Venitem TUL373 Manuals
1 pdf manual(s) Venitem TUL373 for free download (Document Types: Installation manual)
Venitem TUL373 Installation manual [PDF] (4 pages)
- Identifier: id-2297348
- Brand: Venitem
- Device: TUL373 Power Supply
- Type: PDF
- Key Aspects: Cleaning and Sanitization Methods, Additional Modules and Accessories Guide, Model Variations and Compatibility
- UPD Date: 26.04.2026
- Source File: 1990276.pdf
- Pages: 4
- Description: Detailed product documentation for the Venitem TUL373.
Click to expand and read text
MA-AL-T73E-01-03 Manual TUL373EN eng rev3 Rev.3 Page 1 of 4 POWER SUPPLY TUL373 EN CERTIFIED UNI EN54-4:2007. Included updating A1:2002 and A2:2006 Installation Manual GENERAL FEATURES The power supply TUL 373 EN has been designed to be used as power unit with energy stock in the fire security systems in conformity to regulation (EU) No 305/2011. Its electrical and mechanical features make it be conform to the norm EN 54-4:1997 + A1:2002+A2:2006 (Systems for detection and fire indication: Part 4: supplying devices). FUNCTIONAL FEATURES The power supply unit is made by a linear power supply, series adjustment, with serial voltage regulator, limited in constant precision current (rectangular limitation), two 12V 17 Ah batteries (not given within) analogical control circuit and micro-controlled supervision circuit. Supplying is divided on 3 terminal-outputs protected by fuses: BAT: where the back-up battery will be connected OUT 1 and OUT2: for generic charges The charge of the battery occurs at constant tension (27,6 V @ 25°C) with temperature compensation and current limitation. The maximum current supplied by the power supply is 3 A with 2 A for charge and 1 A for the battery. The LED on the control board are close to concerned fuses (see pict.1) and show: - Fuse cut for any of the outputs, with Led off (DL9, DL10) - Current consumed by charge (2 green and one red DL5, DL6, DL7) - Mains presence (DL1 RETE) Check of battery efficiency The power supply periodically carries out the efficiency of the batteries: At first activation of the power supply , the microprocessor will carry out the test of battery presence after about 30 seconds. If connected, the test will be carried out every 10 minutes whilst in case it is not connected, it will continue carry out the test every 20 seconds showing indication FAILURE. During normal functioning, the efficiency of the battery is checked by controlling the batteries tension. If batteries do not manage to maintain an acceptable tension during test, there will be the indication FAILURE. A test of the internal resistance of the battery is carried out during normal functioning, every 1,5 hours (in conformity to attachment EN54-4/A2); if the internal resistance is over 1 ohm, there will be a FAILURE indication. It will then be necessary to replace the batteries and check that terminals and fuses have a good electrical contact. When the battery is replaced, with presence of mains tension, the test of internal resistance is repeated every 5 minutes. A microcontroller system controls various possible anomalies and gives a FAILURE indication in the following conditions: 1. Output Fuses interruptions 2. Overloaded Battery (> 30 V) 3. Low Battery Tension (< 21 V) 4. Power absence and no battery charge 5. Disconnected Battery 6. Internal battery resistance >1 Ώ The indication of failure together with the indication of mains absence are in a connector placed on the control and supervision board. In order to avoid that a possible failure in the series regulator damages the charges or the battery, a protection circuit has been inserted against over-tensions, made of a SCR and a fuse. A fuse for mains alternated supplying is also present. In case of failure in the power supply or of mains missing, supplying of the logic and control circuits occurs by means of battery. . Electrical Specifications Supplying tension 230 Vac +10% / -15% Ac mains frequency 50 Hz sinusoidal Current consumption by mains 1,1 A max. ( full load ) Output tension 27,6 Vdc ( -15% / +10%) Minimum output tension 20 Vdc at max charge, with mains absence and battery discharged Switching-off threshold tension 20 Vdc Output current 3 A max. (see pict.4) Max current for battery recharge 1 A Max current for charges 2 A Regulations towards mains variations at full charge (+10% / -15%) Better than 1% Regulations towards charge variations (0 to 100%) Better than 1% Ripple at full charge 1 Vpp ( at 195,5 Vac ) 30mVpp ( at 253 Vac ) Compensation of output tension according to temperature 4 mV/ K Protection against battery polarity inversion Diode Recommended batteries: 2 x 12 V in series, 17 Ah housing with inflammability class UL-94-V2 or better Type:YUASA NP 17-12 or equivalent. Alarm threshold of battery internal resistance 1Ω Missing mains and failure output relay – dry contacts 25 Vac or 60 Vdc 1A MAX
TUL373: Related Instructions
MA-SE-RIO0-01-03 Manuale Rio eng rev3 Rev.3 Page 1 of 6 INSTALLATION MANUAL SOUNDER MODELS RIO L – RIO LS Official product manual for the Venitem RIO L Marine Equipment. The manual elaborates on features and installation procedures, maintenance procedures, network setup, regulatory notices.
