Transition Networks E-FRL-MC03 Manuals

1 pdf manual(s) Transition Networks E-FRL-MC03 for free download (Document Types: Operation & user’s manual)

Transition Networks E-FRL-MC03 Operation & user’s manual [PDF] (2 pages)

  • Identifier: id-297844
  • Brand: Transition Networks
  • Device: E-FRL-MC03 Transceiver
  • Type: PDF
  • Key Aspects: Critical Operational Precautions, Operational Mode Explanations, Cleaning and Sanitization Methods
  • UPD Date: 23.06.2026
  • Source File: 261115.pdf
  • Pages: 2
  • Description: User and installation guide for the Transition Networks E-FRL-MC03.
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Receive Link Power Transmit Collision Jabber SQE On Off Ethernet™ Single Mode FL Transceiver E-FRL-MC03 Mpls, MN 55344 RX TX n e t w o r k s T R A N S I T I O N The Transition Networks Single Mode Fiber Optic Transceiver is used to connect Ethernet IEEE 802.3 AUI (DB-15) nodes to a fiber optic medium using standard ST type connectors (SMA available). The compact size of the transceiver allows a direct connection to most AUI ports on Ethernet compatible workstations, cards, and multiport repeaters. LEDs indicate status of all MAU functions: Jabber, Collision, Transmit, Receive, Link, and Power. An external dip switch turns the SQE heartbeat On and Off. The 1300 nm Single Mode Fiber Optic Transceiver is fully IEEE 802.3 compliant, allowing network managers to utilize multiple components from multiple vendors without compatibility problems. Single Mode Fiber Optic Transceiver E-FRL-MC03 USER’S GUIDE FCC Regulations: Note: This equipment has been tested and found to comply with the limits for a Class A digital device, pursuant to Part 15 of the FCC Rules. These limits are designed to provide reasonable protection against harmful interference when the equipment is operated in a commercial environment. This equipment generates, uses, and can radiate radio frequency energy and, if not used in accordance with the instruction manual, may cause harmful interference to radio communications. Operation of this equipment in a residential area is likely to cause harmful interference in which case the user will be required to correct the interference at his own cost. Canadian Regulations: Note: This digital apparatus does not exceed the Class A limits for radio noise for digital apparatus set out on the radio interference regulations of the Canadian Department of Communications. Copyright Restrictions © 1995, 1997 Transition Networks, Inc. All rights reserved. No part of this work may be reproduced or used in any form or by any means - graphic, electronic, or mechanical - without written permission from Transition Networks, Inc. Trademarks: Ethernet is a registered trademark of the Xerox Corporation, Inc. TRANSITION Networks is a trademark of TRANSITION Networks, Inc. 7358.I Specifications: Case size dimensions: 3.7" x1.75" x 0.8" (94 mm x 44 mm x 20 mm) Standard: Ethernet IEEE 802.3, 1300 nm Fiber Optic Interface Fiber Connection: ST type connectors (SMA type available upon request) Fiber Optic Cable Maximum Distance: 5,000 meters- 20,000 meters Fiber Optic Cable Recommended: 9/125 micron single mode fiber Fiber Optic Transmitter Power: Typical transmit power: -22.5dBm Best case transmit power: -18.5dBm Worst case transmit power:-28.5dBm Fiber Optic Receiver Sensitivity: Best case fiber sensitivity: -35dBm Worst case fiber sensitivity:-30dBm Bit error rate: ≤10-9 Environment: 0–50 degrees C, 10–90% humidity, non-condensing, 0–10,000 foot altitude WARRANTY: FIVE YEARS Minneapolis, MN 55344 USA Status LEDs provide the following information: Transmit: Flashing or illuminated green LED indicates packet(s) are being transmitted. Receive: Flashing or illuminated green LED indicates packet(s) are being received. Link Illuminated green LED indicates the unit is receiving link pulses from a compliant device. Power: Illuminated green LED indicates normal operation. Collision: Flashing or illuminated red LED indicates collisions are occurring. Jabber: Illuminated red LED indicates the unit is disabled. AUI (DB-15) Interface Parameter Minimum Typical Maximum Transmit Transmit threshold voltage level: -140mV -170mV -190mV Transmit turn on delay: 100ns Transmit steady propagation delay: 15ns 50ns Transmit loop back start up delay: 500ns Transmit turn off to data idle: 400ns 2100ns SQE test delay: 0.6 µ sec 1.6 µ sec SQE test duration: 0.5 µ sec 1.0 µ sec 1.5 µ sec Receive Receive turn on delay: 350ns Receive steady propagation delay: 15ns 50ns Differential output voltage (RX(-/+)): (+/-)550mV (+/-)1200 Differential output voltage (col(-/+)): (+/-)550mV (+-)1200 Differential output rise time (RX(-/+), col(-/+)): 4ns Differential output fall time (RX(-/+), col(-/+)): 4ns Collision Time for SQE to deact. after collision: 450ns 700ns Collision frequency: 8.5MHz 11.5MHz Collision pulse duty cycle: 40% 50% 60% SQE test delay: 0.6 µ sec 1.6 µ sec Jabber activation delay: 20ms 70ms 150ms

