System Sensor RTS451 Manuals

2 pdf manual(s) System Sensor RTS451 for free download (Document Types: Installation and maintenance instructions)

Document Preview & Text Transcription

D440-01-00 1 I56-0469-010 NOTICE: This manual shall be left with the owner/user of this equipment. NOTE: A test coil is required only for use with DH400/ DH500 models. For DH400 models order part # COIL400. For DH500 models order part # COIL. General Information System Sensor’s RTS451 is an automatic fire detector acces- sory designed to test a remotely located detector. Consult detector installation instructions for additional information. The National Fire Protection Association has published codes, standards, and recommended practices for the in- stallation and use of the above product. It is recommended that the installer be familiar with these requirements, with local codes, and any special requirements of the local au- thority having jurisdiction. RTS451 Contents 1 RTS451 remote test station 1 #4 screw for mounting bracket 1 screw pack (2 mounting screws) 1 M02-04 test magnet Wiring of RTS451 Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTS451 mounts to a single gang box (21/2” minimum depth), or directly to the wall or ceiling. See Figure 2 for wiring diagram of RTS451 with DH100ACDC Duct Smoke Detector. In Canadian applications, the RTS451 is intended to be lo- cated in the same room as the smoke detector and within 60 feet of the unit. Specifications Dimensions: 4.6˝ H × 2.75˝ W × 1.5˝ D Weight: .11 lbs. Power Requirements Alarm LED: 2.8 – 32 VDC, 7.5 mA max. Total Current: 105 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 sec. max. Temperature: –10°C to 60°C (14°F to 140°F) Humidity: 95% RH Non-condensing ALARM RESET M02-04 TEST MAGNET LOCATIONS Figure 1. RTS451 Remote Test Station: RTS451 Remote Test Station INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com Operation Test Function Place and hold the painted side of the magnet to the RTS451 on the right or left side of the LED as indicated in the dia- gram above. Alarm Indication With the magnet in place some time will elapse (40 sec. maximum) depending on the detector type, before the alarm indicating LED will light. Reset Function Gently insert a 1/8˝ maximum diameter tool into the hole un- til it stops and LED turns off. The RTS451 is capable of reset- ting only certain System Sensor models of detectors. Refer to detector installation instructions for additional information. H0196-00 I56-0469-010 D440-01-00 2 I56-0469-010 ©2007 System Sensor Three-Year Limited Warranty System Sensor warrants its enclosed product to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for the enclosed product. No agent, representative, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obliga- tion of this Warranty shall be limited to the replacement of any part of the product which is found to be defective in materials or workman- ship under normal use and service during the three year period com- mencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Returns Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to replace units which are found to be defective because of damage, unreasonable use, modi- fications, or alterations occurring after the date of manufacture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limita- tion of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Figure 2. Wiring diagram for RTS451 to DH100ACDC 4-Wire Duct Smoke Detector: Figure 3. Wiring diagram for RTS451 to DH100 2-Wire Duct Smoke Detector: 15 20 2 11 2 1 Alarm Signal + Aux. Power – Reset Test (Red LED) Alarm DH100ACDC RTS451 5 4 3 Reset Test Field Installed Jumper 1 2 3 4 5 6 3 4 5 Test + Test / Reset – Reset + Test Reset RA + RA – V Out + DH100 RTS451 KEY 6 2 1 Alarm LED No Connection H0198-01 H0197-00 Figure 4. Wiring diagram for RTS451 to DH400ACDC Duct Smoke Detector: ALARM SIGNAL (+) AUX POWER (–) 5 6 1 2 R E D 5 3 4 3 RESET TEST 4 FIELD INSTALLED JUMPER RESET (–) TEST (–) DH400ACDC RTS451 H0149-01 Figure 5. Wiring diagram for RTS451/RTS451KEY to BEAM1224/BEAM1224S Smoke Detector: 1 2 3 4 5 3 2 1 5 4 RTS451/RTS451KEY BEAM1224/BEAM1224S REMOTE ALARM OUT AUX (–) TEST INPUT REMOTE TROUBLE OUTPUT RESET INPUT TEST RESET T2-3 T3-3 T2-4 T2-2 T2-1 OPTIONAL YELLOW LED NOTE: RTS451/RTS451KEY CAN BE USED WITH INTELLIGENT BEAM DETECTOR PRODUCTS. CONSULT INTELLIGENT BEAM DETECTOR MANUAL FOR ADDITIONAL INSTRUCTIONS (RED LED) ALARM H0586-00

Document Preview & Text Transcription

D440-01-00 1 I56-469-08 NOTICE: This manual shall be left with the owner/user of this equipment. NOTE: A test coil is required only for use with DH400/ DH500 models and requires ordering of part #COIL. General Information System Sensor’s RTS451 is an automatic fire detector accessory designed to test a remotely located detector. Consult detector installation instructions for additional information. The National Fire Protection Association has published codes, standards, and recommended practices for the installation and use of the above product. It is recommend- ed that the installer be familiar with these requirements, with local codes, and any special requirements of the local authority having jurisdiction. RTS451 Contents 1 RTS451 remote test station 1 #4 screw for mounting bracket 1 screw pack (2 mounting screws) 1 M02-04 test magnet Wiring of RTS451 Consult the appropriate detector installation instructions for the applicable wiring diagram. The RTS451 mounts to a single gang box (21/2” minimum depth), or directly to the wall or ceiling. Specifications Dimensions: 4.6″ H × 2.75″ W × 1.5″ D Weight: .11 lbs. Power Requirements: Alarm LED: 2.8 – 32 VDC, 7.5 mA max. Total Current: 105 mA max. Test Switch: 10 VA @ 32 VDC Reset Switch: 10 VA @ 32 VDC Alarm Response Time: 40 sec. max. Temperature: –10°C to 60°C (14°F to 140°F) Humidity: 95% RH Non-condensing ALARM RESET M02-04 TEST MAGNET LOCATIONS Figure 1. RTS451 Remote Test Station RTS451 Remote Test Station INSTALLATION AND MAINTENANCE INSTRUCTIONS 3825 Ohio Avenue, St. Charles, Illinois 60174 1-800-SENSOR2, FAX: 630-377-6495 www.systemsensor.com See Figure 2 for wiring diagram of RTS451 with DH100ACDC Duct Smoke Detector. In Canadian applications, the RTS451 is intended to be located in the same room as the smoke detector and within 60 feet of the unit. H0196-00 D440-01-00 2 I56-469-08 ©2003 System Sensor Three-Year Limited Warranty System Sensor warrants its enclosed remote test station to be free from defects in materials and workmanship under normal use and service for a period of three years from date of manufacture. System Sensor makes no other express warranty for this remote test station. No agent, representa- tive, dealer, or employee of the Company has the authority to increase or alter the obligations or limitations of this Warranty. The Company’s obligation of this Warranty shall be limited to the repair or replacement of any part of the remote test station which is found to be defective in materials or workmanship under normal use and service during the three year period commencing with the date of manufacture. After phoning System Sensor’s toll free number 800-SENSOR2 (736-7672) for a Return Authorization number, send defective units postage prepaid to: System Sensor, Repair Department, RA #__________, 3825 Ohio Avenue, St. Charles, IL 60174. Please include a note describing the malfunction and suspected cause of failure. The Company shall not be obligated to repair or replace units which are found to be defective because of damage, unrea- sonable use, modifications, or alterations occurring after the date of manu- facture. In no case shall the Company be liable for any consequential or incidental damages for breach of this or any other Warranty, expressed or implied whatsoever, even if the loss or damage is caused by the Company’s negligence or fault. Some states do not allow the exclusion or limitation of incidental or consequential damages, so the above limitation or exclusion may not apply to you. This Warranty gives you specific legal rights, and you may also have other rights which vary from state to state. Operation Test Function Place and hold the painted side of the magnet to the RTS451 on the right or left side of the LED as indicated in the diagram above. Alarm Indication With the magnet in place some time will elapse (40 sec. maximum) depending on the detector type, before the alarm indicating LED will light. Reset Function Gently insert a 1/8″ maximum diameter tool into the hole until it stops and LED turns off. The RTS451 is capable of resetting only certain System Sensor models of detectors. Refer to detector installation instructions for additional information. Figure 2: Wiring diagram for RTS451 to DH100ACDC 4-Wire Duct Smoke Detector Figure 3: Wiring diagram for RTS451 to DH100 2-Wire Duct Smoke Detector 15 20 2 11 2 1 Alarm Signal + Aux. Power – Reset Test (Red LED) Alarm DH100ACDC RTS451 5 4 3 Reset Test Field Installed Jumper 1 2 3 4 5 6 3 4 5 Test + Test / Reset – Reset + Test Reset RA + RA – V Out + DH100 RTS451 KEY 6 2 1 Alarm LED No Connection H0198-01 H0197-00 Figure 4: Wiring diagram for RTS451 to DH400ACDC Duct Smoke Detector ALARM SIGNAL (+) AUX POWER (–) 5 6 1 2 R E D 5 3 4 3 RESET TEST 4 FIELD INSTALLED JUMPER RESET (–) TEST (–) DH400ACDC RTS451 H0149-01