TKB Home E91.713 Manuals

1 pdf manual(s) TKB Home E91.713 for free download (Document Types: Instructions)

TKB Home E91.713 Instructions [PDF] (2 pages)

  • Identifier: id-1369694
  • Brand: TKB Home
  • Device: E91.713 Thermostat
  • Type: PDF
  • Key Aspects: Best Practices for Everyday Use, Emergency Shutdown Procedures, Hardware Verification Checklists
  • UPD Date: 06.04.2026
  • Source File: 1358061.pdf
  • Pages: 2
  • Description: Detailed user guide for the TKB Home E91.713.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
E91.713 E91.723 E91.716 3A 3A 16A 6PRG:Set day off mode Press + or - to choose day off 5/2 day mode,6/1day mode,7 day mode Re-press manu key to enter to next step. Modify Modify Temp. Temp. 1 2 3 4 5 6 1 2 20℃ 15℃ 15℃ 15℃ 22℃ 15℃ 22℃ 15℃ 06:00 08:00 11:30 12:30 17:00 22:00 08:00 23:00 DS/MRD-06-091124 Weekly circulation digital programming thermostat with LCD touch screen,which has 6-event everyday. Manual mode and programme mode could be selec- ted.The thermostat is recommended for control of electric heating devices or on/off valve actuator used in hydronic floor heating. E91...Touch Screen Programming Thermostat Selection Table: Model Current Application Built-in&floor sensor,floor limit sensor weekly programme Built-in&floor sensor,floor limit sensor weekly programme Built-in&floor sensor,floor limit sensor weekly programme,a potential-free output Parameter: Voltage:220V/230V Power comsuption:2W Setting range:5~90℃(can adjust to 35-90?) Ambient temperature:-5~50℃ Protective houseing:IP20 Housing material: anti-flammable PC Limitation setting:5...60? (Factory setting:35?) User operation: Function: Manual mode Manual mode Clock-controlled programme mode Clock-controlled programme mode Heating on Heating on Wake-up,event 1 Wake-up,event 1 Leave(am),event 2 Leave(am),event 2 Return(am),event 3 Return(am),event 3 Leave(pm),event 4 Leave(pm),event 4 Return(pm),event 5 Return(pm),event 5 Sleep,event 6 Sleep,event 6 Programming: Press Manu key for 5 seconds to start programming Press Manu key for 5 seconds to start programming Key Event Symbol Time Event Time 1-5 6-7 Note: 1) The pre-programmed setpoint(15℃) for event 3&4 is the same as event 2,please reset it according to your individual requirement. 2)Symbol“OFF”will be displayed if the setpoint reaches the minimum set value and the thermostat is switch off in this event. Usually finished at mounting thermostat. Press key simultaneously press power on key when in power off. 1ADJ:Temperature calibration Press� or �key to adjust present checked value,adjustable scale:9.9℃. Re-press manu key to enter to next step. 2SEN:Sensor mode Press�or�key to choose senor working mode IN:built-in,OUT:floor sensor, ALL:both sensors,floor sensor is the limit sensor Re-press manu key to enter to next step. 3LIT: Modify limition value Press�or�key to modify the temp. Limit valuelimition range:5~60� Re-press manu key to enter to next step. 4DIF:Switch differential setting Press�or�key to change switch defferential Setting range:0.5~10�. Re-press manu key to enter to next step. 5LTP:Start anti-frozen function in power off Press�or�key to change the present anti- frozen function Re-press manu key to enter to next step. 7RLE:Potential-free output and main power output in same/different way. Press�or�key to change the present linkage state. 00:in same way,01:in defferent way? Re-press manu key to enter to next step. 8DLY:Delay time of potential-free output Press�or�key to change linkage delay time Range:0-5min. Re-press manu key to enter to next step. 9HIT:Max. Temperature setting Press�or� key to change the Max.value Range:35-90? Re-press manu key to enter to next step. AFAC:Reset to factory setting Press�key for 5seconds till showing --- Reset to factory setting Swithch off for saving setting INSTRUCTIONS Switch differential:0.5-10? adjustable factory setting1? Day Day Advanced setting(qualified person preferred): 1) 2)At clock-controlled programme mode,press“ ”or“ ” enter to temporary control. 3)UP“ ”,DOWN“ ”to adjust the temperature value. 4)press clock “ ”key for 5 seconds,then enter to clock set, choose modified item by pressing clock“ ”,press UP/DOWN“ ”to modify the date and clock,then switch off to quit. 5)press manu“ ”to choose manual mode or programme mode. 6)set temperature and clock display alternately,room tem- perature can be read out directly. 7)press both “ ”“ ”for five seconds to engage/dise-ngage key-lock function key-lock on shows“ ” (“ ”this symbol dispeared that shows key-lock off) on/off.“ ”

