SPECIFICATIONS Range: –100.00 to 199.99°C (6410) –100.00 to 70.00°C (6411) Update Rate: 1 second Battery: 2 each AAA (1.5V) Probe: Waterproof, platinum RTD stainless-steel probe, 0.13" dia.; stem: 9"; overall: 12", 10-foot PVC cable SETTING THE TIME-OF-DAY/DATE Slide the DISPLAY switch to the DATE/TIME position, the display will show the time-of-day and date. Place your thumb on the middle of the front of the unit and slide the top cover down to expose the controls (see image above). While in the time-of-day/date display, pressing the SELECT button or ADVANCE button will allow the date and time to be set. Pressing the SELECT button will cause the digits to flash in the following order Year→Month→Day→Hours→ Minutes →12/24 hour time→No digits flashing (value set). Once the desired item is flashing, pressing the ADVANCE button will increment the value. Press and hold the ADVANCE button for <3 seconds for continuous incrementation. With the desired time-of-day/date appearing on the display, press the SELECT button until no digits are flashing on the display. The time-of-day/date will be saved. While in the time-of-day/date display, pressing the EVENT DATE/TIME button will switch the date display between Month/ Day (M/D) and Day/Month (D/M) display modes. Note: While in the time-of-day/date setting mode, if no button is pressed for fifteen (15) seconds, the unit automatically exits from the setting mode. All digits will stop flashing to indicate setting mode has been exited. VIEWING THE TIME-OF-DAY/DATE To view the time-of-day/date, slide the DISPLAY switch to the DATE/TIME position. DISPLAYING °F OR °C To display the temperature readings in Fahrenheit or Celsius, slide the °C/°F switch to the desired position. MINIMUM AND MAXIMUM MEMORY The minimum temperature recorded into memory is the minimum temperature achieved since the last time the memory was cleared. The maximum temperature recorded into memory is the maximum temperature achieved since the last time the memory was cleared. Minimum and maximum temperature memories are NOT programmable (see HI/LO ALARMS). Below are the FOUR different memory features: • MIN/MAX: Minimum (MIN) and maximum (MAX) tempera- ture achieved with time-of-day and date occurred since the last time the memory was cleared. –AND– • 24-HOUR: Minimum (MIN) and maximum (MAX) tempera- ture achieved for each hour within a 24-hour period. • 7-DAY: Minimum (MIN) and maximum (MAX) temperature achieved for each day within a 7-day period. –OR– • 31-DAY: Minimum (MIN) and maximum (MAX) tempera- ture achieved each day during a 31-day period and the time-of-day it occurred. TO TOGGLE BETWEEN 31-DAY AND 24-HOUR/7-DAY MEMORY MONITORING MODES 1. Slide the ‘DISPLAY’ switch to the MIN/MAX position. 2. Slide the ‘HISTORY” switch to the ON position. 3. Press the ‘EVENT DATE/TIME’ button 3 times. The LCD will display the current history mode. 4. To toggle to the other mode press the ‘SELECT’ button. The LCD will change the display to the new history mode. TO VIEW THE MINIMUM/MAXIMUM MEMORY 1. Slide the DISPLAY switch to the ‘MIN/MAX’ position. 2. Press the ‘EVENT DATE/TIME’ once to view the minimum temperature achieved during the most recent monitoring period and the time/date it occurred. 3. The next press of the ‘EVENT DATE/TIME’ button will dis- play the maximum temperature achieved during the most recent monitoring period and the time/date it occurred. 