thermital ACQUAHOME R BLU Series Manuals
1 pdf manual(s) thermital ACQUAHOME R BLU Series for free download (Document Types: Installation and maintenance manual)
Available Documents for ACQUAHOME R BLU Series:
Brand: thermital
Model: ACQUAHOME R BLU Series
Format: PDF
Key Aspects: Recommended Spare Parts List, User Training Recommendations, System Connectivity and Wiring Basics
Updated: 27.07.2026
Source File: 1661834.pdf
Pages: 56
Description: Complete operating guide for the thermital ACQUAHOME R BLU Series.
Contents
Document Preview & Text Transcription
ACQUAHOME R BLU
INSTALLATION AND
MAINTENANCE MANUAL
2
ENGLISH
RANGE
MODEL
CODE
ACQUAHOME 25 R BLU
20132486
ACQUAHOME 32 R BLU
20132487
ACCESSORIES
For a complete list of accessories and details of their compati-
bility, refer to the Catalogue.
CONFORMITY
ACQUAHOME R BLU boilers conform to the following directives:
- Directive 92/42/EEC on efficiency requirements
- Electromagnetic Compatibility Directive 2014/30/EU
- Low Voltage Directive 2014/35/EU
- Ecodesign Directive 2009/125/CE for energy-related
products
- Regulation (EU) 2017/1369 Energy labelling
- Delegated Regulation (EU) N. 811/2013
- Delegated Regulation (EU) N. 813/2013
- Delegated Regulation (EU) N. 814/2013
At the end of its life, the product should
be not be disposed of as solid urban
waste, but rather it should be handed over
to a differentiated waste collection centre.
Dear heating engineer,
Congratulations on having chosen a T boiler. You
have selected a modern, quality product that is designed to
give dependable, efficient and safe service and to provide
comfort in the home for many years to come.
This manual provides information that is essential to the in-
stallation of the appliance. Used in conjunction with your own
knowledge and expertise it will enable you to install the appli-
ance quickly, easily, and correctly.
Please accept our thanks and our congratulations on your
choice of product.
Thermital
ENGLISH
3
ENGLISH
This manual, Code 20129584 - Rev. 1 (10/18) comprises 56 pages.
CONTENTS
The following symbols are used in this manual:
b CAUTION! = Identifies actions that require caution and
adequate preparation.
a STOP! = Identifies actions that you MUST NOT do.
This manual, Code
- Rev.
comprises
pages.
GENERAL INFORMATION . . . . . . . . . . . . . . . . . . . . . 4
General Safety Information . . . . . . . . . . . . . . . . . . . . . . . . . .4
Precautions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .4
Description of the appliance . . . . . . . . . . . . . . . . . . . . . . . . .4
Safety and control devices . . . . . . . . . . . . . . . . . . . . . . . . . .5
Identification . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .5
System layout . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .6
Technical specifications . . . . . . . . . . . . . . . . . . . . . . . . . . . .8
Pump . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .9
Location of sensors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .10
Control panel . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .11
INSTALLATION . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 13
Unpacking the product . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Positioning of labels . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .13
Overall dimensions and weights . . . . . . . . . . . . . . . . . . . . .13
Moving and removing the packing . . . . . . . . . . . . . . . . . . .14
Installation premises . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Recommended minimum distances . . . . . . . . . . . . . . . . . .15
Installation in older systems and systems requiring
modernisation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .15
Water connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Boiler water circuit . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .16
Typical system schematic . . . . . . . . . . . . . . . . . . . . . . . . . .17
Fuel connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .17
Discharge of combustion products . . . . . . . . . . . . . . . . . . .18
Technical specifications of stack . . . . . . . . . . . . . . . . . . . . .19
Connection to the stack . . . . . . . . . . . . . . . . . . . . . . . . . . . .19
System filling and emptying . . . . . . . . . . . . . . . . . . . . . . . .20
Water quality requirements . . . . . . . . . . . . . . . . . . . . . . . . .20
Filling . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Emptying . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .21
Wiring diagram . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .22
Electrical connections . . . . . . . . . . . . . . . . . . . . . . . . . . . . .23
Menu navigation . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .25
Enter password . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .26
Navigation scheme . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .27
List of parameters . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .28
COMMISSIONING AND MAINTENANCE . . . . . . . . 34
Preparing for initial startup . . . . . . . . . . . . . . . . . . . . . . . . .34
Initial startup . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .34
Adjustment of heating setpoint . . . . . . . . . . . . . . . . . . . . . .35
Enable/disable the heating function . . . . . . . . . . . . . . . . . .36
Setting the heating parameters . . . . . . . . . . . . . . . . . . . . . .36
Special functions . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .39
Ignition failure . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .40
Checks during and after initial start-up . . . . . . . . . . . . . . . .40
Burner control and adjustment . . . . . . . . . . . . . . . . . . . . . .41
Burner functioning and programming . . . . . . . . . . . . . . . . .42
Error List . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Permanent Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Temporary Errors . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Warnings . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .49
Temporary or short-term shut-down . . . . . . . . . . . . . . . . . .50
Preparing for extended periods of disuse . . . . . . . . . . . . . .50
Device cleaning and maintenance . . . . . . . . . . . . . . . . . . .50
Annual cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .50
Cleaning and maintaining the burner . . . . . . . . . . . . . . . . .50
Boiler exchanger cleaning . . . . . . . . . . . . . . . . . . . . . . . . .52
External cleaning . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .53
Troubleshooting . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .54
RECYCLING AND DISPOSAL . . . . . . . . . . . . . . . . . 55
ACQUAHOME R BLU Series: Related Instructions
Manuals from Other Manufacturers