Solar Ajax Manuals

1 pdf manual(s) Solar Ajax for free download (Document Types: Quick start manual)

Solar Ajax Quick start manual [PDF] (2 pages)

  • Identifier: id-2061832
  • Brand: Solar
  • Device: Ajax Security System
  • Type: PDF
  • Key Aspects: Technical Support and Resource Links, Initial Startup Checklist, Warranty and Service Information
  • UPD Date: 01.05.2026
  • Source File: 2226025.pdf
  • Pages: 2
  • Description: Complete technical documentation for the Solar Ajax.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Solar Sikring MotionProtect Plus 1. FEATURES Wireless detector with additional microwave sensor Ajax MotionProtect is designated for human motion detection. It functions as a part of Ajax security system. 2. SPECIFICATIONS SPECIFICATION MEANING Sensor type Wireless Uses Indoors Movement detection distance Up to 12 m (39.4 ft) Sensitivity 3 levels adjustable (low, medium, high) Detecting elements Pyrosensor and microwave sensor (24GHz) Additional protection Microwave sensor to filter composite false alarms sources Detection angle 88.5° horizontal / 80° vertical Installation height suggested 2.4 m (7.9 ft) Pet ignoring option Weight up to 20 kg (44 lb), size up to 50 cm (19.7 in) Tamper protection Available Radio signal power 20 mW Radio-frequency range 868 or 915 MHz depending on the country of distribution Maximum distance between sensor and central unit 2000 m (6552 ft) (open area) Power supply CR123A battery Power supply voltage 3V Battery life Up to 5 years Operation temperatures range From 0°С (+32°F) to +50°С (+122°F) Operation humidity Up to 80% Dimensions 110х65x50 mm (4.33x2.55x1.96 in) Weight 96 g 3. COMPONENTS Motion detector, battery CR123A (pre-installed), manual, installation set 4. GETTING STARTED 4.1 Before installing the sensor, it is required to register it with the Ajax se- curity system. In order to register the sensor, it is necessary to switch the Ajax security system’s receiver to «Add Device» mode (the receiver’s man- ual explains how to accomplish it) and to put the switch «2» (PICTURE 4) on the sensor to the «ON» position. Sensor’s light must blink at the moment of switching on. The registration request is transmitted at the moment the sen- sor is switched on only! In case the registration was not successful, switch off the sensor, wait for 5 seconds and switch it on again. If the sensor’s light blinks constantly (each second during one minute), it means that the sensor is not registered. The light blinks in the same way if the sensor is deleted from the registration list. Non-registered sensor blinks also throughout 3 seconds during each activation. 4.2 Having registered the sensor successfully, select an appropriate location to install it. ATTENTION! Make sure that in the installation location sensor has a stable radio con- tact with the receiver! A maximum distance of 2000 m (6552 ft) between the sensor and the receiver is mentioned as a comparison with other devices. This distance was found as a result of open area tests. Connec- tion quality and distance between the sensor and the receiver can vary depending on installation location, walls, compartments, bridgings, as well as the thickness and constructional material. Signal coming through obstacles, loses power. For example, distance range between the sensor and receiver, divided with two reinforced concrete bearing walls, constitutes approximately 30 m (98.4 ft). Please note that moving the sensor even 10 cm (4 in), it is possible to improve the signal recep- tion considerably. Before installation, make sure to check the signal strength in the place where you intend to install the sensor! It is possible to launch a signal lev- el test on the receiver’s side. Test launching is described in the receiver’s manual. ATTENTION! Signal level test and detection zone test for sensors take some time to start. A certain period of time is necessary for the receiver to send a test request to the sensor, and for the sensor to send a test response. 5. INSTALLATION 5.1 The sensor must be installed in such a way that the intruder’s assumed entrance was perpendicular to the sensor’s lens axis. Make sure to check if the sensor is functioning at the point where it is going to be installed! (see paragraph 5.7) 5.2 In order to install the sensor, move the plastic fastening clip Smart- Bracket (PICTURE 1) alongside the frame and remove it. 5.3 Install the fastening clip SmartBracket on the wall with a help of the ex- pansion bolts and self-tapping screws included in the set (PICTURE 2). The height suggested for the sensor installation is 2.4 m (7.9 ft). Sensor installation height other than the height suggested 2.4 m (7.9 ft) re- duces sensor detection distance and can diminish the area protected. PICTURE 1. MotionProtect Plus detector and its SmartBracket SmartBracket is to be moved down and removed 5.4 Put the sensor on the SmartBracket. Once the sensor is fixed on the SmartBracket, its light must blink. It means that the tamper on the sensor is shut. In case the sensor does not blink, the tamper status must be checked at the receiver configuration software! PICTURE 2. SmartBracket wall installation scheme RECEIVER DETECTOR’S LIGHT DESCRIPTION 3 indication bars lights almost permanently, with short breaks each 1.5 seconds excellent signal 2 indication bars blinks 5 times per second medium signal 1 indication bar blinks twice per second low signal 0 bars short flashes each 1.5 seconds no signal Solar Plus Ajax MotionProtect Plus

Solar Ajax: Security System Category Related Instructions

GM01
Concox GM01
17.08.2026 14 pages

Importer: Przedsiębiorstwo Handlowo Usługowe FENIKS Cyprian Pawlaczyk ul. Słoneczna 110, Nowa Kuźnica, 42-350 Koziegłowy Polska - Poland NIP: 627-114-97-86 REGON: 240243739 www.elmic.pl, [email protected] USER MANUAL NAME: WIRELESS HOME ALARM MODEL: GM01 PLE Quick start guide for the Concox GM01 Security System. The manual highlights system setup, regulatory notices, service contacts, safety information.

HAM2007
Velleman HAM2007
17.03.2026 18 pages

HAM THREE- DRIE-D ALARME ALARM 3-STEL USER M GEBRU NOTICE MANUA BEDIEN M2007 -DIGIT ENTR DIGIT INBRA E D’INTRUSIO A DE 3 DÍGI LLIGER ALAR MANUAL IKERSHAND E D’EMPLOI AL DEL USUA NUNGSANLE RY ALARM + AAKALARM + ON 3 DIGITS ITOS + CONT RM + MAGNET DLEIDING Installation instructions for the Velleman HAM2007 Security System. The guide covers usage and shutdown procedures, operating conditions, specifications, safety.

TZ 170
SonicWALL TZ 170
24.05.2026 30 pages

Reference manual for the SonicWALL TZ 170 Security System. The document guides users through software updates, backup procedures, product maintenance.

B200 R65
Ecco B200 R65
21.07.2026 3 pages

Page 1 of 3 P/N 920-0695-00 (Rev B) 2018-02-20 Important! This unit is a safety device, and it must be connected to its own separate, fused power point to assure its continued operation should any other electrical accessory fail. Caution: When drilling into an Complete service manual for the Ecco B200 R65 Security System. It includes maintenance procedures and device instructions, repair references, warranty information.