4. Holding the ‘EVENT DATE/TIME’ button continuously for 2 seconds or no button press for 15 seconds will return the display to the default min/max screen. CLEARING THE MINIMUM/MAXIMUM MEMORY 1. Slide the ‘DISPLAY’ switch to the MIN/MAX position. The display will show the current temperature and mini- mum/maximum memory. 2. Press the ‘CLEAR MIN/MAX’ button to clear the minimum and maximum memories. TO VIEW 24-HOUR MIN/MAX MEMORY (24-hour file) 1. Slide the ‘DISPLAY’ switch to the ‘MIN/MAX’ position. 2. Slide the ‘HISTORY’ switch to the ‘ON’ position. 3. Slide the ‘PERIOD’ switch to the ‘HR’. 4. Press the ‘EVENT DATE/TIME’ button three times to begin viewing the hourly data. The LCD will display the current history viewing mode. 5. The next press of the ‘EVENT DATE/TIME’ button will display the minimum temperature achieved during the current hour. 6. Press the ‘EVENT DATE/TIME’ button again to view the maximum temperature achieved during the current hour. 7. Each subsequent press of the ‘EVENT DATE/TIME’ button will display an hourly minimum or maximum temperature reading for the previous hourly periods in descending chronological order. 8. Once all saved readings have been viewed, the display will return to the default min/max screen. 9. Holding the ‘EVENT DATE/TIME’ button continuously for 2 seconds or no button press for 15 seconds will return the display to the default min/max screen. NOTE: All data for the 24-hour file will be lost when the mem- ory is toggled to the 31-day file. Also, all data for the 7-day file will be lost when the memory is toggled to the 31-day file. CLEARING THE 24-HOUR MINIMUM/MAXIMUM MEMORY 1. Slide the ‘DISPLAY’ switch to the MIN/MAX position. The display will show the current temperature and mini- mum/maximum memory. 2. Slide the ‘PERIOD’ switch to ‘HR’. 3. Press the ‘EVENT DATE/TIME’ button three times to view the memory data. 4. Press ‘CLEAR MIN/MAX’ to clear the memory data. Note: Clearing the 24-hour MIN/MAX will NOT clear the 7-day MIN/MAX. TO VIEW 7-DAY MIN/MAX MEMORY (7-day file) 1. Slide the ‘DISPLAY’ switch to the ‘MIN/MAX’ position. 2. Slide the ‘HISTORY’ switch to the ‘ON’ position. 3. Slide the ‘PERIOD’ switch to the ‘DAY’. 4. Press the ‘EVENT DATE/TIME’ button three times to begin viewing the daily data. The LCD will display the current history viewing mode. 5. The next press of the ‘EVENT DATE/TIME’ button will display the minimum temperature achieved during the current day. 6. Press the ‘EVENT DATE/TIME’ button again to view the maximum temperature achieved during the current day. 7. Each subsequent press of the ‘EVENT DATE/TIME’ but- ton will display a daily minimum or maximum temperature reading for the previous 7-day period in descending chronological order. 8. Once all saved readings have been viewed, the display will return to the default min/max screen. 9. Holding the ‘EVENT DATE/TIME’ button continuously for 2 seconds or no button press for 15 seconds will return the display to the default min/max screen. CLEARING THE 7-DAY MINIMUM/MAXIMUM MEMORY 1. Slide the ‘DISPLAY’ switch to the MIN/MAX position. The display will show the current temperature and mini- mum/maximum memory. 2. Slide the ‘PERIOD’ switch to ‘DAY’. 3. Press the ‘EVENT DATE/TIME’ button three times to view the memory data. 4. Press ‘CLEAR MIN/MAX’ to clear the memory data. Note: Clearing the 7-daily MIN/MAX will NOT clear the 24-hour MIN/MAX. TO VIEW 31-DAY MIN/MAX MEMORY (31-day file) 1. Slide ‘DISPLAY’ switch to the ‘MIN/MAX’ position. 2. Slide the ‘HISTORY’ switch to the ‘ON’ position. 