Tyco ELO-231B Series Manuals

2 pdf manual(s) Tyco ELO-231B Series for free download (Document Types: Manual )

Tyco ELO-231B Series Manual  Thumbnail

Tyco ELO-231B Series Manual  [PDF] (6 pages)

  • Identifier: id-1381919
  • Brand: Tyco
  • Device: Tyco ELO-231B Series Irrigation System
  • Type: Manual , PDF
  • Key Aspects: Pre-Installation Safety Requirements, Advanced Configuration Methods, System Limitations and Considerations
  • UPD Date: 22.06.2026
  • Source File: 1345835.pdf
  • Pages: 6
  • Description: Device user manual for the Tyco ELO-231B Series.
Pages Preview:
  • Tyco ELO-231B Series Manual  preview - page 2
  • Tyco ELO-231B Series Manual  preview - page 3
  • Tyco ELO-231B Series Manual  preview - page 4
  • Tyco ELO-231B Series Manual  preview - page 5
  • Tyco ELO-231B Series Manual  preview - page 6
Document Preview & Text Transcription (Main Page)
Click to expand and read text
General Description The 11.2 K-factor, Series ELO-231B, Standard Response, Standard Cover- age, Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprin- klers of the frangible bulb type. They are “standard response - spray sprin- klers” that produce a hemispherical water distribution pattern below the deflector. The 11.2 K-factor, ELO-231B Sprin- klers were subjected to full scale, high- piled storage, fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor stand- ard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231B Sprinklers — making their use highly advantageous in high density applications, such as the protection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy com- ponents used in Series ELO-231B sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- sentative of all possible corrosive at- mospheres. Consequently, it is recom- mended that the end user be consulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The ef- fects of ambient temperature, concen- tration of chemicals, and gas/chemical velocity, should be considered, as a minimum, along with the corrosive na- ture of the chemical to which the sprin- klers will be exposed. An upright intermediate level version of the Series ELO-231B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231B Up- right Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231B Sprinklers can be obtained by utiliz- ing the Series ELO-231B Pendent Sprinkler with the WS-2 Shield. If there is a possibility of the pendent interme- diate level version being exposed to mechanical damage, a G-2 Guard can be added. WARNINGS The 11.2 K-factor, Series ELO-231B Upright and Pendent Sprinklers de- scribed herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association, in addition to the standards of any other authorities hav- ing jurisdiction. Failure to do so may impair the performance of these de- vices. The owner is responsible for maintain- ing their fire protection system and de- vices in proper operating condition. The installing contractor or manufac- turer should be contacted with any questions. Installation of Series ELO-231B Pen- dent Sprinklers in recessed escutch- eons will void all sprinkler warranties, as well as possibly void the sprinkler’s Approvals and/or Listings. Series ELO-231B — 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage Page 1 of 6 TFP342 MARCH, 2007 Technical Services: Tel: (800) 381-9312 / Fax: (800) 791-5500 IMPORTANT Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and in- stallation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely.
Tyco ELO-231B Series Manual  Thumbnail

Tyco ELO-231B Series Manual  [PDF] (6 pages)

