Sony MVS-6530 Manuals

3 pdf manual(s) Sony MVS-6530 for free download (Document Types: Manual , Operation & user’s manual, Installation manual)

Sony MVS-6530 Manual  Main Page Preview

Manual  [PDF] (5 pages)

  • Updated: 14.08.2026

Document Preview & Text Transcription

Multi Format Switcher System MVS-6520 System MVS-6530 System MVS-3000A System MVS-3000 System (With ICP-series Control Panel) Supplement 2 [English] Software Version 1.22 Related Manual MVS-6520/6530/3000A/3000 System User’s Guide Software Version 1.10 and Later MVS-6520 MVS-6530 MVS-3000A MVS-3000 ICP-6520 ICP-6530 ICP-3000 ICP-3016 ICP-6511 MKS-6550 MKS-6570 SII-2 Table of Contents / Functions Newly Supported in Version 1.22 This Supplement describes the functions made available by the MVS-6520/6530/3000A/3000 system software upgrade. Table of Contents Functions Newly Supported in Version 1.22 .................................... SII-2 Frame Delay Function........................... SII-3 Delaying Unconverted Input Signals...... SII-3 Frame Synchronizer.............................. SII-3 Synchronizing Unsynchronized Input Signals.................................. SII-3 Functions Newly Supported in Version 1.22 The functions newly supported in MVS-6520/6530/ 3000A/3000 system version 1.22 are as follows. Functions relating to the switcher Classification Functions supported Menu No. See page User’s Guide Format converter 480i/59.94 and 576i/50 frame delay function support 7313.4 7332 SII-3 Chapter 17 Chapter 19 Frame synchronizer 7313.4 SII-3 Chapter 17 SII-3 Frame Delay Function / Frame Synchronizer Frame Delay Function The frame delay function using the format converter is now supported when the signal format is 480i/59.94 or 576i/50. Delaying Unconverted Input Signals When the signal format is 480i/59.94, 576i/50, 1080i/ 59.94, or 1080i/50, you can set the delay of unconverted input signals (frame delay function). To use the frame delay function, select the target input to set in the Engineering Setup >System >Format >Format Converter menu (7313.4), and select [Frame Delay] in the pop-up window. For details about the configuration procedure, see “Setting Conversion Formats” in Chapter 17. • You can set the delay amount in 1-frame units, up to eight frames. For details about setting the delay, see “Selecting the Input to which the Frame Delay Function Applies” in Chapter 19. • Use an input signal synchronized to the reference signal to obtain the same delay as that configured. • You can use the frame delay function as a frame synchronizer by setting the delay value to “1.” For details, see “Frame Synchronizer” (page SII-3). Frame Synchronizer The frame synchronizer function using the format converter is now supported. Synchronizing Unsynchronized Input Signals You can synchronize unsynchronized input signals using the format converter (frame synchronizer). The following two methods are available. Using an up-converter When the signal format is set to1080i/59.94 or 1080i/50, the input signal can be synchronized by the up-converter. To use the frame synchronizer, select the target input to set in the Engineering Setup >System >Format >Format Converter menu (7313.4), and select [480i/59.94 (with FS)] or [576i/50 (with FS)] in the pop-up window. For details about the configuration procedure, see “Setting Conversion Formats” in Chapter 17. • You can synchronize the input signal to the reference signal within a range of ±0.5 frames with respect to the reference signal. • If the frame synchronizer is used, the up-converter introduces a delay of two frames with respect to the reference signal. Using the frame delay function When the signal format is set to 480i/59.94, 576i/50, 1080i/59.94, or 1080i/50, you can use the frame delay function as a frame synchronizer by setting the delay value to “1.” Notes Notes

