socomec NETYS RT Series Manuals
1 pdf manual(s) socomec NETYS RT Series for free download (Document Types: Quick start manual)
socomec NETYS RT Series Quick start manual [PDF] (2 pages)
- Identifier: id-1423712
- Brand: socomec
- Device: socomec NETYS RT Series UPS
- Type: Quick start manual, PDF
- Key Aspects: FAQ Section for Common Queries, Component Longevity Optimization, Technical Data and Parameters
- UPD Date: 08.07.2026
- Source File: 1574732.pdf
- Pages: 2
- Description: Technical reference manual for the socomec NETYS RT Series.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
NETYS RT 5 - 1 1 k V A 3 sec 172 DRWNETRT-XX short Normal operation Normal drift SWITCHING ON AND BATTERY CHARGING Turn ON the Input switch on the back of the UPS module. The display is now active. Turn ON the battery switch on the back of the battery xtension module. The batteries are now charging, and will be fully charged in approximately 8 hours. PRESS - THE ON BUTTON UP TO BEEP The LCD will display DIAGNOSTIC MODE, it will be a few seconds before the UPS commences normal operation. The UPS can also be used with the batteries not fully charged, though if a power cut occurs backup time will be shorter. The UPS may also be turned on with no mains power, using only the batteries as a power supply. Be aware that if you do not press the on buttons for 3 seconds, the LCD will be active but with the UPS only on bypass mode and a yellow LED flashing. No battery backup is availible. STARTE UPS OG LADE BATTERIER På baksiden av UPS-kabinettet er det en inngangsbryter. Slå denne på, og skjermen blir aktiv. Slå på bryteren på baksiden av batterikabinettet. Batteriene begynner nå å lades. La UPSen stå på lading i minimum 8 timer for å lade batteriene helt opp. HOLD INNE PÅ-KNAPPEN TIL DU HØRER EN KORT PIPELYD LCD-skjermen vil vise “DIAGNOSTIC MODE”, som tar noen sekunder før UPS er i normal drift. UPSen kan brukes selv om batteriene ikke er helt oppladet, men det vil medføre kortere batteribackuptid ved strømbrudd. UPSen kan også slås på uten strømtilførsel, den bruker da de interne batteriene som strømkilde. Dersom du ikke holder inne startknappen i 3 sekunder, kan det virke som om UPSen er på. LCD-skjermen er aktiv, men UPSen er nå i bypass - gul LED lyser, og du vil ikke ha aktiv batteribackup. MIMIC PANEL A Display B Red symbol - fault C 2 colour LCD - Green is Normal, RED - is overload D Green LED lit - normal operation E Power-on, Enter and Buzzer override button F Scroll button - UP G Scroll button - DOWN H Off button I Green LED: Lit - Mains healthy, Flashing - Mains low but not lost L 3 colour LEDs: Green - Battery power, Yellow - Battery low, Red - replace battery M Yellow LED: Lit - Bypass mode, Flashing - Bypass voltage out of range ENGLISH NORWEGIAN Den komplette manualen ligger på vedlagte CD-plate. The full operating manual is on the CD ROM provided Installasjon av UPS må tilfredsstille nasjonale retningslinjer. The UPS installation must comply with relevant national regulations. BATTERY MODE The UPS automatically switches to battery mode when mains power fails. In this mode the Battery Mode LED indicator has a green light. Low battery level is indicated with a Yellow light in the battery symbol. Just before shutdown, when battery charge runs out fully, low battery charge is signalled via a rapid intermittent acoustic alarm. The UPS automatically returns to normal operating mode about two seconds after the mains power is restored. BATTERIDRIFT UPSen vil automatisk bytte fra normal- til batteridrift dersom strømtilførselen svikter. I batteridrift vil LED-lampen i batterisymbolet lyse grønt. Lavt batterinivå signaliseres ved et gult lys i samme symbol. Like før UPSen slå seg helt av fordi batteriet tømmes, vil du høre en lydalarm hvert sekund. UPSen vi automatisk returnere til normal drift etter to sekunder når strømtilførselen er normal igjen. FORKLARING AV PANEL A Skjerm B Rødt symbol lyser betyr feil på UPS C To farget LCD - Grønt betyr normalt, Rødt betyr overlast D Grønn LCD lyser betyr UPS i normal drift E Knapp for å slå på UPS, er også knapp for Enter eller slå av lyd F Velge menyer på LCD - skroller oppover G Velge menyer på LCD - skroller nedover H AV-knapp I Grønn LED: Lyser betyr strømtilførsel OK, blinker betyr lav men ikke borte L 3-farget LED: Grønt - UPS i batteridrift, Gul - lavt batterinivå, Rød - bytt batteri M Gul LED: Lyser - UPS i bypass, Blinker - I bypass, men dårlig strømkvalitet 110 DRWNETRT-XX H G F E A M I L D B C Battery mode Batteridrift Connect the UPS to the mains, load and battery. The electrical installation must be performed by qualified technicians. UPSen tilkobles nett, last og batteri. Dette skal utføres av autorisert elektriker.
Similar Manuals in the UPS Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
CyberPower BM100 |
BM100 (UPS ePDF Manual, #736R6F) |
2 | 1199 | 288 | 14-03-2026 | view all manuals | |
HP StoreOnce 2900 |
HP StoreOnce 2900 User Guide (Read me first), @6EL5MQ |
4 | 1337 | 335 | 25-05-2026 | view all manuals | |
Xmart OPTIMA T09 1K |
#XB84B7: OPTIMA T09 1K UPS Operation & user’s manual |
28 | 897 | 180 | 12-08-2026 | view all manuals | |
Tripp Lite OMNIVS800 |
PDF User Guide (@1GSW7O), Tripp Lite OMNIVS800 UPS (31-03-2026) |
28 | 0.68 Mb | 1111 | 223 | 31-03-2026 | view all manuals |
Atek Blazer Vista 400 VA |
#R8GF2T: Blazer Vista 400 VA UPS Operation & user’s manual |
12 | 346 | 77 | 17-06-2026 | view all manuals | |
WÄRTSILÄ JOVYSTAR COMPACT S BAX 5452 |
#4W4927: JOVYSTAR COMPACT S BAX 5452 UPS Operating manual |
217 | 82 | 19 | 02-05-2026 | view all manuals |