Assembly instruction manual [PDF] (12 pages)
- Updated: 13.04.2026
Document Preview & Text Transcription
THS3002-1220 Printed in Canada
EX Series
Special Notes
CAUTION
CAUTION. This document presents the minimum requirement pertaining
to the installation, operation, and maintenance of the respective
equipment as required by the manufacturer only. Any additional
considerations, including but not limited to any design consideration,
in-service inspection, and fitness-for-service assessment for all pressure
boundary components to meet any safety principles and local jurisdictional
regulatory requirements, shall be the responsibility of the user.
ELECTRIC SHOCK HAZARD. All electric heating equipment installations
must be performed by qualified personnel in accordance with the local
electrical codes and standards and must be effectively grounded to
eliminate shock hazard.
WARNING
FIRE/EXPLOSION HAZARD FOR EXPLOSIVE ATMOSPHERE HEATERS.
This heater shall be used with protection controls as follows:
Liquid Immersion Applications
a.
Liquid level control to maintain all the heating elements totally
immersed at all times, in conjunction with temperature controls to limit
the liquid temperature below the maximum allowable process design
temperature.
b. Terminal box internal surface temperature control to limit the surface
temperature of the terminal box
c.
Heater flange surface temperature control to limit the surface
temperature of the flange.
d. Heating elements sheath temperature controls to limit to the maximum
allowable sheath design temperature
e.
Earth fault or earth leakage current protection device to protect against
arcing and sparking during an earth fault.
Gaseous and/or vapour phase immersion applications
a.
Heating elements sheath temperature controls to limit to the maximum
allowable sheath design temperature.
b. Terminal box internal surface temperature control to limit the surface
temperature of the terminal box
c.
Heater flange surface temperature control to limit the surface
temperature of the flange.
d. Earth fault or earth leakage current protection device to protect against
arcing and sparking during an earth fault.
CAUTION
Circulation Heaters
ISO 9001
Installation, Operation, & Maintenance Instructions
For CE/ATEX and IECEx Models. Models with
Increased Safety (Type eb) Protection Method
22
WARNING
Fire/Explosion Hazard. Do not exceed the ratings of the flange as listed in
ANSI BI6.5. In case of code stamped of registered heater, do not exceed
the rating as stated in the data report and/or registration documents. Do
not operate the heater in the presence of combustible gases, vapours,
dusts or fibres unless the heater is specifically marked for the hazardous
location and heater operating temperature does not exceed the
temperature code rating. Corrosion of the sheath could result in a ground
fault which, depending upon the fluid being heated, could cause a fire or
an explosion.
WARNING
Fire Hazard. If a thermostat is provided, it is designed for temperature
control service only. Since the thermostat does not fail safe, it should not
be used for temperature limiting duty. Wiring to this device is the users'
responsibility.
Heaters are capable of developing high temperatures, therefore extreme
care should be taken to:
a.
Use explosion-proof terminal enclosures in explosive atmospheres.
b.
Maintain distance between heater and combustible materials.
The heater must be installed and operated in accordance with the following
specific conditions of use:
1.
The heater shall be installed with electrical safety devices as described in the Installation, Operating and
Maintenance manual and in accordance with local codes and standards.
2.
It is the user’s responsibility to connect the installed temperature sensors to safety devices as defined in
IEC 60079-0, that are fail-safe and can only be reset manually. The temperature monitoring circuit shall
be set according to the controller set point label on the equipment and used to disconnect the supply
when operated.
3.
Anti-condensation heater, if used, shall be prevented from operating while the immersion heater is in
operation.
4.
The temperature classification of the heater is based on the complete immersion of the heater elements
in either a fluid or gas. Depending on the use of the heater, a flow or liquid level device must be used to
ensure immersion in the process medium. Refer to the Installation, Operating and Maintenance manual
for details.
5.
The heater must be installed in accordance within the operating parameters taken from the nameplate,
caution labels, instruction manual and condition of use documentation.
6.
An electrical protection device must be installed to protect against earth related faults in accordance
with the Installation, Operating and Maintenance manual.
3
TABLE OF CONTENTS
A. Diagrams ............................................4
B. Description ........................................6
C. Installation .........................................7
D. Operation ...........................................8
E. Maintenance .....................................9