Document Preview & Text Transcription

USO RESTRITO Multi Format Switcher System MVS-6520 System MVS-6530 System MVS-3000A System MVS-3000 System (With ICP-series Control Panel) MVS-6520 MVS-6530 MVS-3000A MVS-3000 ICP-6520 ICP-6530 ICP-3000 ICP-3016 ICP-6511 MKS-6550 MKS-6570 User’s Guide [English] Software Version 1.10 and Later 1st Edition (Revised 1) USO RESTRITO NOTICE TO USERS © 2012, 2013 Sony Corporation. All rights reserved. This manual or the software described herein, in whole or in part, may not be reproduced, translated or reduced to any machine readable form without prior written approval from Sony Corporation. SONY CORPORATION PROVIDES NO WARRANTY WITH REGARD TO THIS MANUAL, THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN AND HEREBY EXPRESSLY DISCLAIMS ANY IMPLIED WARRANTIES OF MERCHANTABILITY OR FITNESS FOR ANY PARTICULAR PURPOSE WITH REGARD TO THIS MANUAL, THE SOFTWARE OR SUCH OTHER INFORMATION. IN NO EVENT SHALL SONY CORPORATION BE LIABLE FOR ANY INCIDENTAL, CONSEQUENTIAL OR SPECIAL DAMAGES, WHETHER BASED ON TORT, CONTRACT, OR OTHERWISE, ARISING OUT OF OR IN CONNECTION WITH THIS MANUAL, THE SOFTWARE OR OTHER INFORMATION CONTAINED HEREIN OR THE USE THEREOF. Sony Corporation reserves the right to make any modification to this manual or the information contained herein at any time without notice. The software described herein may also be governed by the terms of a separate user license agreement. USO RESTRITO Classification Functions supported Menu No. See page System Control panel type setting 7316 p. 317 Serial tally Source address default setting 7367.1 p. 377 Functions Newly Supported in Version 1.10 The functions newly supported in the MVS-6520/6530 system version 1.10 are as follows. Functions relating to operability Classification Functions supported Menu No. See page Transitions AUX mix transition On/Off menu operation 3232 p. 151 AUX mix transition 7142.2 p. 281, macro event 7142.3 p. 287 support AUX mix transition 2311 p. 151, Bus CCR interlock 7333.12 p. 355, 7335.3 p. 357 Multi Viewer 16-split window setting 7333.9 p. 353 Functions relating to the system Classification Functions supported Menu No. See page Panels ICP-3000 control panel connection – p. 28 ICP-3016 control panel connection – p. 28 System Manager Operation from System Manager 3211 p. 150 Functions relating to setup Classification Functions supported Menu No. See page System Control panel type setting 7316 p. 317 Serial tally Source address default setting 7367.1 p. 377 The functions newly supported in the MVS-3000 system version 1.10 are as follows. Functions relating to operability Functions relating to the system Classification Functions supported Menu No. See page Panels ICP-3016 control panel connection – p. 28 ICP-6520 control panel connection – p. 27 ICP-6530 control panel connection – p. 27 ICP-3000 control panel and ICP- 6511 menu panel connection – p. 28, p. 42 DME MVE-8000A/9000 multi format DME processor connection 41XX 42XX 734X p. 157, p. 363 DCU MKS-8700/2700 device control unit connection 735X p. 366 System Manager Operation from System Manager 3211 p. 150 Functions relating to setup Classification Functions supported Menu No. See page Transitions AUX mix transitions 3232 7333.12 p. 78, p. 151, p. 355 Multi Viewer 16-split window setting 7333.9 p. 353 3 USO RESTRITO 4 Table of Contents Table of Contents Chapter 1 Overview Introduction ............................................... 16 Features ..................................................... 17 Basic Video Processing ............................ 18 Transitions................................................... 18 Keys ............................................................ 