3. Press the ‘EVENT DATE/TIME’ button 3 times. The LCD will display the current memory mode. 4. The next press of the ‘EVENT DATE/TIME’ button will display the minimum temperature achieved during the current day. 5. Press the ‘EVENT DATE/TIME’ button again to view the maximum temperature achieved during the current day. 6. Each subsequent press of the ‘EVENT DATE/TIME’ but- ton will display a daily minimum or maximum temperature reading for the previous 31-day period in descending chronological order. 7. Once all saved readings have been viewed, the display will return to the default min/max screen. 8. Holding the ‘EVENT DATE/TIME’ button continuously for 2 seconds or no button press for 15 seconds will return the display to the default min/max screen. CLEARING THE 31-DAY MINIMUM/MAXIMUM MEMORY 1. Slide the ‘DISPLAY’ switch to the MIN/MAX position. The display will show the current temperature and mini- mum/maximum memory. 2. Press the ‘EVENT DATE/TIME’ button three times to view the 31-day memory. 3. Press ‘CLEAR MIN/MAX’ to clear the memory data. HI/LO ALARMS Alarm limits may be set in 0.1° increments. With the alarm switch set to the ON position: - The unit will sound an alarm and flash the LEDs when the temperature measured is outside the alarm limits that have been set (equal to or lower than the low alarm set point, or equal to or greater than the high alarm set point). - The alarm will sound regardless of the display mode. SETTING THE TEMPERATURE ALARM LIMITS 1. Slide the DISPLAY switch to the ALARM position. The display will show the current temperature and low/ high alarm set points. 2. While in the alarm display mode, pressing the ‘SELECT’ button will allow the alarm limits to be set. Pressing the SELECT button will cause the digits to flash in the following order: Low Alarm 1st Digits→Low Alarm 2nd Digit→Low Alarm Decimal Digit→ High Alarm 1st Digits→High Alarm 2nd Digit→High Alarm Decimal Digit→No digits flashing (value set). 3. Once the desired item is flashing, pressing the ADVANCE button will increment the value. 4. With the desired alarm set points appearing on the dis- play, press the SELECT button until no digits are flashing on the display. The alarm settings will be saved.
Traceable PLATINUM Instructions [PDF] (2 pages)
- Identifier: id-2292028
- Brand: Traceable
- Device: Traceable PLATINUM Thermometer
- Type: Instructions, PDF
- Key Aspects: Component Longevity Optimization, Information on Regular Maintenance, Initial Startup Checklist
- UPD Date: 23.08.2026
- Source File: 1995597.pdf
- Pages: 2
- Description: Complete technical documentation for the Traceable PLATINUM.
Pages Preview:
Document Preview & Text Transcription (Main Page)
Click to expand and read text
RECALL MINIMUM/MAXIMUM 1.� Press�MIN/MAX�to�view�the�minimum�and�maximum � temperatures�recorded�since�turning�the�unit�on�or � since�clearing�min/max. 2.� Press�the�MIN/MAX�button�once�to�display�the � minimum�temperature.�The�lower�portion�of�the � display�shows�“MIN”�indicating�that�this�is�the � minimum�reading.�While�in�the�MIN/MAX�mode, � select�the�desired�format�with�the�°F/°C�or � .0/.00/.000/.0000�buttons. 3.� Press�the�MIN/MAX�button�again�to�display�the � Maximum�temperature.�The�lower�portion�of�the � display�shows�“MAX”�indicating�that�this�is�the � maximum�reading.�A�third�press�will�return�the� � display�to�the�current�reading. 4.� MIN/MAX�may�be�reviewed�at�any�time. 5.� To�clear�the�MIN/MAX,�place�the�unit�in�normal�mode � (not�reviewing�the�MIN/MAX)�and�press�MIN/MAX � and�CLEAR�simultaneously.