SUNFLEX SWISH ELEMENTS BAY KIT Manuals

1 pdf manual(s) SUNFLEX SWISH ELEMENTS BAY KIT for free download (Document Types: Fitting instructions)

Document Preview & Text Transcription

6454L/ISS2 1 1 1 3 1 5 2 5 4 8 3 6 2 7 3 8 3 2 5 5 4 Tools required Fitting Instructions Please keep for future reference 6139L/ISS1 Should any component be missing, please call the Customer Care Department on 0330 005 2233. Pack Content Please read these instructions carefully and check the contents of the pack before attempting to assemble and f x this product. Safety Recommendation Only use a Step Ladder to install this product. DO NOT over reach. Always move the Step Ladder so that you are in a safe working position. DO NOT hold or lean on the pole to support your weight. We recommend you use two people for installation of larger poles. Take care when using power tools, use of a Residual Current Device (RCD) is recommended. Always use eye protection when drilling. Beware of hidden pipe runs and cables. No liability will be accepted for damage or injury caused by incorrectly installed or assembled product. PLEASE KEEP OUT OF THE REACH OF YOUNG CHILDREN. SMALL PARTS - CHOKING HAZARD PLEASE KEEP THESE INSTRUCTIONS AND THE BATCH CODE ON THE PACKAGING FOR FUTURE REFERENCE IN CASE OF ANY QUERIES SWISH DESIGN STUDIO BAY KIT Bay Length Parts 300cm 400cm 500cm 1 Pole 4 4 4 2 Bracket 3 3 2 3 Pass Over Bracket 4 4 4 4 Standard Collar 2 2 2 5 Solid Ring 4 4 4 6 Pass Over Ring 26 36 46 7 Joiner 1 1 1 8 Bay Corner 2 2 2 3 6 5 2 3 1 3 2 4 1 3 2 6 6 1 5 stud drawing.AI 3 01/04/2014 09:19:22OR 3 6 5 2 3 1 3 2 4 1 3 2 6 6 1 5 7 { SWISH ELEMENTS BAY KIT Bay Length 400cm 1 Corner Joint 2 2 End Brackets 3 3 Passing Brackets 4 4 Pass Over Rings 36 5 Solid Rings 4 6 Pole 3 7 Finial 2 Sunfl ex, Keys Park Road, Hednesford, Cannock, WS12 2FR • tel: +44 (0)330 005 2233 • fax: +44(0) 1543 279505 • email: enquiries@sunfl ex.co.uk • web: www.sunfl ex.co.uk 17 Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 16 19 2.95 2.95 d1+d2+d1=Pole Length Approx. 10cm d2 (distance between end brackets) Approx. 10cm d1 d1 24 23 2.95 18 20 22 21 Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 15 Sunfl ex , Keys Park Road, Hednesford, Cannock, WS12 2FR • tel: +44 (0)330 005 2233 • fax: +44(0) 1543 279505 • email: enquiries@sunfl ex.co.uk • web: www.sunfl ex.co.uk Preparing the curtain (f g.17) 1. Leave the solid rings aside, slide the pass over rings and 1 solid rings onto the pole, approximately 1 ring per 100mm of pole, ensuring that 1 solid ring goes on last. 2. When using a centre bracket an equal number of rings will need to be used either side of the bracket. Fitting the Bay Corner 1. Adjust the bay corner into the desired angle by loosening the segment screws. Once in the desired positon re-secure the screws. (f g.15) 2. Slide the poles onto the plastic bung ends of the bay corners. (f g.16) Bay corners should always be supported by two pass over brackets. Fixing the collar (f g.19) 1. Position one solid ring between the bracket and the collar. 2. Push the collar onto the end of the pole. 3. Tighten the grub screw on the collar. Fixing the fi nial 1. If the collar is already installed on the pole, unscrew the grub screw and remove the collar. We do not recommend installing the f nial while the collar is f tted as it could scratch the pole. (f g.20) 2. Screw the f nial on the cup end of the collar. Please note that different design are available through the range. (f g.21) 3. Push the f nial onto the end of the pole. (f g.22) 4. Tighten the grub screw on the collar. Installing the curtain 1. Equally space curtain hooks along curtain header, you will require one hook for every ring. (f g.23) 2. Place hooks through the eyelet on the ring. (f g.23) 3. Test the installation by drawing the curtains across the pole. (f g.24) Fixing the pole (f g. 18) 1. Loosen the grub screw on the bracket. 