Teledyne 6712 Manuals

2 pdf manual(s) Teledyne 6712 for free download (Document Types: Assembly, installation and operation manual, Pocket manual)

Document Preview & Text Transcription

Information included herein is controlled by the Export Administration Regulations (EAR) and requires an export license, license exception or other approval from the appropriate U.S. Government agency before being exported from the United States or provided to any foreign person. Diversion contrary to U.S. law is prohibited. 6712 LTE Cellular Modem Installation and Operation Overview This modem can transmit SMS text message alarms to cell phones and/or email addresses, and receive SMS text message commands, via the Internet. Sampler firmware version 3.04 or newer is required for the 6712 LTE modem. This firmware will only work with C0 hardware. To verify the hardware of your sampler: 1. Go to VIEW REPORT. 2. Select SYSTEM IDS. 3. The hardware version will appear in the display. Equipment part numbers: • 6712LTE Cellular Modem Kit (modem module with magnetic mount antenna) Part #60-9004-499 - Verizon Part #60-9004-517 - Other • Antenna Only Part #60-4804-035 Note When the 6712 LTE modem is used, the baud rate is locked at 9600bps. Ensure that this setting is also selected in Flowlink or Hyperterminal. Programming the APN The APN (Access Point Name – for Data) is stored in the 6712 Sampler head. 1. Plug the com cable directly to the 6712. 2. Connect with a terminal program and type ???? 3-4 times to log in. The Sampler will beep. 3. When you see the “>” type “APN” then ENTER. The following screen will appear: 4. Choose “1” to input the APN. 5. Type in the name and press enter. The screen will update with the APN below the entry screen: 6. Pressing “0” to save the setting gets you the “>” again. You can now disconnect via Terminal. 7. Close the Terminal. 8. Now you can connect the modem to the sampler and program the sampler accordingly. 6712 LTE Modem Activation and Setup The item in bold is the current selection; use the arrow keys to scroll and press to accept: > APN 1. Name: empty 2. User: empty 3. Password: empty Press 1,2,3 to change or 0 if ok > APN 1. Name: empty 2. User: empty 3. Password: empty Press 1,2,3 to change or 0 if ok Enter Name: > APN 1. Name: empty 2. User: empty 3. Password: empty Press 1, 2, 3 to change or 0 if ok Enter Name:i2gold 1. Name: i2gold 2. User: empty 3. Password: empty Press 1,2,3 to change or 0 if ok > APN 1. Name: empty 2. User: empty 3. Password: empty Press 1, 2, 3 to change or 0 if ok Enter Name:i2gold 1. Name: i2gold 2. User: empty 3. Password: empty Press 1,2,3 to change or 0 if ok > RUN “EXTENDED 1” PROGRAM VEIW REPORT OTHER FUNCTIONS MAINTENANCE MANUAL FUNCTIONS SOFTWARE OPTIONS HARDWARE Instruction Sheet #69-9003-676 Rev. F, May 2021 EAR-Controlled Technology Subject to Restrictions Contained on page 1. Instruction Sheet #69-9003-676 Rev. F, May 2021 Step through the program, enabling any desired alarms (I/O1, I/O2, I/O3). Note Three types of modems: TELIT (for CDMA or GSM or LTE Telit modems), GELS3 (for GELS3 LTE modems), and UMT (for older GSM modems) will be shown; select the appropriate one. Power Settings Next, you will need to select one of three power on modes, depending on your power conservation requirements: Power Always On – The modem stays constantly powered. Message Check – The modem powers on at user-selected intervals to poll for valid incoming SMS messages. If a message is detected, the sampler will keep the modem powered up for the next 20 minutes, ready to receive incoming messages. Alarms Only – The modem powers on only to transmit alarm messages. Notification List As detailed in the Extended Programming section of the sampler manual, when any programmed and enabled I/O output enters a true state, the sampler can send an SMS text message to a list of up to three phone numbers. With the 6712 LTE modem, the sampler can also send the message to up to three email addresses. Email Setup Email addresses are programmed into the sampler with HyperTerminal. 