Texas Instruments AN-1975 LMP8640 Manuals
1 pdf manual(s) Texas Instruments AN-1975 LMP8640 for free download (Document Types: Operation & user’s manual)
Texas Instruments AN-1975 LMP8640 Operation & user’s manual [PDF] (8 pages)
- Identifier: id-1091650
- Brand: Texas Instruments
- Device: AN-1975 LMP8640 Motherboard
- Type: PDF
- Key Aspects: Safety Recommendations and Warnings, Environmental Factors and Restrictions, Additional Modules and Accessories Guide
- UPD Date: 03.08.2026
- Source File: 1066750.pdf
- Pages: 8
- Description: Complete instruction guide for the Texas Instruments AN-1975 LMP8640.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
User's Guide SNOA546C–November 2009–Revised April 2013 AN-1975 LMP8640/LMP8645 Evaluation Board 1 Introduction This evaluation board shows a bidirectional high-side current sense made using LMP8640 (LMP8645) and optional differential amplifier in order to have a single output. 2 Connectors 2.1 Power Supply There are two banana plugs labeled GND and VCC to power the evaluation board. Moreover, a banana plug labeled VCC_Amp is used to power an optional operational amplifier that makes the difference between the outputs of the two LMP8640 (LMP8645). 2.2 Signal Connectors There are five connectors for signals. Table 1. Input signals IN It connects the non inverting input of U1 and inverting input of U2. LOAD It connects the non inverting input of U2 and inverting input of U1. The device U1 is able to sense the current when it flows in the shunt resistor from the LOAD pin to the IN pin. The device U2 is able to sense the current when it flows in the shunt resistor from IN pin to LOAD pin. Table 2. Output signals OUT+ Output of device U2, the voltage at this pin is related to the current that flows from the IN pin to the LOAD pin. OUT- Output of device U1, the voltage at this pin is related to the current that flows from the LOAD pin to the IN pin. OUT Optional Output of the difference amplifier that makes the difference between OUT+ and OUT- 3 Hardware Setup 3.1 Power Supply Setup • High side current sense LMP8640 (LMP8645) – Connect a supply voltage in the range between 2.7 V and 12 V to the VCC and GND turrets. • Optional difference amplifier – Connect a supply according to the specs of the amplifier to the VCC_Amp and GND turrets. All trademarks are the property of their respective owners. 1 SNOA546C–November 2009–Revised April 2013 AN-1975 LMP8640/LMP8645 Evaluation Board Submit Documentation Feedback Copyright © 2009–2013, Texas Instruments Incorporated