TORK Lighting Reactivation Switch Model: LDSH, LDSH-A INSTALLATION AND USER’S GUIDE FUNCTION & DESCRIPTION The Lighting Delay Switch is an accessory to any TORK maintained contact time switch and is used to extend the time on of lighting, HVAC, and other main building loads after the time switch turns OFF. An auxiliary contact closes, turning on a user select- ed signal device (i.e. bell, horn, light, or other warn- ing device), which turns off at the end of the user selected 4 second, 1 minute or 5 minute period. Remote momentary ON/OFF push button switch- es can be connected to the designated terminal of the Lighting Delay Switch using low voltage #18 - 22 AWG twisted pair wires. Pressing the remote ON button momentarily during a 1 or 5 minute warning period will extend the time on (main load) for a user selectable 1/2 hour, 1 hour, 1-1/2 hour, 2 hours, 6 hours, 9 hours, or 12 hours. At the end of the extended time the user selected signal device will again turn on, allowing personnel to repeat another 1/2 - 12 hour extension of the main load if necessary. Pressing the remote OFF button for 3 to 4 seconds will terminate the extension of time for the main load, and turn on the auxiliary warning circuit. The warning circuit will turn OFF after the 4 second, 1 minute or 5 minute period. The main load will turn off after 1 or 5 minutes (user selectable). When starting up after a power failure (if time switch is not ON), the main load will be turned ON for 10 minutes. At the end of the 10 minute period, the warning circuit will turn on. The main load will remain ON for the 1 or 5 minute warning period. If an extension of time is required for the main load, press the remote ON button momentarily. The auxiliary warning circuit will turn off, and the main load will remain on for an additional 1/2 - 12 hour extension of time. This unit is ideally suited to meet Energy Conservation construction codes relative to con- trolled lighting after hours and assures building loads will go OFF after personnel (i.e. cleaning- staff working after hours) leave the building. NOTE: 1. Multiple remote momentary push buttons may be wired to the same terminals for access from dif- ferent locations. 2. The Lighting Delay Switch can be operated as a stand alone control using remote ON/OFF momentary push-buttons. 3. If time of day control is also required, see wiring diagram for time switch interface. A. Pressing the remote ON momentary push-but- ton while the time switch is ON will start the internal timer of the Lighting Delay Switch, but will have no immediate impact on the main load. When the time switch turns OFF, the load will remain ON for the duration left on the LDSH. B. Pressing the remote OFF push button for 3 to 4 seconds while the time switch is ON will termi- nate the internal timer of the Lighting Delay Switch, but will have no impact on the main load which will remain ON. When the time switch turns OFF, the load will turn OFF after the warning period. INSTALLATION PROCEDURE Step 1: Model LDSH only. Remove the unit from the plastic track. Mount the plastic track with provided hardware only. Do not use other hardware. Snap the unit back into the track. Step 2: Before wiring, power to this unit, the time switch, and the equipment it controls must be turned off at the main panel. Wire the unit according to the appropriate wiring diagrams provided. Be sure to follow local and all other codes. Step 3: Set all switches #1, 2, 3, and 4 to the ON position for test. This will accelerate the complete opera- tion of the unit to under 1 minute, allowing a check of the wiring and the functions. Step 4: Set the extended time delay for the main load to the appropriate time by adjusting switch #1, 2, and 3. See table for desired timing.

LDSH: Related Instructions

EW101
Tork EW101
02.07.2026 3 pages

TORK EW101/EW103/EW120 7 DAY Digital Time Switch READ INSTRUCTIONS CAREFULLY BEFORE SETTING UNIT INSTALLATION UNIT IS TO BE INSTALLED BY A LICENSED ELECTRICIAN Product documentation for the Tork EW101 Switch. The documentation includes supported accessories, assembly reference, operating guidelines, technical troubleshooting.

Express 460004
Tork Express 460004
06.06.2026 5 pages

REVISIONS REV. DESCRIPTION ECN DATE N/A SCA GLOBAL HYGIENE CATEGORY DATE SHEET SCALE PROJECTION FIRST ANGLE 1:1 STATE PREVIOUS PART NUMBER SIZE PROPRIETARY AND Practical user guide for the Tork Express 460004 Dispenser. It offers details on safety protocols, compatibility information, regulatory notices.

Performance W4 Series
Tork Performance W4 Series
01.04.2026 8 pages

Washroom Dispenser Service and Parts Manual Tork Performance W4 Folded Wiper/Cloth Dispenser 654021; 6540281 Revision Date: 6-19-17 1 of 8 Tork Performance Fold Manual for safe operation of the Tork Performance W4 Series Bathroom Fixtures. The documentation includes details on operating guidelines, setup instructions, backup procedures.

6521281
Tork 6521281
11.05.2026 8 pages

Washroom Dispenser Service and Parts Manual Tork Performance W1 Wiper Wall Mount Dispenser 6521281 Revision Date: 12-19-14 1 of 8 Tork Performance Wiper Wall M Professional manual for the Tork 6521281 Dispenser. The document highlights operating procedures and operating instructions, calibration steps, backup procedures, repair references.

LDS
Tork LDS
26.03.2026 4 pages

TORK Lighting Delay Switch Model: LDS, LDS-A INSTALLATION AND USER’S GUIDE FUNCTION & DESCRIPTION The Lighting Delay Switch is an accessory to any TORK mainta Operating instructions for the Tork LDS Switch. This guide offers instructions on technical guidelines, performance guidelines, product specifications, basic operation.

571020A
Tork 571020A
24.03.2026 5 pages

Washroom Dispenser Service and Parts Manual Tork Foam Soap Manual Dispenser 571020A (White) - 571028A (Black) Revision Date: 5-19-09 Tork Manual Foam Soap Disp Official user manual for the Tork 571020A Dispenser. It includes maintenance procedures and operational procedures, device safety checks, installation guides, maintenance guidelines.

Similar Manuals in the Switch Category

TE100-S5P+
TRENDnet TE100-S5P+
21.07.2026 15 pages

Copyright ©2005. All Rights Reserved. TRENDware International, Inc. TRENDnet TRENDware, USA What's Next in Networking TE100-S5P+/TE100-S8P/TE100-S55E+ TE100-S Official operating instructions for the TRENDnet TE100-S5P+ Network Router. This guide offers instructions on product specifications, user settings, technical troubleshooting.

GS-5220-16S8C
Planet GS-5220-16S8C
11.07.2026 353 pages

User’s Manual of GS-5220-16S8C & GS-5220-16S8CR 1 User reference guide for the Planet GS-5220-16S8C Switch. The document contains connectivity setup, repair references, performance optimization.

DG-GO4300 Series
Digisol DG-GO4300 Series
14.06.2026 90 pages

DG-GO4300 Series OLT USER MANUAL (WEB Management) V2.0.1 19-04-2019 As our products undergo continuous development the specifications are s Quick start guide for the Digisol DG-GO4300 Series Switch. The manual provides information on product safety, safety precautions, software configuration.

VEGACAP 63
Vega VEGACAP 63
27.08.2026 16 pages

Supplementary instructions Float for oil/water detection for VEGACAP 63 Document ID: 31595 Capacitive Installation reference manual for the Vega VEGACAP 63 Measuring Instruments. The manual includes instructions for system configuration, installation steps, operating modes.