Trane THV1M087A936SA Manuals
2 pdf manual(s) Trane THV1M087A936SA for free download (Document Types: Service facts, Installer's manual)
Trane THV1M087A936SA Service facts [PDF] (12 pages)
- Identifier: id-2290586
- Brand: Trane
- Device: THV1M087A936SA Furnace
- Type: PDF
- Key Aspects: System Limitations and Considerations, Additional Modules and Accessories Guide, Environmental Factors and Restrictions
- UPD Date: 01.07.2026
- Source File: 1997039.pdf
- Pages: 12
- Description: Quick reference guide for the Trane THV1M087A936SA.
Click to expand and read text
Service Facts © 2009 Trane All Rights Reserved NOTICE: Since the manufacturer has a policy of continuous product and product data improvement, it reserves the right to change design and specifications without notice. IMPORTANT — This document contains a wiring diagram and service information. This is customer property and is to remain with this furnace. Please return to service information pack upon completion of work. DISCONNECT POWER BEFORE SERVICING WARNING OIL FIRED CENTRAL FURNACE THV1M087A936 - 948SA, TLF1M087A936 - 948SA TLR1M087A936 - 948SA, TDF1M087A936 - 948SA Oil Fired Furnace Specifications Model THV1M087A936 & 948SA TLF1M087A936 & 948SA TLR1M087A936 & 948SA TDF1M087A936 & 948SA Type Upflow - Highboy Upflow - Lowboy Downflow - Horizontal Heat input Rate (BTUH): 140,000 119,000 105,000 84,000 140,000 119,000 105,000 84,000 140,000 119,000 105,000 84,000 Nominal Thermal Efficiency (%): 83.6 84.2 83.8 Heating Capacity (BTUH): 114,000 98,000 87,000 70,000 114,000 98,000 87,000 70,000 114,000 98,000 87,000 70,000 Nominal Temperature Rise (deg. F): 85 85 85 Minimum AFUE (I.C.S.) Rating (%): THV1M087A936SA - 82.9% THV1M087A948SA - 82.6% TLF1M087A936SA - 82.9% TLF1M087A948SA - 82.7% TLR1M087A936SA - 85.0% ** TLR1M087A948SA - 82.4% TDF1M087A936SA - 84.8% TDF1M087A948SA - 82.6% Burner Specifications: R.W. Beckett Pressure Atomizing Type, Model AF R.W. Beckett Pressure Atomizing Type, Model AF R.W. Beckett Pressure Atomizing Type, Model AF Air Tube Length (in.): 5.875, Effective 5.875, Effective 5.875, Effective Burner Head Type: Fixed, Flame Retention Fixed, Flame Retention Fixed, Flame Retention Fuel Type: # 2 Distillate (Domestic Heating Oil) # 2 Distillate (Domestic Heating Oil) # 2 Distillate (Domestic Heating Oil) Nozzle Rating For Beckett AF (GPH): 1.00 0.85 0.75 0.60 1.00 0.85 0.75 0.60 1.00 0.85 0.75 0.60 Spray Angle (deg.): 80 80 80 Spray Pattern: Hollow Hollow Hollow Oil Pump Pressure (PSIG): 130 130 130 Ignition Control Type: Interrupted, Direct Spark Interrupted, Direct Spark Interrupted, Direct Spark Pre / Post Purge Feature(s): Yes / no Yes / no Yes / no Automatic Oil Solenoid Valve: Yes Yes Yes Blower Drive: Direct Direct Direct THV1M087A936SA THV1M087A948SA TLF1M087A936SA TLR1M087A936SA TLF1M087A948SA TLR1M087A948SA TDF1M087A936SA TDF1M087A948SA Diameter x Width (in.): 10 x 9 11 x 11 10 x 9 10 x 9 10 x 9 11 x 9 No. Used: 1 1 1 1 1 1 Speeds (no.): 4 4 4 4 4 4 CFM vs in. w.g.: See Fan Performance Table See Fan Performance Table See Fan Performance Table Motor HP: 1/2 3/4 1/2 3/4 1/2 3/4 R.P.M.: 1075 1130 1075 1130 1075 1130 Volts / Ph. / Hz.: 120 / 60 / 1 120 / 60 / 1 120 / 60 / 1 Filter Furnished?: Yes Yes No Type Recommended: Throwaway Throwaway Throwaway No. - Size x Thick: 1 - 16 x 25 x 1 2 - 10 x 20 x 1 Not Supplied Vent - Size (in.): 6 6 6 Gross Heat Exchanger Area (sq. ft.): 27.8 27.8 (Front Flue) / 30.0 (Rear Flue) 27.8 Suply / Return Size (in. x in.): See Outline Drawing See Outline Drawing See Outline Drawing Combustion Chamber Type: Preformed, Refactory (Ceramic Fiber Matrix Material) Preformed, Refactory (Ceramic Fiber Matrix Material) Preformed, Refactory (Ceramic Fiber Matrix Material) Total Current (amps.): 12.1 19.8 12.1 19.8 12.1 19.8 Max. Fuse Size (amps.): 15 30 15 30 15 30 Dimensions uncrated (in.): H X W X D 58 X 22.25 X 31 H X W X D 41.5 X 22.25 X 47 H X W X D 22.25 X 61.25 X 22.25 Weight Shipping (lbs.) / Net (lbs.) 260 / 250 300 / 290 280 / 270 ** Energy Star OFF-SF-1B AVAILABLE IN FRENCH CANADIAN (FC)
Trane THV1M087A936SA Installer's manual [PDF] (24 pages)
- Identifier: id-1379332
- Brand: Trane
- Device: THV1M087A936SA Furnace
- Type: PDF
- Key Aspects: Component Longevity Optimization, Performance Optimization Tips, Pre-Deployment Preparation Steps
- UPD Date: 20.06.2026
- Source File: 1348422.pdf
- Pages: 24
- Description: Installation guide for the Trane THV1M087A936SA.
Click to expand and read text
MO-508 ECN 5396-MA 141211 THV1M087A936, 948, 9V3, 9V5SA - Highboy TLF1M087A936, 948, 9V3, 9V5SA- Lowboy Front Flue TLR1M087A936, 948, 9V3, 9V5SA - Lowboy Rear Flue TDF1M087A936, 948, 9V3, 9V5SA - Downflow/ Horizontal OIL FIRED CENTRAL FURNACE ALL phases of this installation must comply with NATIONAL, STATE AND LOCAL CODES IMPORTANT — This Document is customer property and is to remain with this unit. Please return to service information pack upon completion of work. Installer’s Guide THV1 Highboy Vertical Flue TLF1 Lowboy Front Flue TLR1 Lowboy Rear Flue TDF1 Downflow/ Horizontal Front Flue
THV1M087A936SA: Related Instructions
Supplementary Electric Heaters for JMM4&5 Wall-Mount Air Handlers INSTALLER'S GUIDE Models: BAYHTRJ505BRKAA BAYHTRJ508BRKAA BAYHTRJ510BRKAA IMPORTANT — This D Device setup guide for the Trane OXBOX BAYHTRJ505BRKAA Electric Heater. The guide explains setup and product specifications, troubleshooting tips, hardware setup, device operation tips.
Installation Operation Maintenance July 2007 GHND-SVX01A-EN GHND GHPD High Efficiency Propeller Fan Gas Unit Heater Full technical guide for the Trane GHND-SVX01A-EN Gas Heater. The document covers system parameters, safety information, network configuration, operational guidelines.
SAFETYWARNING Only qualified personnel should install and service the equipment.The installation, starting up, and servicing of heating, ventilating, and air-co Official user handbook for the Trane SEHJ090-162 Air Conditioner. The manual outlines technical specifications and service instructions, installation guides, device overview, product safety.
SSAAFFEETTYY W WAARRNNIINNGG Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventila Technical operations guide for the Trane S8B1A026M2PSAB Furnace. This guide offers instructions on diagnostic information, repair references, safety protocols, operating guidelines.
Variable Speed, 2-Stage Communicating or 24V Upflow / Horizontal and Downflow / Horizontal, Gas-Fired Furnaces, “Fan Assisted Combustion System” A341789P11 Comprehensive guide for the Trane UD2B060ACV32A Series Furnace. This manual provides guidance on performance details, setup instructions, safety information.
SSAAFFEETTYY W WAARRNNIINNGG Only qualified personnel should install and service the equipment. The installation, starting up, and servicing of heating, ventila Manual for installation and usage of the Trane Foundation GBC180 Air Conditioner. This documentation highlights features and technical overview, setup validation, control functions.
Similar Manuals in the Furnace Category
User instructions for the Goodman GCVM960604CXA Furnace. This reference includes backup procedures, troubleshooting tips, safety.
����� �������� �������� ���������� �������� ������ ������� Instruction reference guide for the Lennox G60DF series Furnace. It covers topics such as setup guidelines, product safety, replacement parts.
NTC7/G N L - Upflow/Horizontal NDC7/G DL - Downflow Series SAFETY CONSIDERATIONS /X Recognize safety information. This is the safety-alert symbol _. When you se Official user manual for the ICP NTC7/GNL Series Furnace. The manual outlines system configuration and device overview, user preferences, troubleshooting, service contacts.
507868-02 Page 1 of 48 Issue 2128 INSTALLATION INSTRUCTIONS A93DF1E & 92G1DFE Warm Air Gas Furnace Downflow Air Discharge Save these instructions for future ref Complete service manual for the Allied Air A93DF1E Furnace. This documentation explains configuration and product specifications, interface navigation, device instructions.