2. Place pole in bracket. 3. Tighten the grub screw until the pole does not slide in the bracket. Fitting the Bay Corner 1. Adjust the bay corner into the desired angle by loosening the segment screw. Once in the desired positon re-secure the screw. (f g.15) 90˚ 45˚ 180˚ MIN 10mm gap W W Z Z 90˚ 45˚ 180˚ MIN 10mm gap W W Z Z 90˚ 45˚ 180˚ MIN 10mm gap W W Z Z Fixing the fi nial (f g.19) 1. Place one of the full rings on the pole after the bracket. 2. Slide the f nial onto the pole and tighten the grub screw until the f nial is secure. For Stud fi nials (f g.20) 1. Place one of the full rings on the pole after the bracket. 2. Push the f nial onto the pole until it is secure. 19 20 Installing the curtain 1. Equally space curtain hooks along curtain header, you will require one hook for every ring. (f g.21) 2. Place hooks through the eyelet on the ring. (f g.21) 3. Test the installation by drawing the curtains across the pole. (f g.22) 21 d1+d2+d1=Pole Length Approx. 10cm d2 (distance between end brackets) Approx. 10cm d1 d1 22 2 Z = 4cm minimum Z Z 10cm W W 3 1 Bend Bend 3 2 2 1 x a c b y a+b+c= size of bay a c b x y a+b+c= size of bay a c b e d x y a+b+c+d+e= size of bay 2a 2b 10cm 10cm 10cm z z w w z z w w 3 2 Bend 3 2 Bend z z w w 3 2 Bend Wall Installation Ceiling Installation 2c (applicable only when using top f x brackets sold separately) 2 Fitting Recommendation We recommend for better support to f t the pole to a secure wooden batten which is larger than the width of the backplate. (f g.1) If you are unsure if the product is suitable please ask advice from a professional builder or your DIY store. Measuring the Window (f g.2a,2b,2c) Straight lengths over 180cm will require an centre support bracket. Should you wish to dress your curtains outside of the bay recess, this is possible by reverse bending 2 extra corner joints and installing extra brackets (both sold separately). You will need to add x+y into your pole calculations and the minimum length for x or y is 10cm. Calculate the position of the pass over brackets at W and Z by laying the bay pole parts out on the f oor of your bay window (f g.2b), ensuring that the brackets are at the desired projection (see step 5 of the “Wall Fixing the Bracket” section). Calculate the bracket position so that the centre of the bracket is as near as possible to the outer metal edges of the bay corner. You will need to bend the bay corner to the correct angle, see “Fitting the Bay Corner”. Please Note that for reversed corners the centre of the bracket has to be at least 4cm from the edge of the wall. Calculate the end bracket so its centre is around 10cm for the desired end of the pole. DO NOT CUT THE POLES! The pass over brackets should support the joint between the bend and the pole. Mark the pole centre line on the wall and then mark the positions of the brackets on the wall using f g.2c below as a guide. 3 2 1 2 3 3 1 Bend Bend Bend Bend 3 2 2 Ceiling Installation (applicable only when using top f x brackets sold separately) = = = = Note - 1 may be made of two lengths of poles which will require a centre joint supported by a centre bracket. 3 2 1 2 3 3 1 Bend Bend Bend Bend 3 2 2 Wall Installation 10 13 14 12 = = 11 2.95 3 2.95 4 2.95 5 6 2.95 Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 8b Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 9 7 2.95 Hole offset Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 135° 8a 3 Note: Use the correct wall plugs and screws for the type of wall or ceilling to which you are mounting your pole. If you are unsure please consult your local builders merchant or DIY store. Wall Fixing the Bracket 1. Mark the top hole position for each bracket offset by 2.95cm from the pole centre line previously marked. (f g.3) 2. Use the bracket as a template to mark the second hole position onto the wall. (f g.4) 3. Drill holes and f t the correct plugs if f xing on masonry wall. 4. Fix the bracket using the correct screws. (f g.5) 5. The bracket can be adjusted in projection by unscrewing the inner screw. Once in the desired position, lock in place by tightening the inner screw. (f g.6) Ceiling Fixing the Bracket (sold separately) 1. The bracket can be adjusted to 3 positions by unscrewing the inner screw completly and tightening it back in the next avail- able position. (f g.7) 2. Mark the front hole position for each bracket offset from the pole centre line previously marked (f g.8a) as per table. 