19 Wipes .......................................................... 20 DME Wipes ................................................ 20 Frame Memory ............................................ 20 Color Backgrounds ..................................... 20 Copy and Swap ........................................... 20 Color Corrector ........................................... 21 Side Flags .................................................... 21 Creation of Special Effects and Management of Data and Operations .......................................... 21 Digital Multi Effects (DME) ....................... 21 Controlling External Devices ...................... 22 Keyframes ................................................... 22 Snapshots .................................................... 22 Utilities ........................................................ 22 Shotboxes .................................................... 22 Macros ........................................................ 22 File Operations. ........................................... 23 Setup .......................................................... 23 System Configuration ............................... 24 System Configuration Example ................... 24 Connection Example ................................... 25 ICP-3016 Control Panel Configuration ........ 28 Cross-Point Control Block (ICP-6520/6530) ................................ 29 Cross-Point Control Block (ICP-3000/3016) ................................ 31 Transition Control Block ............................. 34 Device Control Block .................................. 38 Flexi Pad ..................................................... 40 Menu Panel.................................................. 42 Names and Functions of Parts of the Menu .................................................... 43 Overview ..................................................... 43 Top Menu List ............................................. 43 Menu Screen................................................ 43 Top Menu Window ..................................... 46 Numeric Keypad Window ........................... 47 Keyboard Window ...................................... 48 Color Palette Window ................................. 49 Basic Menu Operations ............................. 49 Recalling Menus .......................................... 49 Selecting Menus .......................................... 50 Selecting List Items ..................................... 50 Setting Parameters ....................................... 50 Returning Parameters to Default Values ....... 51 Operation with a Mouse ................................ 51 Using Shortcut Menus ................................. 51 Switching between the Main Menu Site and Subsidiary Menu Site ................... 52 Power Supply and Connectors ................. 53 MVS-6520/6530/3000A/3000 Multi Format Switcher Processor ................. 53 ICP-6520/6530/3000/3016 Control Panel .................................................. 56 ICP-6511 Menu Panel ................................. 57 Chapter 2 Names and Functions of Parts Names and Functions of Parts of the Control Panel ...................................... 26 ICP-6520 Control Panel Configuration ...... 27 ICP-6530 Control Panel Configuration ...... 27 ICP-3000 Control Panel Configuration ...... 28 Chapter 3 Signal Selection and Transitions Video Processing Flow .............................. 59 Signal Selection ......................................... 60 Basics of Signal Selection ........................... 60 Bus Selection ............................................... 60 Signal Assignment and Selection ................. 61