E-FRL-MC03: Related Instructions

TN-EOT Series
Transition Networks TN-EOT Series
07.04.2026 13 pages

Transition Networks TN-EOT-xx User Guide 33720 Rev. C https://www.transition.com Page 1 of 13 TN-EOT-xx Ethernet over Two-wire Extender SFPs User Guide • Enab Product operation guide for the Transition Networks TN-EOT Series Extender. The manual highlights installation, system parameters, maintenance guidelines.

C4TEF1011-110
Transition Networks C4TEF1011-110
23.03.2026 11 pages

*Typical maximum cable distance. Actual distance is dependent upon the physical characteristics of the network. Installation . . . . . . . . . . . . . . . . . Instruction guide for the Transition Networks C4TEF1011-110 Media Converter. It outlines installation and service instructions, troubleshooting guides, installation steps.

C/F-SM-MM-04
Transition Networks C/F-SM-MM-04
25.03.2026 4 pages

COMPLIANCE INFORMATION UL Listed C-UL Listed (Canada) CISPR/EN55022 Class A FCC Regulations This equipment has been tested and found to comply with the limits f Device setup guide for the Transition Networks C/F-SM-MM-04 Media Converter. It details troubleshooting tips and installation, technical specifications, technical assistance, product safety.

SRS4F3111-100
Transition Networks SRS4F3111-100
25.05.2026 8 pages

USER’S GUIDE SRS4Fxxxx-10x Stand-Alone Media Converter RS485/422 Copper to Fiber Transition Networks SRS4Fxxxx-10x series media converters connect RS485/422 c Complete service manual for the Transition Networks SRS4F3111-100 Media Converter. The guide explains operation and component overview, operating modes, energy usage.

Milan MIL-RC6113SX-V2
Transition Networks Milan MIL-RC6113SX-V2
17.06.2026 16 pages

Raven Series Standalone Media Converters MIL-RC6113SX-V2 -10/100/1000BASE-T / 1000BASE-SX SC MMF MIL-RC6113LX-V2 – 10/100/1000BASE-T / 1000BASE-LX SC SMF MIL- Product operation manual for the Transition Networks Milan MIL-RC6113SX-V2 Media Converter. It describes usage and maintenance, support details, hardware instructions.

SISPM1040-182D
Transition Networks SISPM1040-182D
28.05.2026 157 pages

8 10/100TX + 2 10/100/1000T/Mini-GBIC Combo with 8 PoE Injector Industrial Switch User Manual SISPM1040-182D Version 1.01 October, 2009 Operation and maintenance manual for the Transition Networks SISPM1040-182D Switch. This guide explains the features and security instructions, operating instructions, installation support.

Similar Manuals in the Transceiver Category

TK-2100
Kenwood TK-2100
26.08.2026 40 pages

Product instruction handbook for the Kenwood TK-2100 Transceiver. The documentation includes repair references, network setup, security instructions, usage procedures.

KBPF3
ELECRAFT KBPF3
21.06.2026 15 pages

ELECRAFT® K3 HIGH-PERFORMANCE 160 – 6 METER TRANSCEIVER KBPF3 GENERAL COVERAGE RECEIVE OPTION INSTALLATION INSTRUCTIONS Rev D, June 24, 2008 Copyright © 200 Detailed user guide for the ELECRAFT KBPF3 Transceiver. This documentation details performance guidelines, usage recommendations, operational safety, supported accessories.

ZATRAN
Xantech ZATRAN
23.04.2026 4 pages

- 1 - INSTALLATION INSTRUCTIONS ZATRAN Zone Audio Transceiver DESCRIPTION The ZATRAN is a zone audio transceiver that can be used with one audio/video source. W Product operation manual for the Xantech ZATRAN Transceiver. The guide covers usage and product safety, interface navigation, specifications.

RT-2087/ZPX-A
uAvionix RT-2087/ZPX-A
13.05.2026 48 pages

UAV-1005667-001 Rev A ECCN 7A994 Page 1 | 48 RT-2087/ZPX-A User and Installation Guide Professional operation guide for the uAvionix RT-2087/ZPX-A Transceiver. This guide offers guidance on testing procedures, firmware installation, control functions.