1. Connect your computer to the sampler’s interro- gator port with the standard interrogator cable: Part #60-2544-044 for 9-pin serial port; part #60-2004-508 for USB port. 2. In Hyperterminal, use the following communica- tion settings: • baud rate 9600bps • no parity • 8 data bits • 1 stop bit • VT100 terminal emulation 3. On the computer, press and hold the question mark (?) until the sampler returns its banner string. A caret (>) prompt will appear when the sampler is ready for input. Press Enter (CR) after every command. 4. At the prompt, enter the word "email." Then fol- low the sequence shown in Figure below. Note A combination of phone numbers/email addresses can be used. Any phone numbers already programmed for I/O 1, 2, or 3 will appear in Hyperterminal instead of the word “empty.” NO EXTERNAL MODEM SELECT EXTERNAL MODEM TYPE: NONE TELIT GELS3 UMT EXT TELIT MODEM POWER ALWAYS ON MESSAGE CHECK ALARMS ONLY MODEM CONNECTOR POWER ALWAYS ON MESSAGE CHECK 5 10 15 MINUTES MODEM CONNECTOR POWERED FOR MESSAGE CHECK EVERY 10 MINUTES MODEM CONNECTOR POWERED FOR ALARMS ONLY EAR-Controlled Technology Subject to Restrictions Contained on page 1. Instruction Sheet #69-9003-676 Rev. F, May 2021 SMS Commands Commands to start the program, load a selected pro- gram, enable/disable the sampler, take a sample, and report sampler status, can be sent to the sampler by cell phone or by email. When you send a command to the sampler, it will carry out the command and also respond with an acknowledging message to all programmed destination phone numbers/email addresses. With a cell phone, simply send the command in a text message to the 6712 LTE modem’s phone number. When using email, send the command either in the sub- ject line or body of the email, to: [phone number]@vtext.com. The command must contain the string “6712,” along with one of the commands listed in Table 1. The middle and right columns are interchangeable, with the right column containing abbreviated commands. Commands are not case-sensitive, and do not require spacing. Example Command: 6712status Shortened Version: 6712C9SMS Messages Sent From the Sampler Response messages and alarms sent out by the sam- pler contain the sampler’s three-digit ID number, the site name, and IP address (if applicable), followed by either the command response or alarm condition. Example Response: ISCO Sampler 148, FACTORY148, IP:##.###.###.###, Sampler Status: Program Done Example Alarm: ISCO Sampler 148, FACTORY148, IP:##.###.###.###, alarm 1 PGM ENABLED To acknowledge an alarm, copy the text and send it back to the sampler. This will stop the user from receiving the same message up to five times. Dual Sampler Setup To set up a dual-sampler system where one sam- pler’s program is triggered by the enable alarm of another, program the primary (master) sampler to send an SMS alarm message of "Program Enabled" to the phone number of the secondary (slave) sampler. Program the secondary sampler to start with a delay setting of WAIT FOR PHONE COMMAND. SIM Card The data transmission capabilities of the 6712 LTE are dependent upon the type of service plan you have through your cell phone service provider. The service parameters, or provider, can be changed by simply replacing the SIM card in your 6712 LTE. Check with your service provider to verify what data transmission technologies are available for your use. There are three types of SIM cards, but only the Micro SIM cards will work with the 6712 LTE modems (Figure 1). Note A Micro SIM card is required for any LTE units including the 6712 LTE. Table 1: 6712 LTE SMS Commands Prefix Command Short Version 6712 START C0 RUN1 C1 RUN2 C2 RUN3 C3 RUN4 C4 DISABLE C5 ENABLE C6 TAKE SAMPLE C7 STATUS C9 ���������� �������� �������� �������� ���������������������������������� ������ ������������� ����������� ����!�"�����#�������� ������ ����!�"�����#��� �������� �������� After entering "email," the following appears. After selecting the I/O pin, the following prompt appears. Enter the address to be used. After entering the address, changes are reflected. To add another address, enter the word "email" again.
Teledyne 6712 Pocket manual Main Page Preview

