2
000.000.
HOUR
CHECK ROT
YES
UNB. U
I
00%
OV. F
I I 105%
2AT
0005 SEC (1)
IN 5
---
NO
GAT3-4
.000.000
(9)
MINUTE
NOM. VOLT
400 V
UNB. U HYS I
00%
OV. F HYS
I I 103%
2CT
0180 SEC (1)
IN 6
---
NO
MSK1-2
255.255.
SECOND
NOM. FREQ
50 Hz
OV. U
I I 115%
UND. F
I I 095%
2ST
0030 SEC (1)
IN 7
---
NO (8)
MSK3-4
.255.000
(9)
APP
M-G
OV. U HYS
I I 110%
UND. F HYS
I I 097%
ODT
0003 SEC
IN 8
---
NO (8)
ADDRESS
005
PRIO TON
NO (1)
UND. U
I I 085%
TOT
UNL
(1)
IN 9
---
NO (8)
BDRATE
9600
PRIO EON
NO (3)
UND. U HYS
I I 095%
TOT
0010 SEC (1)
IN10
---
NO (8)
STOP BIT
1
PRIO NET
1 (2)
UNB. U
I I
00%
T3T
0000 SEC (1)
IN11
---
NO (8)
PARITY
NONE
RETRANS
NO
UNB. U HYS
I I
00%
TFT
UNL
(1)
IN12
---
NO (8)
RETURN 0
NO
TFT
0600 SEC (1)
IN13
---
NO (8)
CT PRI
100
E1T
0005 SEC (3)
IN14
---
NO (8)
CT SEC
5
E2T
UNL
(3)
OUT 1
POP NO
S1=SW2
NO
E2T
0010 SEC (3)
OUT 2
---
NO (8)
BACKLGHT
INT
E3T
0005 SEC (3)
OUT 3
---
NO (8)
CODE P
1000
E5T
0005 SEC (4)
OUT 4
---
NO (8)
CODE E
0000
E6T
LIM
(4)
OUT 5
---
NO (8)
BACKUP
SAVE
E6T
0600 SEC (4)
OUT 6
---
NO (8)
E7T
0005 SEC (4)
OUT 7
---
NO (8)
LST
0004 SEC (5)
OUT 8
---
NO (8)
EET
0168 H
(6)
OUT 9
---
NO (8)
EDT
1800 SEC (6)
17
14
Modbus RS485
Programming the ATyS p
The ATyS p is to be programmed powered up and after wiring verification tests. This may either be done through the front of the ATS Controller using the keypad or with the user-friendly Easy Config
software.
For convenience, we recommend to use the Easy Config software. (Downloadable free from www.socomec.com).
The ATyS p is delivered with default setting values based on most used customer application requirements. The minimum configuration parameters that must be programmed are the type of network
and application together with the voltage and frequency nominal values. ATyS p Auto Configuration makes the setup of Volts, Hz, Phase rotation and Neutral Position quick and easy.
A - Programming with Easy Config Software
To program the ATyS p using Easy Config software simply follow the setting
boxes from left to right until all desired settings in each window have been
completed. Help pop ups are included to show the minimum and maximum
setting values allowed. The software includes most SOCOMEC products so
before programming click NEW and select the product “ATyS p” from the
list of products available.
When the ATyS p is powered and communicating, the software will include
a screen to monitor and display the ATyS p status.
Control through software (such as changing switch position I-O-II) is also
possible when in Super User Mode.
(1) When «APP» is set to «M-G»
(2) When «APP» is set to «M-M»
(3) When one of the I/P is set to «EON»
(4) When one of the I/P is set to «EOF»
(5) When one of the O/P is set to «LSC»
(6) When one of the O/P is set to «EES»
(7) If the product is in manual mode
(8) With optional I/O modules
(9) With Ethernet module
B - Programming with the ATyS p keypad
3 phase / 4 wire
3 phase / 3 wire
2 phase / 3 wire
2 phase / 2 wire
1 phase / 2 wire
4NBL
4BL
1
3
2
N
3NBL
3BL
1
3
2
2NBL
1
2
3
2BL
1
3
1BL
1
N
Optional Modules
Communication between the software and the ATyS p may be done through the Ethernet/Modbus TCP or Modbus RTU modules that are available as an option. The ETHERNET / MODBUS modules
are to be installed in one of the slots provided in the ATYS p ATS control unit.
Easy Config may be installed on a PC connected through ETHERNET or MODBUS modules for a direct ATyS configuration, either isolated with possibility to create a specific configuration for a later
upload and use in ATyS.