E91.713: Related Instructions

TKBETZ69-CH
TKB Home TKBETZ69-CH
08.06.2026 9 pages

TKB Home Smart energy plug in switch SKU: TKBETZ69-CH Quickstart This is a On/Off Power Switch for Europe. To run this device please connect it to your mains po Instruction manual for the TKB Home TKBETZ69-CH Home Automation. It includes usage scenarios and component replacement, safety guidelines, testing procedures, troubleshooting tips.

TZ68
TKB Home TZ68
02.05.2026 2 pages

This plug-in ON/OFF Module in a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices dis Usage and setup manual for the TKB Home TZ68 Home Automation. It provides guidance on wiring setup, software updates, usage examples.

TKBETZ67-G
TKB Home TKBETZ67-G
06.07.2026 3 pages

TKB Home Z-Wave Wall Plug Dimmer for Type F SKU: TKBETZ67-G Quickstart This is a Light Dimmer for Europe. To run this device please connect it to your mains pow Stepwise user guide for the TKB Home TKBETZ67-G Home Automation. The manual provides technical details on shutdown procedures, firmware updates, hardware instructions.

TZ67-F
TKB Home TZ67-F
25.05.2026 3 pages

TKB_TZ67-F Z-Wave Wall Plug Dimmer for Typ F Firmware Version : 1.4 Quick Start A This is a Z-Wave actuator. Inclusion and Exklusion are confirmed by hitting th Instruction reference guide for the TKB Home TZ67-F Home Automation. The documentation guides users through setup and service contacts, shutdown procedures, firmware updates, technical guidelines.

TZ69
TKB Home TZ69
19.07.2026 2 pages

The product supports Over The Air(OTA) feature for the products firmware upgrade. 2990W for TZ69E, 3000W for TZ69G/TZ69F, 2200W for TZ69C/ TZ69CN,2500W for TZ69 Instruction and usage manual for the TKB Home TZ69 Home Automation. The manual outlines system configuration and user instructions, network configuration, performance guidelines.

TZ79
TKB Home TZ79
07.06.2026 2 pages

-1- This insert switch module in a transceiver which is a Z-Wave enabled device and is fully compatible with any Z-Wave enabled network. Z-Wave enabled devices Full technical guide for the TKB Home TZ79 Switch. The document highlights operating procedures and installation procedures, warranty information, reset instructions, maintenance schedule.

Similar Manuals in the Thermostat Category

D538
Tekmar D538
14.04.2026 24 pages

Complete instruction guide for the Tekmar D538 Thermostat. This guide presents instructions on setup tips, error handling, adjustment procedures.

RLV4300
Honeywell RLV4300
15.04.2026 20 pages

Owner’s Manual Read and save these instructions. For help please visit yourhome.honeywell.com RLV4300  5-2 Programmable Thermostat Application This thermosta Installation reference manual for the Honeywell RLV4300 Thermostat. This documentation explains configuration and product maintenance, calibration steps, device reset instructions.

SMT-101
Smart temp SMT-101
05.05.2026 2 pages

General Description Operation Smart Temp The SMT-101 is programmable heating only thermostat designed for gas heating or Hydronic heating systems. It is easy t Official operating instructions for the Smart temp SMT-101 Thermostat. It covers topics such as safety, network setup, security instructions, operational procedures.

VITOTROL 100
Viessmann VITOTROL 100
10.04.2026 16 pages

Installation and service instructions for contractors VIESMANN Vitotrol 100 Type UTA Room thermostat for the Vitotronic 100 For applicability, see the last page Complete technical documentation for the Viessmann VITOTROL 100 Thermostat. It explains configuration options and safety, usage tips, operational safety.