Pocket manual [PDF] (64 pages)

  • Updated: 13.03.2026

Document Preview & Text Transcription

6712 Sampler This pocket guide is not intended to replace the instruction manual. Read the instruction manual thoroughly before operating the sampler. COPYRIGHT © 2001-2003 by Teledyne Isco, Inc., 4700 Superior St., Lincoln, Nebraska, U.S.A. 68504 Phone: (402) 464-0231 Toll Free: (800) 228-4373 FAX: (402) 465-3022 Part #69-9003-589 Issued: January, 2001 Revision C, December 2003 i 6712 Sampler Table of Contents 1. Programming 1.1 Getting Started . . . . . . . . . . . . . . . . . 1-3 1.2 Using Menus and Entering Numbers 1-4 1.2.1 Selecting Menu Options . . . . . 1-4 1.2.2 Entering Numbers . . . . . . . . . 1-4 1.2.3 Clock and Calendar Entry Screens . . . . . . . . . . . . . . . . . . . . . . . . . 1-9 1.3 Quick View Screens . . . . . . . . . . . . . 1-11 1.3.1 Paging Through the Quick View Screens . . . . . . . . . . . . . . . . . 1-12 1.3.2 Changing Settings in a Quick View Screen . . . . . . . . . . . . . 1-12 1.4 Help Notes . . . . . . . . . . . . . . . . . . . . 1-13 1.5 Warning Messages . . . . . . . . . . . . . . 1-13 1.6 Changing to and from Extended and Standard Screens . . . . . . . . . . . . . . . 1-14 1.7 Storage For Extended Programs . . . 1-14 1.8 Programming the Modules . . . . . . . 1-16 1.9 Programming SDI-12 Sondes . . . . . 1-17 1.9.1 Stored Programs . . . . . . . . . . 1-17 1.10 Programming Examples . . . . . . . . . 1-19 2. Operation 2.1 Installation and Operation Checklist 2-1 2.2 Installing Distributor Arm . . . . . . . . 2-2 2.3 Installing Bottle Kits . . . . . . . . . . . . . 2-6 2.4 Positioning a Sampler . . . . . . . . . . . . 2-7 2.5 Connecting An External Instrument 2-8 2.5.1 Flow Meter Connector . . . . . . 2-8 2.5.2 Rain Gauge Connector . . . . . . 2-9 6712 Sampler ii 2.6 Running Programs . . . . . . . . . . . . . . . 2-9 2.7 Interrupting a Running Program . . . 2-9 2.8 Run Time Screens . . . . . . . . . . . . . . 2-10 2.8.1 Module and SDI-12 Sonde Readings . . . . . . . . . . . . . . . . 2-11 2.9 Error Messages . . . . . . . . . . . . . . . . 2-11 2.9.1 Fatal Error . . . . . . . . . . . . . . 2-12 2.10 Recovering the Sampler . . . . . . . . . . 2-12 2.11 Viewing the Data . . . . . . . . . . . . . . . 2-13 2.12 Configuring Reports . . . . . . . . . . . . . 2-14 2.13 Grab Samples . . . . . . . . . . . . . . . . . . 2-15 2.14 Calibrating . . . . . . . . . . . . . . . . . . . . 2-17 2.14.1 Calibration Tips . . . . . . . . . . 2-18 3. Reference 3.1 Replacing the Pump Tube . . . . . . . . . 3-1 3.1.1 Pump Tube Warning . . . . . . . 3-1 3.1.2 Checklist For Replacing Pump Tube . . . . . . . . . . . . . . . . . . . . . 3-2 3.2 Rinses and Retries . . . . . . . . . . . . . . . 3-5 3.3 Pacing . . . . . . . . . . . . . . . . . . . . . . . . . 3-5 3.4 Distribution . . . . . . . . . . . . . . . . . . . . 3-6 3.4.1 Sequential . . . . . . . . . . . . . . . . 3-6 3.4.2 Bottles Per Sample . . . . . . . . . 3-8 3.4.3 Samples Per Bottle . . . . . . . . 3-10 3.4.4 Composite . . . . . . . . . . . . . . . 3-12 3.4.5 Multiple Bottle Compositing 3-12 3.5 Sampler Enable . . . . . . . . . . . . . . . . 3-12 3.6 Start Times . . . . . . . . . . . . . . . . . . . . 3-13 3.7 Operating the Pump . . . . . . . . . . . . 3-17 3.8 Moving the Distributor Arm . . . . . . 3-18