Document Preview & Text Transcription

2M/E MULTI FORMAT SWITCHER PROCESSOR MVS-6520 MVS-3000 3M/E MULTI FORMAT SWITCHER PROCESSOR MVS-6530 FORMAT CONVERTER BOARD MKS-6550 DIGITAL MULTI EFFECT BOARD MKS-6570 INSTALLATION MANUAL 1st Edition MVS-6520 ! 警告 このマニュアルは,サービス専用です。 お客様が,このマニュアルに記載された設置や保守,点検,修理などを行うと感電や火災, 人身事故につながることがあります。 危険をさけるため,サービストレーニングを受けた技術者のみご使用ください。 ! WARNING This manual is intended for qualifi ed service personnel only. To reduce the risk of electric shock, fi re or injury, do not perform any servicing other than that contained in the operating instructions unless you are qualifi ed to do so. Refer all servicing to qualifi ed service personnel. ! WARNUNG Die Anleitung ist nur für qualifi ziertes Fachpersonal bestimmt. Alle Wartungsarbeiten dürfen nur von qualifi ziertem Fachpersonal ausgeführt werden. Um die Gefahr eines elektrischen Schlages, Feuergefahr und Verletzungen zu vermeiden, sind bei Wartungsarbeiten strikt die Angaben in der Anleitung zu befolgen. Andere als die angegeben Wartungsarbeiten dürfen nur von Personen ausgeführt werden, die eine spezielle Befähigung dazu besitzen. ! AVERTISSEMENT Ce manual est destiné uniquement aux personnes compétentes en charge de l’entretien. Afi n de réduire les risques de décharge électrique, d’incendie ou de blessure n’effectuer que les réparations indiquées dans le mode d’emploi à moins d’être qualifi é pour en effectuer d’autres. Pour toute réparation faire appel à une personne compétente uniquement. 安全のために,周辺機器を接続する際は,過大電圧を持 つ可能性があるコネクターを以下のポートに接続しない でください。 : MVS コネクター : UTIL (SW) コネクター : UTIL (SCU) コネクター : UTIL (FM) コネクター 上記のポートについては本書の指示に従ってください。 For safety, do not connect the connector for periph- eral device wiring that might have excessive volt- age to the following ports. : MVS connector : UTIL (SW) connector : UTIL (SCU) connector : UTIL (FM) connector Follow the instructions for the above ports. For kundene i Norge Dette utstyret kan kobles til et IT-strømfordelingssystem. When installing the installation space must be secured in consideration of the ventilation and service operation. . Do not block the ventilation slots at the left side and right side panels, and vents of the fans. . Leave a space around the unit for ventilation. . Leave more than 20 cm of space in the rear of the unit to secure the operation area. When the unit is installed on the desk or the like, leave at least 10 cm of space in the front, left and right sides. Leaving 4 cm or more of space above the unit is recommended for service operation. 設置時には,通気やサービス性を考慮して設置スペー スを確保してください。 . ファンの排気部や通気孔(左側面および右側面)をふ さがない。 . 通気のために,セット周辺に空間をあける。 . 作業エリアを確保するため,セット後方は,20 cm 以 上の空間をあける。 机上などの平面に設置する場合は,前面および左右側 面は10 cm 以上の空間をそれぞれ確保してください。 ただし,セット上部はサービス性を考慮し4 cm 以上の 空間を確保することを推奨します。 1 (E) MVS-6520 Table of Contents Manual Structure Purpose of this manual ............................................................ 2 (E) Related manuals ...................................................................... 2 (E) Trademarks .............................................................................. 2 (E) 1. Installation 1-1. Operating Environment .............................................1-1 (E) 1-2. Power Supply ............................................................1-1 (E) 1-2-1. Power Specifications........................................1-1 (E) 1-2-2. Power Cord ......................................................1-1 (E) 1-3. Installation Space (External Dimensions) .................1-2 (E) 1-4. Installing the Optional Board ....................................1-5 (E) 1-4-1. Installing the Plug-in Boards ...........................1-5 (E) 1-5. Rack Mounting ..........................................................1-7 (E) 1-6. Matching Connectors and Cables ..............................1-9 (E) 1-7. Input/Output Signals of Connectors ........................1-10 (E) 1-8. Description of On-board Switches, LEDs and Connectors..............................................1-12 (E) 1-8-1. MVS-6520/6530/3000 ...................................1-12 (E) 1-8-2. DVP-55 Board (MKS-6570) ..........................1-22 (E) 1-8-3. FC-114 Board (MKS-6550) ...........................1-24 (E) 1-9. System Connection ..................................................1-26 (E) 1-9-1. Connection Example of the MVS-6520/6530 System ..........................1-26 (E) 1-9-2. Connection Example of the MVS-3000 System ...................................1-27 (E) 2. Service Overview 2-1. Troubleshooting.........................................................2-1 (E) 2-2. Periodic Inspection and Maintenance .......................2-1 (E) 2-2-1. Periodic Inspection ..........................................2-1 (E) 2-2-2. Cleaning ...........................................................2-2 (E) 2-3. About the Data Backup Capacitor .............................2-3 (E) 2 (E) MVS-6520 Manual Structure Purpose of this manual This manual is the Installation Manual of following models. . 2M/E Multi Format Switcher Processor MVS-6520/3000 . 3M/E Multi Format Switcher Processor MVS-6530 This manual is intended for use by trained system and service engineers, and provides the information that is required to install (operating environment, installation space, connection information, etc.). Related manuals Besides this Installation Manual, the following manuals are prepared for this unit. . Operation Manual (Supplied with this unit.) This manual describes the outline and specifi cation of this unit. . User’s Guide (supplied with this unit) This manual describes the information required for the actual application and op- eration of this unit. . Startup Guide (supplied with this unit) This manual describes the information intended for the user who performs applica- tion and operation of this unit for the fi rst time. . Maintenance Manual (Available on request) This manual describes the maintenance and service information (service overview, detailed parts list, block diagrams, board layouts, schematic diagrams, etc.) for this unit. Trademarks Trademark and registered trademark used in this manual is follows. . Ethernet is a registered trademark of Xerox Corporation. Other system names, product names, and company names appearing in this manual are trademarks or registered trademarks of their respective holders.