Technical Notification
September 2005
Document no. 20050926
Sailor RT5022 VHF DSC
Subject:
Incorrect factory setting of power output in DSC and Distress-transmission.
Identification:
It has just come to our attention that in a limited number of RT5022 VHF DSC of recent
production the RF output power in DSC transmission has erroneously been set to 1W rather
than 25W, caused by an incorrect setup in the production final test equipment.
The serial number identification of units to which this erroneous power setting may apply
is found within the range of s/n 05737163 through s/n 05749592.
The incorrect power setting may be operationally verified by the <1W> indicator lamp in the
display lighting, when transmitting a DSC-call.
Action:
It is imperative that this DSC power setting be reset to 25W in all units identified within
the above mentioned serial number range as this power setting applies to the Distress
transmission also.
To accomplish the required reset of the DSC-transmission output power, a program has
been created that will automatically reset to correct power level. The procedure requires
the use of an SB5006 service tool. Follow the procedure described below to accomplish the
successful reset of the DSC power level to 25W.
NOTE: This procedure is applicable only to VHF radios with Main Release 1.30 software,
but otherwise harmless to other versions.
Applying the fix to the VHF radio:
The patch is enclosed in a zip file (TT_RT5022_patch_w39.zip) and available for download
at http://www.extranet.thrane.com/. Prior to proceeding with the described DSC power
reset, unpack the zip file contents (a directory named TT_RT5022_patch_w39) and save
this on your service pc desktop.
Pls. refer to the SB5006 Operation Manual also available for download at the Extranet for
details on the use of the Service Box SB5006/Service Tool.
Proceed as follows:
1) Connect the SB5006 Service Box to the RT5022 and the service PC (refer to the
SB5006 Operation Manual).
2) Switch on the RT5022 VHF.
3) Double-click on the TT_RT5022_patch_w39 icon on your desktop to open the directory
contents:
Double-click on the RT5022.exe icon and the following window appears:
4) Leave default settings as indicated – unless you have changed IP address on your
SB5006 Service Tool.
Technical Notification
XXXXX
Page 2/4
5) Press Connect to Lanbox. The window should display the following message:
If the message does not appear as described please check your setup; RT5022, SB5006,
etc. and close the program. Then retry the procedure.
6) Now press Patch DSC low power. The patch is now executed. The detail progress is
reported in the window. A successful fix will show the following transcript:
Technical Notification
XXXXX
Page 3/4
Technical Notification
XXXXX
Page 4/4
If the program fix is applied to radios with software different from Main Release 1.30 the
following transcript might be seen, showing the fix is not needed on this version.
7) After successful update close the window.
Important: After having executed the patch, the successful reset of the power setting to
25W should be verified by performing a DSC call, and noting that the <1W> indicator in the
VHF display does not light during the DSC transmission.
We kindly request, that the serial numbers of the RT5022 VHF DSC to which this patch is
applied be reported by an email addressed to [email protected].