�You�may�also�clear� � MIN/MAX�by�turning�the�unit�off. HOLD FUNCTION 1.� Press�the�HOLD�button�once�to�“freeze”�the�display � at�the�current�temperature�reading.�“HOLD”�appears � on�the�lower�portion�of�the�display�indicating�that�the � unit�is�in�hold�mode. 2.� While�in�the�HOLD�mode,�select�the�desired�format � with�the�°F/°C�or�.0/.00/.000�buttons. 3.� Press�the�HOLD�button�a�second�time�to�return�to � the�current�temperature�reading.�“HOLD”�will�no � longer�appear�on�the�display. POWER Do�not�turn�the�unit�on�and�off�rapidly.�It�may�lock�the� display.�When�turning�the�unit�on/off�the�microprocessor� may�become�locked,�inoperable,�or�the�display�may� read�“888888.”�If�this�occurs,�reset�the�thermometer�by� removing�the�battery,�waiting�15�seconds,�and�replacing� the�battery. OPERATION 1.� Plug�the�probe�into�the�receptacle�located�on�the�right � side�of�the�unit. 2.� Press�the�ON/OFF�button�to�turn�the�unit�on. 3.� Press�the�°F/°C�button�to�change�the�display� � between�Fahrenheit�and�Celsius. 4.� Press�the�.0/.00/.000/.0000�button�to�change�the � display�to�read�the�desired�resolution. 5.� Use�the�probe�to�monitor�temperatures�in�air/gas, � liquids,�and�semi-solids.�Place�the�stainless-steel� � portion�of�probe�in�contact�with�the�material�to�be � measured.�In�most�instances�the�depth�of�the�probe � needs�to�be�approximately�½�inch.� 6.� Press�the�ON/OFF�button�to�turn�the�unit�off�when�the � thermometer�is�not�in�use�to�prolong�battery�life. HISTORY MODE History�provides�an�effortless�method�to�observe�when�a� temperature�change�takes�place.��It�continuously�displays� for�the�past�24�hours�starting�with�1�hour�ago.�If�left�on�for� more�than�24�hours,�it�displays�only�the�most�recent�24� hours.�History�may�be�reviewed�at�any�time. 1.� After�1�hour,�press�the�HISTORY�button�once�to� � show�the�current�or�first�hour�reading.�The�display � will�show�“1”�on�the�far�right�to�indicate�this�is�the�first � reading.�After�approximately�two�seconds,�the�display � will�show�the�temperature�and�“min”�which�indicates � this�is�the�minimum�reading�for�the�first�hour.��After � approximately�two�more�seconds,�the�display�will � again�show�“1”.�The�display�continues�to�alternate � between�these�two�displays.�While�in�the�history � mode,�the�°F/°C�or�.0/.00/.000�buttons�may�be�used � to�select�the�desired�format. 2.� The�second�press�of�the�HISTORY�button�shows�the � maximum�temperature�for�the�current�or�first�hour. � After�approximately�two�more�seconds,�the�display � will�show�“1”. 3.� With�each�press�of�the�HISTORY�button,�the�unit� � will�scroll�through�all�48�minimum�and�maximum � readings. 4.� To�exit�the�history�mode,�press�the�CLEAR�button� � or�MIN/MAX�button.��As�long�as�the�unit�is�in�the � history�mode,�pressing�the�CLEAR�button�alone�will � not�clear�the�history. 5.� To�clear�history,�first�exit�the�history�mode�and�then � press�HISTORY�and�CLEAR�buttons�simultaneously. � Turning�the�unit�off�does�not�clear�the�history. SPECIFICATIONS Range:� -328.00�to�932.000°F�� � -200.00�to�500.000°C Resolution:� 0.001°,�0.01°�or�0.1°� (user�selectable)� from�-99�to�932°F/-99�to�500°C � 0.01°�or�0.1° � from�-328�to�-100°F/-200�to�-100°C � 0.0001°�from�-9.9999�to�99.9999�°F/°C Sampling Rate:� approximately�2�times�per�second Memories:� 48�Memories�are�stored�in�the�History � Mode�(min/max�for�the�past�24�hours) � 2�Memories�are�stored�in�the�Min/Max � Mode�(min/max�for�the�current�hour) Probes Supplied:� Model 6412�supplied�with�a�fast�response,�handle-probe.