Note: The ATyS p may accept a total of 4 additional Input / Output modules offering an additional 8 programmable inputs and 8 programmable outputs. When including a MODBUS module the ATyS p
accepts a total of 3 I/O modules and when including the ETHERNET module a total of 2 I/O modules.
Refer to the ATyS p accessory section for details.
The Ethernet module
includes a built in Web
Server for Monitoring,
Engine Exerciser Control,
Events...
Extended I/O
2xIP 2xO/P
Modbus
RS485
Pulsed O/P
4-20mA
Ethernet/Modbus
TCP Simple
or Gateway
ATyS p devices may also be programmed through the ATS controller keypad.
This programming method is necessary for products not equipped with Ethernet or
Modbus communication modules that facilitate programming through Easy Config
software described above. The keypad is a useful interface and programming
method most especially when changing a few parameters or simply interrogating
the product.
Programming access: Press and hold for 5 s “Validation” push button (17).
Access through the keypad is possible in Automatic or Manual mode, when the
product is in a stable position (I, 0 or II) with at least one supply source available.
Programming is not accessible whilst any cycle sequence is running.
To change the configuration: Enter code (factory code = 1000) using navigation
push buttons (14).
Programming exit: Press and hold for 5 s “Validation” push button (17).
Press 5s
Go To
1
SETUP
Scroll to
AUTOCONF
Enter code
1000
Set to
YES
Press 60 ms
LEDs flash
Save :
press 5s
Setup by Auto Configuration
(Volts, Hz, Neutral pos., Ph rotation)
Note: Source I or source II must be
available to set by Auto Configuration.
Note 1: Values as listed above are the setting values by default.
Note 2: Ensure that the Default Network Setting and Application match the installation or change accordingly
before using Auto Configuration.
STEP 6
POWER
AUT
Ø 4 ... 8mm
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
REMOTE CONTROL
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
ATyS
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: ΔU ΔF %
XXX
50 Hz
60 Hz
XXXXXXXX
Motorised Changeover Switch
1600A Ref : 95054160
3x
Ø 4-8 mm
POWER
AUT
Ø 4 ... 8mm
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
REMOTE CONTROL
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
ATyS
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: ΔU ΔF %
XXX
50 Hz
60 Hz
XXXXXXXX
Motorised Changeover Switch
1600A Ref : 95054160
800 A
1000 A
1250 A
1600 A
2000 A
2500 A
3200 A
3 P
4 P
3 P
4 P
3 P
4 P
3 P
4 P
3 P
4 P
3 P
4 P
3 P
4 P
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
in
mm
C
15.39
391
15.39 391
15.39 391
15.39 391
15.39 391
15.39 391
15.39 391
15.39 391
523 20.59
523 20.59
523 20.59
523 20.59
523 20.59
523
20.59
F
19.84
504
22.99 584
19.84 504
22.99 584
19.84 504
22.99 584
23.46 596
28.19 716
23.46 596
28.19 716
23.46 596
28.19 716
23.46 596
28.19
716
M
10.04
255
13.19 335
10.04 255
13.19 335
10.04 255
13.19 335
13.66 347
18.39 467
13.66 347
18.39 467
13.66 347
18.39 467
13.66 347
18.39
467
T
3.15
80
3.15
80
3.15
80
3.15
80
3.15
80
3.15
80
4.72
120
4.72
120
4.72
120
4.72
120
4.72
120
4.72
120
4.72
120
4.72
120
X
1.87
47.5
1.87
47.5
1.87
47.5
1.87
47.5
1.87
47.5
1.87
47.5
2.09
53
2.09
53
2.11
53,5
2.11
53,5
2.11
53,5
2.11
53,5
2.11
53,5
2.11
53,5
90°
90°
I
II
0
POWER
AUT
Ø 4 ... 8mm
PROG
OK
AUT
READY
TEST ON LOAD
TEST OFF LOAD
ATyS g
Un
Auto Conf
5
1
10
14
5
1
10
13
0
1
5
10
20
60
0
1
5
10
20
60
G:
H:
E:
F:
REMOTE CONTROL
A: 3 Ph
B: 1 Ph
C: Neutral
D: Neutral
ATyS
Un N° PP / PN
1: 220 / 127
2: 380 / 220
3: 400 / 230
4: 415 / 240
5: 480 / 277
6: 208 / 120
7: 220 / 127
8: 230 / 132
9: 240 / 138
10: 380 / 220
11: 400 / 230
12: 415 / 240
13: 480 / 277
5
6
7
8
9
10
11
12
13
14
15
16
18
20
1:
2:
3:
4:
5:
6:
7:
8:
9:
10:
11:
12:
13:
14:
3
3
4
4
5
5
6
6
7
7
8
8
9
10
N°: ΔU ΔF %
XXX
50 Hz
60 Hz
XXXXXXXX
Motorised Changeover Switch
