STERIS 4085 General Surgical Table
1
-
TABLE OF CONTENTS
2
-
A WORD FROM STERIS CORPORATION
4
-
Table of Contents
7
-
WARNING – PERSONAL INJURY HAZARD:
12
-
WARNING – DISPOSAL HAZARD:
14
-
1.1 Symbols on Table
15
-
1.2 Symbols on Hand
16
-
Tabletop Down (Height Up; Lower)
17
-
Floor Locks Unlocked (Orange).
18
-
Important User Information
19
-
Install leg section as follows:
31
-
Figure 3-4. Connect Panel
32
-
Figure 3-6. Install Head Section
33
-
4.1 Operating Table
34
-
4.2 Hand Control
36
-
Figure 4-3. STERIS 4085 General Surgical Table
37
-
4.2.2 Hand Control LCD
39
-
4.5.1 Backup (Override)
41
-
4.5.3 Return Backup Control
43
-
Figure 4-7. Leg Section Removal
44
-
4.8 X-Ray Top
45
-
The standard STERIS permanently attac
46
-
5.1 Read Before
47
-
5.2 Cleaning Table
48
-
5.2.2 After Each Usage
49
-
Turn hand control OFF and clean as follows:
50
-
Maintenance procedures descri
53
-
5.7 Replacement Parts
54
-
5.9 LEVEL Check
56
-
Table 6-2. Troubleshooting Chart (LCD Message)
59
-
EC Authorized Representative
63
-
TABLE OF CONTENTS (CONT’D)
65
-
LIST OF FIGURES
67
-
LIST OF FIGURES (CONT’D)
68
-
LIST OF TABLES
69
-
Section 1: Safety Precautions
70
-
WARNING – ELECTRIC SHOCK HAZARD:
72
-
CAUTION – POSSIBLE EQUIPMENT DAMAGE (CONT’D):
73
-
2.1 TERMS AND DEFINITIONS
74
-
2.3 SPECIAL TOOLS/MATERIALS
75
-
Frequency Rating of Unit
76
-
Move Tabletop into Trendelenburg
77
-
Maintenance Notification (Blue).
78
-
FLEX and REFLEX functions are NOT available
81
-
Other fuses internal to the power supply are as
84
-
control pass through the table control board at
85
-
5. 230 V Power Supply Variation:
86
-
In addition to the routine maintenance, regularly
87
-
• Container of clean water.
89
-
4.3.2 After Each Usage
90
-
2. Check table casters and floor locks for any
91
-
Batteries require recharging on a periodic basis
92
-
Figure 4-2. Install/Remove Battery Fuse (Typical)
93
-
4.9 FLOOR LOCK PROCEDURES
94
-
Table 5-1. Troubleshooting Guide
97
-
6. Table does not function on facility
98
-
12. Hand Control displays SENSOR
99
-
19. Table has longitudial mechanical
100
-
25. Only tabletop slide function
101
-
5.2 ELECTRICAL TROUBLESHOOTING
102
-
Important: Unless otherwise specified, all STERIS
103
-
Figure 6-1. Table Sensor Calibration
104
-
22. Display shows BACK DOWN MAX. Lower back
105
-
Figure 6-2. Table Sensor Calibration
106
-
6.4 ACCESSORY ATTACHMENTS
107
-
Figure 6-5. Note Direction of Lash
108
-
Figure 6-6. Articulation Adjustment Screws
109
-
This section provides procedures for removing/
110
-
Precautions must be taken when servicing the
111
-
Figure 7-2. Table Column Bottom Cover Screws
112
-
Figure 7-5. Ensure Base Cover Sits Flush on
113
-
11. Secure lower cover to base using four existing
114
-
6. Carefully slide power supply away from table
115
-
7.10 CASTER REPLACEMENT
116
-
3. Turn Main Power Switch to OFF and remove
117
-
Figure 7-21. Table Column Plastic Cap
118
-
Figure 7-24. Replacing CPU Board
119
-
8. Unscrew Trendelenburg cylinder rod.
120
-
Figure 7-28. Disconnect Hydraulic Lines From
121
-
7.20.4 Leg Section
122
-
7.22 KIDNEY CYLINDER REPLACEMENT
123
-
10. Loosen leg cylinder bottom locking screw (see
124
-
Figure 7-41. Leg Switch Replacement
125
-
5. Remove Trendelenburg sensor and disconnect
126
-
4. Remove seat plastic cover as follows:
127
-
7.33 BACK SECTION HYDRAULIC
128
-
2. Turn Main Power Switch to OFF and remove
129
-
Example 1. How To Use IPB Page (Typical)
133
-
List of Illustrations and Tables
134
-
Table 2. Quick Reference Parts (Hydraulics)
136
-
Table 3. Quick Reference Parts (Labels)
137
-
Table 4. Quick Reference Hardware Listing
138
-
Socket Head Cap Screw, M4 x 25 SS
139
-
Hydraulic Oil Pack
140
-
4085 Surgical Table Plastic Shroud and
143
-
Figure 2. 4085 Surgical Tabletop (1 of 3)
144
-
Figure 2. 4085 Surgical Tabletop (2 of 3)
145
-
Figure 2. 4085 Surgical Tabletop (3 of 3)
146
-
4085 Surgical Tabletop ................
147
-
4085 Surgical Tabletop Slide and Sectio
153
-
4085 Table Base Assemby With Plastic Sh
158
-
Figure 5. 4085 Surgical Table Hydraulics (1 of 2 )
161
-
Figure 5. 4085 Surgical Table Hydraulics (2 of 2)
162
-
Figure 6. 4085 Surgical Table Electrical Cables
164
-
Cable Position To
165
-
Figure 7. 4085 Surgical Table Headrest Assembly
166
-
4085 Surgical Table Headre
167
-
Figure 8. 4085 Surgical Table Leg Section Assembly
168
-
LEG SECT ASSY Cmax/4085/5085 General
169
-
Live Document, Historical Table