3. Use the bracket as a template to mark the second hole position onto the ceiling. (f g.8b) 4. Drill holes and f t the correct plugs if f xing on masonry ceiling. 5. Fix the bracket using the correct screws. (f g.9) Cutting the pole 1. Starting in the middle of the window (f g.10), build the pole outwards cutting the poles to length as required. Calculate each length of pole by measuring the distance between bracket centres, add 4cm to the poles connecting to a bend, add 10cm to the poles connecting to a f nial. 2. Mask area to be cut to avoid damaging pole. (f g.11) 3. When using two poles cut equal lengths from each pole. (f g.12) 4. File sharp edges to avoid injury or damage to other components. (f g.13) Joining poles (f g.14) 1. Join poles if required by sliding a joining piece into the uncut end of a pole. 2. Slide the second pole onto the joining piece taking care to push equal lengths of the joiner into each pole. 3. Always join the uncut ends of the pole. 4. Pole joints should always be at the half way point of the installation length and supported with a bracket. Pole zize Hole offset 19 2.9cm 28 2.1cm 35 1.1cm Calculate the position of the pass over brackets by laying the bay pole parts out on the f oor of your bay window (f g.2b), ensuring that the brackets are at the desired projection (see step 5 of the “Wall Fixing the Bracket” section). Calculate the position of the pass over bracket so its center is at least 4cm from the edge of the corner bend. You will need to bend the bay corner to the correct angle, see “Fitting the Bay Corner”. Calculate the position of the end bracket so its center is around 10cm from the edge of the window. DO NOT CUT THE POLES! Mark the pole centre line on the wall and then mark the positions of the brackets on the wall using f g.2c below as a guide. Bend Bend 2 1 2 Bend Bend 2 1 2 4 4 10 x a c b y a+b+c= size of bay a c b x y a+b+c= size of bay a c b e d x y a+b+c+d+e= size of bay 2a 2b z w 10cm 10cm 10cm 10cm z w z w 10cm 10cm Wall Installation Ceiling Installation (applicable only when using top f x brackets sold separately) 2c Should you wish to dress your curtains outside of the bay recess, this is possible by reverse bending 2 extra corner joints (from a different range, 4 if you wish to have all similar corner bend) and installing extra brackets (both sold separately). You will need to add x+y into your pole calculations and the minimum length for x or y is 10cm. 3 Z = 4cm minimum Z Z 10cm W W 3 1 Bend Bend 3 2 2 1 x a c b y a+b+c= size of bay a c b x y a+b+c= size of bay a c b e d x y a+b+c+d+e= size of bay 2a 2b 10cm 10cm 10cm z z w w z z w w 3 2 Bend 3 2 Bend z z w w 3 2 Bend Wall Installation Ceiling Installation 2c (applicable only when using top f x brackets sold separately) 2 Fitting Recommendation We recommend for better support to f t the pole to a secure wooden batten which is larger than the width of the backplate. (f g.1) If you are unsure if the product is suitable please ask advice from a professional builder or your DIY store. Measuring the Window (f g.2a,2b,2c) Straight lengths over 180cm will require an centre support bracket. Should you wish to dress your curtains outside of the bay recess, this is possible by reverse bending 2 extra corner joints and installing extra brackets (both sold separately). You