1600A Ref : 95054160
AUT
5.43
138
8.43
214
X
T
Fix. M
F
C
C
Fix. 9.84
250
11.02
280
11.02
280
0.83
21
0.83
21
0.35
9
0.49
12.5
0.33
8,5
0.62
15,75
0.62
15,75
0.20
5
0.20
5
0.63x0.43
16x11
ø 0.35
ø 9
ø 0.59
ø 15
0.59
15
ø 0.49
ø 12,5
0.59
15
1.12
28,5
1.12
28,5
0.33
8,5
1.97
50
2.36
60
3.54
90
1.30
33
1.18
30
1.18
30
1.77
45
1.77
45
0.98
25
0.98
25
1.30
33
0.39
10
800 A - 1000 A
2000 A - 3200 A
800 A - 1600 A
1250 A
1600 A -
3200 A
CORPORATE HQ CONTACT: SOCOMEC SAS 1-4 RUE DE WESTHOUSE - 67235 BENFELD, FRANCE - WWW.SOCOMEC.COM
22
23
24
25
8
7
2
3
4
5
1
6
15
20
21
17
18
13
14
19
10 11
12
9
16
Padlocking Mode
(as standard : in position O)
To enable control, close contact 312 with 317. For
contactor logic bridge contact 316 with 317. To operate:
close the contact corresponding to the desired position.
To force the product to 0 position “OFF” bridge contact
313 with 317.
Non contractual document.
Subject to change without notice.
1. MANUAL Mode LED indication. (Yellow
steady light when in Manual Mode).
2. AUTO Mode LED indication Green steady
light when in Auto mode with no timers
running.
Green flashing light when in Auto with timers
running.
3. LOCAL / REMOTE CONTROL Mode LED
indication.
Yellow steady light when in Local / Remote
control mode.
Remote control mode is achieved with the
Auto/Manu selector switched to Auto and
terminals 312 closed with terminal 317.
Remote control orders are received through
closing 314 to 316 with 317.
REMOTE Control is also achievable
through Easy Config ATyS p software when
connected to the product through Ethernet
or MODBUS. (Optional modules). Local
Control selectable and operable through the
ATyS p keypad.
4. TEST ON LOAD CONTROL Mode LED
indication. (Yellow steady light when in TON/
EON mode)
5. TEST OFF LOAD CONTROL Mode LED
indication. (Yellow steady light when in TOF/
EOF mode).
6. Load Supply On LED. (Green when the load
is supplied).
7. Switch 1 LED position indication. (Green
when in position 1).
8. Source supply I availability LED indication.
(Green when supply I voltage is within the
set limits).
9. Zero position LED indication. (Yellow when
in position 0).
10. Switch 2 LED position indication. (Green
when in position 2).
11. Source supply II availability LED indication.
(Green when supply II voltage is within the
set limits).
12. LCD Display Screen : (Status,
measurement, timers, counters, events,
faults, programming …. )
13. MODE key to shift between operation
modes.
14. Navigation Keys to browse through the
ATyS p menus without software.
15. FAULT LED indication. (Red steady light
in case of an ATS controller internal fault.
Switch the product from Auto to Manual
and back to Auto to reset a fault condition).
16. READY LED indication. (Green steady
light : Product is powered and in AUTO,
Watchdog OK, The Product is Available to
changeover).
17. Enter Key used to enter Prog Mode (Press
and hold for 5 seconds) and to validate the
settings programmed through the keypad.
18. ESC key used to escape from a specific
screen up to the main menu.
19. Lamp test key to check the LED’s and
LCD screen.
20. Green LED Indication: Power
21. Red LED Indication: Product Unavailable /
Manual Mode / Fault Condition
22. Auto / Manual mode selector switch
(Key version available as an option)
23. Padlocking facility
(Up to 3 padlocks of dia. 4 - 8mm)
24. Emergency manual operation shaft location
(Accessible only in manual mode)
25. Switch position indication window:
I (On switch I) O (Off) II (On switch II).
AUT Mode (Remote Control)
Imp. ≥60ms
maintened
order I
position I
order 0
position 0
order II
position II
Contactor logic
Impulse logic
STEP 7B
AUT Mode (Automatic Control)
STEP 7A
Ensure that the emergency handle is not
inserted in the product and turn the mode
selector to the AUT position.
LED “Power” Green: ON
LED Manuel/Default: OFF
STEP 7D
Dimensions in./mm.
Manual Operation
STEP 7C
AUT