SP200 CARATTERISTICHE TECNICHE TECHNICAL FEATURES CERTIFICAZIONI SP200 SP200 CERTIFICATION SIRENA SUPPLEMENTARE USO INTERNO ADDITIONAL INDOOR SOUNDER Collegar Detailed operating instructions for the Venitem SP200 Security System. The manual describes support details, firmware installation, detailing setup.
EN MANUALE TECNICO TECHNICAL MANUAL IT DOGE WIRELESS AS1 - AS1/P all-guides com Installation guide for the Venitem DOGE AS1 Marine Equipment. It offers guidance for setup and operating modes, setup instructions, wiring setup, operating instructions.
MA-AL-T75E-01-03 Manual TUL375EN eng rev3 Rev.3 Page 1 of 4 POWER SUPPLY TUL375 EN CERTIFIED UNI EN54-4:2007. Included updating A1:2002 and A2:2006 Installat Maintenance instructions for the Venitem TUL375 Power Supply. This manual offers stepwise instructions for usage tips, device calibration, installation procedures, operating guidelines.
MA-SE-RTL0-03-01 Manuale Rialto Triade Lido Eng rev1 Page 1 of 8 INSTALLATION MANUAL SOUNDER MODELS RIALTO L – LS – X – LSX TRIADE L – LS – QL – User operation guide for the Venitem RIALTO L Marine Equipment. This guide elaborates on device features and interface navigation, error handling, hardware setup.
MA-SI-F240-01-04 Manual Mini doge F24 eng rev4 Rev.4 Page 1 of 2 INDOOR FIRE SIREN SUPPLEMENTARY INDOOR SIREN MINI DOGE F24 Features: Mini Doge F24 siren has Product setup manual for the Venitem Mini Doge F24 Security System. This documentation details device reset instructions, installation steps, setup guidelines.
Similar Manuals in the Power Supply Category
Operation and maintenance manual for the Icom IC-PS30 Power Supply. It details troubleshooting tips and firmware updates, usage procedures, technical overview, support details.
ENGINEERED TO ENTERTAIN Device setup guide for the Cyrus PSX-R2 Power Supply. The document contains usage procedures, product safety, hardware instructions, installation support.
DS 1060-174 LBT 21017 Mod. 1083 AAAAAAAAAAAA SOFTWARE PER VIDEOCITOFONO IP PER PC WINDOWS IPERCOM CLIENT SOFTWARE FOR WINDOWS PC INTERASCOTFITVWARE VOOR IP VIDE Product usage guide for the urmet domus 1083 Intercom System. The document elaborates on device functions and product specifications, hardware components, operation, backup procedures.
1 Owner’s Manual Backup Power Block Model: AV550SC Series Number: AGBC6650 Not suitable for mobile applications. Español 9 • Français 17 1111 W. 35th Stre Practical user guide for the Tripp Lite AGBC6650 UPS. It covers topics such as backup procedures, performance details, operating modes.