will need to add x+y into your pole calculations and the minimum length for x or y is 10cm. Calculate the position of the pass over brackets at W and Z by laying the bay pole parts out on the f oor of your bay window (f g.2b), ensuring that the brackets are at the desired projection (see step 5 of the “Wall Fixing the Bracket” section). Calculate the bracket position so that the centre of the bracket is as near as possible to the outer metal edges of the bay corner. You will need to bend the bay corner to the correct angle, see “Fitting the Bay Corner”. Please Note that for reversed corners the centre of the bracket has to be at least 4cm from the edge of the wall. Calculate the end bracket so its centre is around 10cm for the desired end of the pole. DO NOT CUT THE POLES! The pass over brackets should support the joint between the bend and the pole. Mark the pole centre line on the wall and then mark the positions of the brackets on the wall using f g.2c below as a guide. 3 2 1 2 3 3 1 Bend Bend Bend Bend 3 2 2 Ceiling Installation (applicable only when using top f x brackets sold separately) = = = = Note - 1 may be made of two lengths of poles which will require a centre joint supported by a centre bracket. 3 2 1 2 3 3 1 Bend Bend Bend Bend 3 2 2 Wall Installation 10 13 14 12 = = 11 2.95 3 2.95 4 2.95 5 6 2.95 Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 8b Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 90° 135° 180° 9 7 2.95 Hole offset Distance between bracket centers d1 Distance between bracket centers Length of end pole = d1 + 147.5mm 135° 8a 3 Note: Use the correct wall plugs and screws for the type of wall or ceilling to which you are mounting your pole. If you are unsure please consult your local builders merchant or DIY store. Wall Fixing the Bracket 1. Mark the top hole position for each bracket offset by 2.95cm from the pole centre line previously marked. (f g.3) 2. Use the bracket as a template to mark the second hole position onto the wall. (f g.4) 3. Drill holes and f t the correct plugs if f xing on masonry wall. 4. Fix the bracket using the correct screws. (f g.5) 5. The bracket can be adjusted in projection by unscrewing the inner screw. Once in the desired position, lock in place by tightening the inner screw. (f g.6) Ceiling Fixing the Bracket (sold separately) 1. The bracket can be adjusted to 3 positions by unscrewing the inner screw completly and tightening it back in the next avail- able position. (f g.7) 2. Mark the front hole position for each bracket offset from the pole centre line previously marked (f g.8a) as per table. 3. Use the bracket as a template to mark the second hole position onto the ceiling. (f g.8b) 4. Drill holes and f t the correct plugs if f xing on masonry ceiling. 5. Fix the bracket using the correct screws. (f g.9) Cutting the pole 1. Starting in the middle of the window (f g.10), build the pole outwards cutting the poles to length as required. Calculate each length of pole by measuring the distance between bracket centres, add 4cm to the poles connecting to a bend, add 10cm to the poles connecting to a f nial. 2. Mask area to be cut to avoid damaging pole. (f g.11) 3. When using two poles cut equal lengths from each pole. (f g.12) 4. File sharp edges to avoid injury or damage to other components. (f g.13) Joining poles (f g.14) 1. Join poles if required by sliding a joining piece into the uncut end of a pole. 2. Slide the second pole onto the joining piece taking care to push equal lengths of the joiner into each pole. 3. Always join the uncut ends of the pole. 4. Pole joints should always be at the half way point of the installation length and supported with a bracket. Pole zize Hole offset 19 2.9cm 28 2.1cm 35 1.1cm Bend Bend 2 1 2 Bend Bend 2 1 2 4 Bend Bend 2 1 2 Bend Bend 2 1 2 Wall Fix Ceiling Installation (applicable only when using top f x brackets sold separatly)