  • Identifier: id-1464397
  • Brand: Tyco
  • Device: Tyco ELO-231B Series Irrigation System
  • Type: Manual , PDF
  • Key Aspects: Information on Regular Maintenance, Error Code Explanations, Performance Optimization Tips
  • UPD Date: 17.08.2026
  • Source File: 1534044.pdf
  • Pages: 6
  • Description: Comprehensive user handbook for the Tyco ELO-231B Series.
Pages Preview:
  • Tyco ELO-231B Series Manual  preview - page 2
  • Tyco ELO-231B Series Manual  preview - page 3
  • Tyco ELO-231B Series Manual  preview - page 4
  • Tyco ELO-231B Series Manual  preview - page 5
  • Tyco ELO-231B Series Manual  preview - page 6
Document Preview & Text Transcription (Main Page)
Click to expand and read text
Series ELO-231B – 11.2 K-factor Upright and Pendent Sprinklers Standard Response, Standard Coverage Page 1 of 6 AUGUST 2018 TFP342 IMPORTANT Refer to Technical Data Sheet TFP2300 for warnings pertaining to regulatory and health information. Always refer to Technical Data Sheet TFP700 for the “INSTALLER WARNING” that provides cautions with respect to handling and instal- lation of sprinkler systems and com- ponents. Improper handling and installation can permanently damage a sprinkler system or its compo- nents and cause the sprinkler to fail to operate in a fire situation or cause it to operate prematurely. Worldwide Contacts www.tyco-fire.com General Description TYCO Series ELO-231B 11.2K Standard Response, Standard Coverage Upright and Pendent Sprinklers (Ref. Figure 1) are automatic sprinklers of the frangible bulb type. They are standard response, spray sprinklers that produce a hemi- spherical water distribution pattern below the deflector. The 11.2 K-factor, ELO-231B Sprinklers were subjected to full-scale, high-piled storage fire tests to qualify their use in lieu of 5.6 or 8.0 K-factor standard spray sprinklers for the protection of high-piled storage. Higher flow rates can be achieved at much lower pressures with the 11.2 K-factor, ELO-231B Sprinklers, making their use highly advantageous in high density applications, such as the pro- tection of high-piled storage. Wax or lead coatings can be used to extend the life of the copper alloy components used in Series ELO-231B Sprinklers beyond that which would otherwise be obtained when exposed to corrosive atmospheres. Although wax, lead, and polyester coated sprin- klers have passed the standard corro- sion tests of the applicable approval agencies, the testing is not repre- sentative of all possible corrosive atmospheres. Consequently, it is rec- ommended that the end-user be con- sulted with respect to the suitability of these corrosion resistant coatings for any given corrosive environment. The effects of ambient temperature, concentration of chemicals, and gas/ chemical velocity, should be consid- ered, as a minimum, along with the cor- rosive nature of the chemical to which the sprinklers will be exposed. An upright intermediate level version of the Series ELO-231B Sprinklers for in-rack applications can be obtained by utilizing the Series ELO-231B Upright Sprinkler with the WSG-2 Guard & Shield, and a pendent intermediate level version of the Series ELO-231B Sprinklers can be obtained by utilizing the Series ELO-231B Pendent Sprinkler with the WS-2 Shield. If there is a pos- sibility of the pendent intermediate level version being exposed to mechanical damage, a G-2 Guard can be added. NOTICE The 11.2 K-factor, Series ELO-231B Upright and Pendent Sprinklers described herein must be installed and maintained in compliance with this document, as well as with the applica- ble standards of the National Fire Pro- tection Association (NFPA), in addition to the standards of any other authori- ties having jurisdiction. Failure to do so may impair the performance of these devices. The owner is responsible for main- taining their fire protection system and devices in proper operating con- dition. Contact the installing contrac- tor or product manufacturer with any questions. Installation of Series ELO-231B Pendent Sprinklers in recessed escutcheons will void all sprinkler warranties, as well as possibly void the sprinkler’s Approvals and/or Listings. Sprinkler Identification Numbers (SINs) Refer to Table A for sprinkler identifica- tion numbers.

Similar Manuals in the Irrigation System Category

Device Model Type of Document Pages Size Views Downloads Updated All Manuals for Device
Autopot AQUAvalve5

Autopot AQUAvalve5 Manual (Simple care manuallines), @1S2BIZ

2 810 122 18-05-2026 view all manuals
Autopot 36Pot XL

36Pot XL (Irrigation System ePDF Guide, #QNLA9J)

2 314 48 23-04-2026 view all manuals
Antelco eZyvalve 4

Antelco eZyvalve 4 Manual (Installation manual), @5NIBVE

4 740 178 04-05-2026 view all manuals
Autopot 80 Pot System

Manual: Autopot 80 Pot System (FR4E17, Upd.08-06-2026)

2 1154 266 08-06-2026 view all manuals
Perrot P2M

Perrot P2M Manual (Maintenance and operating instructions), @V7852N

20 1359 232 10-06-2026 view all manuals
Viking MICROFAST VK325

Viking Irrigation System Technical data manual (File: PDF, 15-06-2026)

9 974 234 15-06-2026 view all manuals