�� The�stainless�steel�portion�of�the�probe�is�capable�of� measuring�temperatures�through�the�entire�range�(-328�to� 932°F/-200�to�500°C) Model 6413�supplied�with�a�fast�response,�bullet-probe� with�PTFE�cable.��The�sensor�and cable�are�capable�of� being�subjected�to�temperatures�of�-148�to�392°F/-100� to�200°C BUTTON DESCRIPTION ON/OFF� Turns�unit�on�and�off. °F/°C:� Selects�°Fahrenheit/°Celsius .0/.00/.000/.0000� Selects�decimal�point�on�display HISTORY� Displays�history�memories HOLD/CLEAR� Press�to�hold�reading�also�used�in � � conjunction�with�HISTORY�or� � � MIN/MAX�buttons�to�exit�the�mode�or � � clear�readings. MIN/MAX� Displays�the�highest�and�lowest � � temperatures�recorded�for�the�current � � hour. DISPLAY MESSAGES ▲�Appearing�indicates�temperature�is�rising.� ▼�Appearing�indicates�temperature�is�falling. “LLL” Displayed�when�the�temperature�being� � � measured�is�below�the�range�of�the�unit�or�when � � there�is�an�open�probe�or�no�probe. “HHH”��Displayed�when�the�temperature�being � � measured�is�above�the�range�of�the�unit�or � � when�there�is�a�shorted�probe. “BAT” Displayed�when�the�battery�is�low�and�needs�to � � be�replaced.�See�Battery�section�for�battery � � replacement�instructions. RECEPTACLES The�receptacle�on�the�right�side�of�the�unit�is�for�the� probe.�The�upper�left�side�receptacle�is�for�an�accessory� AC�Adaptor.��The�lower�left�side�receptacle�is�for�the� accessory�Data�Acquisition�System�data�cable. DATA OUTPUT In�order�to�use�the�data�output,�the�Accessory Data Cable Cat No. 4099�is�required.�See�Accessories�section� for�ordering�information. With�the�accessory�data�cable�attached,�to�toggle�the� RS232�output�on/off,�press�and�hold�the�°F/°C�and� .0/.00/.000/.0000�simultaneously�(2320�indicates� RS232�output�is�“on”,�232F�indicates�RS232�output� is�“off”). BATTERY If�“BAT”�appears�on�the�display,�it�indicates�the� batteries�are�low�and�need�to�be�replaced.�To�replace� the�battery,�slide�the�battery�cover�located�on�the�back� of�the�unit�away�from�the�unit.�Remove�the�old�battery� and�replace�it�with�a�new�9-Volt�alkaline�battery.�Use�an� alkaline�battery,�NOT�a�regular�or�heavy�duty�battery.� Properly�connect�the�battery.�Replace�the�battery�cover.� Incorrectly�installed�batteries�may�damage�electronics. ALL OPERATIONAL DIFFICULTIES If�this�thermometer�does�not�function�property�for�any� reason�please�replace�the�battery�with�a�new�9-Volt� alkaline�battery�Battery�section,�above).�Low�battery� power�can�occasionally�cause�any�number�of�“apparent”� operational�difficulties.�Replacing�the�battery�with�a�new� fresh�battery�will�solve�most�difficulties.
Similar Manuals in the Thermometer Category
| Device Model | Type of Document | Pages | Size | Views | Downloads | Updated | All Manuals for Device |
|---|---|---|---|---|---|---|---|
Exergen TAT-2000C |
TAT-2000C Instructions for use & warranty - 46DY34 |
2 | 955 | 153 | 05-04-2026 | view all manuals | |
AEMC CA879 |
#11TS25: CA879 Thermometer Operation & user’s manual |
13 | 168 | 27 | 21-05-2026 | view all manuals | |
Digoo DG-TH3330 |
#H8SS27: DG-TH3330 Thermometer Quick start manual |
2 | 687 | 165 | 17-08-2026 | view all manuals | |
Comper Smart Fertility Tracker |
Comper Smart Fertility Tracker Manual (Manual ), @81K559 |
30 | 1336 | 228 | 21-08-2026 | view all manuals | |
Omega Engineering OS550 Series |
Thermometer #DSSDV1 |
77 | 505 | 76 | 19-07-2026 | view all manuals | |
Youshiko YC9080 |
Youshiko YC9080 Manual (Operation & user’s manual), @11HDA6 |
7 | 760 | 145 | 08-08-2026 | view all manuals |