Unless otherwise indicated, the distances listed are the typical maximum cable
distance. The actual maximum cable distances are dependent upon the physical
characteristics of the network installation.
** Minimum Cable Distance:
2 meters
Typical Maximum Cable Distance:
220 meters for 160/500MHz•Km
270 meters for 200/500MHz•Km
CFMFF13xx-28x
User’s Guide
Single Mode to Multimode Retiming Media
Converter
• Slide-in-Module Media Converter
• Gigabit Ethernet
Transition Networks CFMFF13xx-28x series media
converters extend multimode interfaces over gigabit
Ethernet fiber optic cable. The CFMFF13xx-28x is also
designed to be installed into the Transition Networks
PointSystem™ chassis.
Unlike most gigabit Ethernet media converters, which allow only two media
converters in series, the CFMFF13xx-28x has a retiming/reshaping feature that
makes it possible to connect any number of media converters in series.
Part Number
Port One - Duplex Fiber Optic
1000Base-SX
Port Two - Duplex Fiber-Optic
1000Base-LX
CFMFF1314-280
SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm single mode
10 km (6.2 miles)
CFMFF1315-280
SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm single mode
25 km (15.5 miles)
CFMFF1317-280
SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm single mode
65 km (40.3 miles)
CFMFF1324-280 SC, 850 nm multimode
220 m (721 ft)**
SC, 1300 nm multimode
(1000Base-SX) 2 km (1.2 miles)
(62.5 / 125 mm fiber only)
CFMFF1335-280
SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm single mode
125 km (77.5 mi)
CFMFF3535-280
SC, 1550 nm single mode
125 km (77.5 mi)
SC, 1550 nm single mode
125 km (77.5 mi)
NOTE: The SFMFF13xx-28x model is the
stand alone version of the media converter.
For more information, see the user’s guide
on-line at: www.transition.com.
Port One - Duplex Fiber Optic
1000Base-SX
Port Two - Single Mode Fiber-Optic
Single Fiber, 1000Base-LX
2
CFMFF13xx-28x
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
Part Number
CFMFF1329-280
SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX)
20 km (12.4 miles)
CFMFF1329-281
SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm (TX)/1310 nm (RX)
20 km (12.4 miles)
CFMFF1329-280 and CFMFF1329-281 are intended to be
installed in the same network where one is the local converter
and the other is the remote converter.
CFMFF1329-282
SC, 850 nm multimode
220 m (721 ft)**
SC, 1310 nm (TX)/1550 nm (RX)
40 km (24.8 miles)
CFMFF1329-283 SC, 850 nm multimode
220 m (721 ft)**
SC, 1550 nm (TX)/1310 nm (RX)
40 km (24.8 miles)
Unless otherwise indicated, the distances listed are the typical maximum cable
distance. The actual maximum cable distances are dependent upon the physical
characteristics of the network installation. TX = transmit, RX = receive.
** Minimum Cable Distance:
2 meters
Typical Maximum Cable Distance:
220 meters for 160/500MHz•Km
270 meters for 200/500MHz•Km
CFMFF1329-282 and CFMFF1329-283 are intended to be
installed in the same network where one is the local converter
and the other is the remote converter.
Installation
CAUTION: Wear a grounding device and observe electrostatic discharge
precautions when setting the jumper, the 4-position switch, and when installing
the slide-in-module. Failure to observe this caution could result in damage to,
and subsequent failure of, the media converter.
Set the Hardware/Software Jumper
•
The jumper is located on the circuit board.
•
Use small needle-nose pliers to set the recessed switches.
Hardware
The media converter mode is determined by the
4-position switch settings (see page 4).
Software
The media converter mode is determined by the
most-recently saved, on-board microprocessor
settings. (See SNMP on page 6.)
CFMFF1414-280
SC, 1310 nm single mode
10 km (6.2 miles)
SC, 1310 nm single mode
10 km (6.2 miles)
3
[email protected] -- Click the “Transition Now” link for a live Web chat.
Installation -- Continued
Set the 4-position switch
•
The 4-position switch is located on the circuit board.
•
Use a small flat-blade screwdriver to set the recessed switches.
Fiber Auto-Negotiation (Switch 1)
up
= Enable fiber Auto-Negotiation for both the single mode and the
multimode ports.
When fiber Auto-Negotiation is enabled:
The pause feature can be set using switches
3 and 4. (See page 4).
down = Disable fiber Auto-Negotiation for both the single mode and the
multimode ports.
When fiber Auto-Negotiation is disabled:
Switches 3 and 4 will not function. The
media converter adopts the pause setting
from the end device at the other end of the
fiber cable.
NOTE: All devices in the network, including the end devices, must have
Auto-Negotiation enabled, or all devices must have Auto-Negotiation
disabled. Otherwise, the devices in the network will not link up.
Link Pass-Through (Switch 2)
up
= Enable Link Pass-Through.
down = Disable Link Pass-Through.
The Link Pass-Through feature allows the media
converter to monitor both fiber RX (receive) ports for
loss of signal. In the event of a loss of an RX signal
on one media port, the media converter will
automatically disable the TX (transmit) signal of the
other media port, thus, “passing through” the link loss.
No Pause:
•
Pause feature is disabled.
Transmit Only:
•
CFMFF13xx-28x can transmit and the
link partner can receive the pause
signal.
Transmit and Receive:
•
Both the CFMFF13xx-28x and the
link partner can send and receive the
pause signal.
Receive Only:
•
The CFMFF13xx-28x can receive and
the link partner can transmit the
pause signal.
Installation -- Continued
Pause (Switches 3 & 4)
The pause feature can improve network performance by allowing one end of
the link to signal the other to discontinue frame transmission for a set period
of time to relieve buffer congestion.
To properly set the pause feature in the network, the link partner (i.e., the
device to which the CFMFF13xx-28x is linked) must also have comparable
pause switches. If the link partner does not have the pause feature, disable
the pause feature on the CFMFF13xx-28x media converter.
The CFMFF13xx-28x has four pause
options (listed below). To the right of
each option, a drawing shows the switch
settings for the CFMFF13xx-28x and the
link partner.
4
CFMFF13xx-28x
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
5
[email protected] -- Click the “Transition Now” link for a live Web chat.
Install the Fiber Cable
1.
Locate or build IEEE 802.3™ compliant fiber cable with male, two-
stranded TX to RX connectors installed at both ends.
2.
Connect the fiber cables to the CFMFF13xx-28x media converter as
described:
•
Connect the male TX cable connector to the female TX port.
•
Connect the male RX cable connector to the female RX port.
3.
Connect the fiber cables to the other device (another media converter,
hub, etc.) as described:
•
Connect the male TX cable connector to the female RX port.
•
Connect the male RX cable connector to the female TX port.
Installation -- Continued
Install the CFMFF13xx-28x Slide-in-Module
CAUTION: Slots in the PointSystem™ chassis without a slide-in-module
installed MUST have a protective plate covering the empty slot for Class A
and/or Class B compliance.
The media converter slide-in-modules may be installed in any slot, in any
order. To install the CFMFF13xx-28x slide-in-module:
1.
Carefully slide the slide-in-module into the installation slot, aligning the
module’s circuit board with the installation guides.
2.
Ensure that the module is firmly seated inside the chassis.
3.
Push in and rotate the attached panel fastener screw clockwise to secure
the module to the chassis front.
6
CFMFF13xx-28x
24-hour Technical Support: 1-800-260-1312 -- International: 00-1-952-941-7600
SNMP
Use SNMP at an attached terminal or at a remote location to monitor the
media converter by monitoring:
•
Media converter power
•
Single mode fiber link status
•
Multimode fiber link status
•
Hardware/software mode status
Also, use SNMP to enter network commands that:
•
Power up/down the media converter
•
Enable/disable the single mode fiber link
•
Enable/disable the multimode fiber link
•
Enable/disable Auto-Negotiation
•
Enable/disable Link Pass-Through
•
Select pause advertisements
See the on-line documentation that comes with Transition Networks
FocalPoint™ software for applicable commands and usage at
www.transition.com.
Operation
Status LEDs
Use the status LEDs to monitor the media converter operation in
the network.
PWR
On = Connection to external power.
LKS
On = 1000Base-LX (single mode) fiber link is up.
LKM
On = 1000Base-SX (multimode) fiber link is up.
ACT
Flashing = Reception of data on either fiber link.
7
[email protected] -- Click the “Transition Now” link for a live Web chat.
Cable Specifications
The physical characteristics must meet or exceed IEEE 802.3™ specifications.
Single Mode fiber (recommended):
9 µm
Multimode fiber (recommended):
62.5/125 µm
Multimode fiber (optional):
100/140, 85/140, 50/125 µm
Bit error rate:
<10-12
Port 1:
1300 nm multimode
Fiber-optic Transmitter Power:
min: -10.0 dBm
max: -4.0 dBm
Fiber-optic Receiver Sensitivity:
min: -17.0 dBm
max: 0.0 dBm
Link Budget:
7.0 dB
Port 2:
CFMFF1314-280
1310 nm single mode
Fiber-optic Transmitter Power:
min: -13.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -20.0 dBm
max: -3.0 dBm
Link Budget:
7.0 dB
CFMFF1315-280
1310 nm single mode
Fiber-optic Transmitter Power:
min: -5.0 dBm
max: 0.0 dBm
Fiber-optic Receiver Sensitivity:
min: -20.0 dBm
max: -3.0 dBm
Link Budget:
15.0 dB
CFMFF1317-280
1550 nm single mode
Fiber-optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber-optic Receiver Sensitivity:
min: - 23.0 dBm
max: -3.0 dBm
Link Budget:
20.0 dB
CFMFF1324-280
1300 nm extended multimode
Fiber-optic Transmitter Power:
min: -10.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -17.0 dBm
max: -3.0 dBm
Link Budget:
7.0 db
CFMFF1329-280
1310 nm (TX) / 1550 nm (RX) single mode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -21.0 dBm
max: -3.0 dBm
Link Budget:
13.0 dB
CFMFF1329-281
1550 nm (TX) / 1310 nm (RX) single mode
Fiber-optic Transmitter Power:
min: -8.0 dBm
max: -3.0 dBm
Fiber-optic Receiver Sensitivity:
min: -21.0 dBm
max: -3.0 dBm
Link Budget:
13.0 dB
CFMFF1329-282
1310 nm (TX) / 1550 nm (RX) single mode
Fiber-optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -23.0 dBm
max: -8.0 dBm
Link Budget:
20.0 dB
CFMFF1329-283
1550 nm (TX) / 1310 nm (RX) single mode
Fiber-optic Transmitter Power:
min: -3.0 dBm
max: +2.0 dBm
Fiber-optic Receiver Sensitivity:
min: -23.0 dBm
max: -8.0 dBm
Link Budget:
20.0 dB
CFMFF1335-280
1550 nm single mode
Fiber-optic Transmitter Power:
min: 0.0 dBm
max: +5.0 dBm
Fiber-optic Receiver Sensitivity:
min: -32.0 dBm
max: -3.0 dBm
Link Budget:
32.0 db
Pages Preview: